Broan-NuTone 353
Broan-NuTone 353 Gable Mount Attic and Garage Ventilation Fan User Manual
Eredua: 353
1. Produktua amaitu daview
The Broan-NuTone 353 Powered Attic and Garage Ventilation Fan is designed to prevent heat and moisture buildup in attics and garages. Proper ventilation helps maintain a cooler, drier environment, which can extend the lifespan of your roof and air conditioning system, while also reducing energy costs. This fan is suitable for ventilating one, two, or three-car garages, whether attached or detached from the home, effectively combating heat, humidity, and unwanted odors.
Ezaugarri nagusiak hauek dira:
- Gable Mount Installation: Specifically designed for gable installation, requiring permanent electrical wiring and grounding. Extension cords must not be used.
- Eragiketa eraginkorra: Delivers 760 Cubic Feet Per Minute (CFM) of airflow. Features a precision-balanced 14-inch metal blade for maximum air movement.
- Eraikuntza iraunkorra: Constructed with galvanized steel housing for enhanced strength and longevity.
- Kontrol automatikoa: Equipped with an adjustable, built-in thermostat for automatic operation based on temperature.
- Neurriak: Housing measures 15 inches in diameter and 8 inches deep, with a 14-inch diameter steel blade.

Image 1.1: Broan-NuTone 353 Gable Mount Attic and Garage Ventilation Fan. This image shows the complete fan unit, highlighting its robust construction and blade design.
2. Segurtasun informazioa
OHARRA: Sutea, deskarga elektrikoa edo pertsonei lesio arriskua murrizteko, kontuan hartu honako hau:
- Instalazio-lanak eta kableatu elektrikoak pertsona kualifikatuek egin behar dituzte aplikagarriak diren kode eta estandar guztien arabera, suaren aurkako eraikuntza-kode eta estandarrak barne.
- Deskonektatu beti zerbitzu-paneleko korrontea unitatea kableatu edo konpondu aurretik.
- This unit requires permanent electrical wiring and grounding. Do not use with an electrical extension cord.
- This product is intended for gable installation only.
- Kaliforniako 65 Proposamenaren abisua: Produktu honek Kaliforniako Estatuak minbizia, jaiotza-akatsak edo ugalketa-kalte batzuk eragiten dituen produktu kimikoak izan ditzake.
3. Konfigurazioa eta instalazioa
Proper installation is crucial for the efficient and safe operation of your Broan-NuTone 353 fan. This fan is designed for gable mounting. Ensure you have adequate soffit ventilation to allow for proper airflow.
3.1. Instalazio aurreko gogoetak
- Aireztapen-baldintzak: Calculate the required Cubic Feet Per Minute (CFM) for your attic or garage. A general guideline is to multiply the attic volume (Length x Width x Height) by 10 air changes per hour, then divide by 60 minutes/hour to get CFM. Ensure sufficient soffit vent area (approximately 0.48 square inches per CFM).
- Kableatu elektrikoa: The fan requires permanent 120-volt AC electrical wiring and proper grounding. Consult a qualified electrician if you are unsure about electrical connections.
- Muntatzeko kokapena: Identify a suitable gable vent opening. The fan housing is 15 inches in diameter.

Image 3.1: Ventilation Calculation Guide. This image provides a step-by-step guide to calculate the recommended CFM and minimum soffit vent area for effective ventilation.
3.2. Haizagailua muntatzea
The fan is typically mounted to a wooden frame constructed around the gable vent opening. This frame provides a secure and stable base for the fan.
- Prepare the Mounting Board: Cut a piece of plywood (e.g., 21 inches square) to fit securely within the gable vent framing. Trace the fan's duct shape onto the plywood and cut out the opening.
- Pre-wire the Fan: Before mounting, connect 14/2 electrical wire to the fan's junction box. This makes wiring easier than doing it in a confined attic space.
- Secure the Fan to the Board: Center the fan on the prepared plywood board. Use 1/2-inch wood screws for the inner mounting holes and 1 1/2-inch wood screws for the outermost holes, ensuring they penetrate into the studs of the frame.
- Install the Assembly: Position the fan and plywood assembly into the gable vent opening. Secure it to the existing attic framing (e.g., 2x4s) using screws. Start with a few screws to support the unit, then add more to ensure it is very secure.
- Run Electrical Wiring: Route the electrical wire from the fan along the attic ridge to your power source (e.g., an existing outlet converted to a switch). Secure the wire with tacks every few feet.
- Konektatu energiara: Wire the fan to a dedicated switch or power source according to local electrical codes.

Image 3.2: Gable Mount Fan Installation. This image illustrates the Broan 353 fan mounted within a wooden frame in a gable vent opening, showing the electrical connection box.

Image 3.3: Fan Blade and Housing Dimensions. This image provides a visual reference for the fan's dimensions, including the 16-inch overall diameter and 14-inch blade.
4. Funtzionamendu-argibideak
The Broan-NuTone 353 fan operates automatically via its built-in adjustable thermostat.
- Piztu: Ensure the fan is connected to a permanent power source and the wall switch (if installed) is in the "ON" position.
- Termostatoaren doikuntza: The thermostat is located within the fan shroud. It controls when the fan activates based on the attic or garage temperature.
- To adjust the temperature setting, access the thermostat and rotate the dial to your desired activation temperature.
- Consider that the thermostat inside the shroud may register a slightly lower temperature than the overall attic temperature due to its proximity to the gable vent and airflow. You may need to set it lower than your desired attic temperature to achieve optimal operation.
- Common settings range from 90°F to 110°F (32°C to 43°C).
- Funtzionamendu automatikoa: Once set, the fan will automatically turn on when the temperature at the thermostat reaches the set point and turn off when the temperature drops below it.
5. Mantentzea
Regular maintenance helps ensure the longevity and efficient operation of your ventilation fan.
- Urteko ikuskapena: Annually, or more frequently in dusty environments, inspect the fan blades and motor for dust and debris buildup.
- Garbiketa: Disconnect power to the fan at the circuit breaker before cleaning. Use a soft cloth or brush to gently remove any accumulated dust or dirt from the blades and motor housing. Do not use water or liquid cleaners directly on electrical components.
- Begiratu oztoporik dagoen: Ensure the gable vent opening and fan blades are free from obstructions such as bird nests, leaves, or other debris.
- Motoren lubrifikazioa: The fan motor is typically permanently lubricated and does not require additional oiling. Refer to the motor's specific instructions if available.
6. Arazoak
If your Broan-NuTone 353 fan is not operating as expected, refer to the following common issues and solutions:
| Arazoa | Kausa posiblea | Irtenbidea |
|---|---|---|
| Haizagailua ez da pizten. |
|
|
| Fan is excessively noisy or vibrates. |
|
|
| Fan runs constantly. |
|
|
7. Zehaztapenak
| Ezaugarri | Xehetasuna |
|---|---|
| Marka | Broan-NuTone |
| Ereduaren izena | 353 |
| Muntatze Mota | Gable Mount |
| Aire Fluxuaren Ahalmena | 760 CFM (minutuko oin kubikoak) |
| liburukiatage | 120 Volt |
| Wattage | 60 watt |
| Abiadura | 1030 RPM |
| Zarata Maila | 14.4 dezibelio |
| Produktuaren neurriak (L x W x H) | 15"D x 1"W x 8"H (Housing) |
| Pala Diametroa | 14 hazbetekoa |
| Materiala | Galvanized Steel (Housing), Metal (Blade) |
| Ezaugarri Berezia | Adjustable Built-in Thermostat |
| Energia iturria | AC |
| Elementuaren pisua | 11.1 kilo |
| UPC | 026715001538 |
8. Bermea eta Laguntza
For warranty information, technical support, or to purchase replacement parts, please contact Broan-NuTone customer service or visit their official webgunea. Gorde erosketa-agiria erosketaren frogagiri gisa berme-erreklamazioetarako.
Broan-NuTone Ofiziala Webgunea: www.broan-nutone.com
Ask a question about this manual