Watts 009M2 Reduced Pressure Zone Backflow Preventer (Model 0063010) Instruction Manual

For Models: 009M2, 009M2-QT

1. Sarrera

This manual provides detailed instructions for the installation, operation, and maintenance of the Watts 009M2 Reduced Pressure Zone (RPZ) Backflow Preventer. This device is designed to protect potable water supplies from contamination due to backpressure or backsiphonage from non-potable sources. It is crucial to read and understand all instructions before installation and use to ensure proper function and safety.

The Watts 009M2 RPZ assembly features a compact, modular design for easy maintenance, with a single access cover for in-line repairs. It is suitable for continuous pressure piping applications and cross-connections identified as health hazards.

2. Segurtasun informazio garrantzitsua

3. Produktua amaitu daview eta Osagaiak

The Watts 009M2 Reduced Pressure Zone Backflow Preventer is constructed with a durable bronze body and features NPT end connections. Key components include:

Watts 009M2 Reduced Pressure Zone Backflow Preventer
Figure 1: Watts 009M2 Reduced Pressure Zone Backflow Preventer. This image shows the bronze body, quarter-turn shutoff valves with green handles, and multiple test cocks on top.

4. Konfigurazioa eta instalazioa

  1. Instalazio aurreko egiaztapena:
    • Verify that the product model (009M2) and size (2 inch) match your requirements.
    • Egiaztatu unitatea bidalketa-kalterik dagoen.
    • Ensure all necessary tools and materials for installation are available.
  2. Gunearen prestaketa:
    • Choose an installation location that allows for easy access for testing and maintenance.
    • Ensure adequate drainage for the relief valve discharge.
    • The device should be installed horizontally, with the relief valve pointing downwards.
  3. Hodiaren konexioa:
    • Flush the upstream piping thoroughly to remove any debris before connecting the backflow preventer.
    • Connect the inlet and outlet piping to the NPT connections on the device. Use appropriate thread sealant.
    • Avoid overtightening connections to prevent damage to the bronze body.
    • Ensure the flow arrow on the device body matches the direction of water flow.
  4. Relief Valve Drain:
    • Connect a drain line to the relief valve outlet. The drain line must be adequately sized and sloped to allow for free discharge and prevent backpressure on the relief valve.
    • Ensure the drain line terminates in an air gap, preventing any possibility of cross-connection.
  5. Instalazio osteko egiaztapena:
    • Slowly open the upstream shutoff valve, then the downstream shutoff valve, to gradually fill the system and prevent water hammer.
    • Ikuskatu konexio guztiak ihesak ikusteko.
    • Perform initial testing by a certified backflow prevention tester to ensure proper operation and compliance with local codes.

5. Funtzionamendu-argibideak

The Watts 009M2 is designed for continuous pressure operation. Normal operation involves the device being fully open, allowing water to flow through the system while providing backflow protection.

6. Mantentzea

Regular maintenance is critical for the reliable performance of your backflow preventer. The modular design and single access cover simplify servicing.

7. Arazoak

ArazoaKausa posibleaIrtenbidea
Water discharge from relief valve (continuous)
  • Fouled first check valve
  • Damaged relief valve seat or disc
  • Excessive backpressure
  • Clean or repair first check valve.
  • Inspect and replace relief valve components.
  • Identify and correct source of backpressure.
Ur-fluxurik ez edo emari murriztua
  • Shutoff valves closed
  • Debris obstructing flow
  • Fouled check valves
  • Ensure shutoff valves are fully open.
  • Isolate and inspect for debris.
  • Clean or repair check valves.
Konexioetatik ihesak.
  • Gaizki zigilatutako hariak
  • Damaged gaskets
  • Re-apply thread sealant and tighten connections.
  • Junturak ikuskatu eta ordezkatu.

For issues not listed or if troubleshooting steps do not resolve the problem, contact a certified plumbing professional or Watts technical support.

8. Zehaztapenak

Modelo zenbakia0063010 (009M2)
Backflow Preventer TypePresio murriztuko guneen muntaia
Gorputzaren MaterialaBrontzea
Inlet/Outlet Connection Size2 Inches (50 MM)
Inlet/Outlet Connection TypeFemale Threaded NPT
Laneko Gehienezko Presioa175 PSI (12.10 BAR)
Tenperatura maximoa180 °F (82 °C)
Tenperatura minimoa33 °F (0.5 °C)
Babes motaBackpressure and Backsiphonage
Produktuaren neurriak (L x W x H)22 x 10 x 8 hazbete
Elementuaren pisua27 kilo
Lead Free StatusNO (For non-potable use only)

9. Bermea eta Laguntza

Specific warranty information for Watts products is typically provided with the product packaging or available on the official Watts webgunea. Mesedez, kontsultatu baliabide hauek bermearen baldintza eta zehaztapen eguneratuenak ikusteko.

For technical support, replacement parts, or further assistance, please contact Watts customer service or visit their official website. Ensure you have your product model number (0063010) and serial number (if applicable) ready when contacting support.

Watts Official Webgunea: www.watts.com

Erlazionatutako dokumentuak - 0063010

Aurreview Watts LF909 Series Reduced Pressure Zone Assembly Engineering Specification
Comprehensive engineering specification for the Watts LF909 Series Reduced Pressure Zone Assembly (21⁄2" - 10"). Details features, operation, materials, dimensions, and capacity for this Lead Free backflow prevention device with integrated flood sensor.
Aurreview Watts Series 009, LF009, LFU009, SS009, U009: Installation, Maintenance, and Repair Manual
This comprehensive manual from Watts provides essential guidance for the installation, maintenance, and repair of the Series 009, LF009, LFU009, SS009, and U009 Reduced Pressure Zone Assemblies. It details safety warnings, installation procedures, inspection, servicing, troubleshooting, and warranty information for these critical backflow prevention devices.
Aurreview Watts Series 909, LF909, 909RPDA Reduced Pressure Zone Assemblies Installation, Maintenance, and Repair Manual
Comprehensive guide for the installation, maintenance, and repair of Watts Series 909, LF909, and 909RPDA Reduced Pressure Zone Assemblies, including safety warnings, installation guidelines, testing procedures, servicing instructions, troubleshooting, and warranty information.
Aurreview Watts Serieko LF909 Presio Murriztuko Eremu Muntaketak - Zehaztapen Teknikoak
Watts Serieko LF909 Presio Murriztuko Eremu Muntaketen zehaztapen tekniko zehatzak, ezaugarriak, funtzionamendua, neurriak, pisuak eta edukiera barne. Edateko uraren gurutzaketa-konexioen kontrola egiteko diseinatua.
Aurreview Watts Series 009, LF009, LFU009, SS009, U009 Reduced Pressure Zone Assemblies Installation, Maintenance, and Repair Manual
Comprehensive guide for the installation, maintenance, and repair of Watts Series 009, LF009, LFU009, SS009, and U009 Reduced Pressure Zone Assemblies, covering safety, installation procedures, annual inspection, troubleshooting, and service. Includes details on flood sensor activation and connection kits.
Aurreview Watts Series LF919 Reduced Pressure Zone Assembly: Installation, Maintenance, and Repair Manual
Comprehensive guide for installing, maintaining, and repairing the Watts Series LF919 Reduced Pressure Zone Assembly (1/2" - 2"). Includes safety warnings, installation procedures, servicing instructions, and troubleshooting.