This manual provides detailed instructions for the installation, operation, and maintenance of the KOHLER GP1068030 Fill Valve. This genuine Kohler part is designed specifically for low-profile one-piece toilets with flex connections, including models such as San Raphael, Rialto, and Revival. Please read these instructions thoroughly before beginning installation to ensure proper function and safety.
2. Segurtasun informazioa
- Always turn off the water supply to the toilet before attempting any installation or maintenance.
- Instalazioan zehar, erabili babes pertsonaleko ekipamendu egokia, hala nola eskularruak eta begien babesgarriak.
- Ziurtatu konexio guztiak ondo finkatuta daudela ihesak saihesteko.
- Urrats baten inguruan ziur ez bazaude, kontsultatu iturgin kualifikatu bati.
- This product is intended for use with potable water systems only.
3. Produktua amaitu daview
The KOHLER GP1068030 Fill Valve is a replacement part for specific Kohler one-piece toilets. It is constructed from durable plastic and designed for efficient water filling.
3.1 Barne dauden osagaiak
- KOHLER GP1068030 Fill Valve Assembly
- Mounting Nut and Washer

Image 1: The KOHLER GP1068030 Fill Valve assembly, showing its main components including the float, shank, and adjustment screw.

Image 2: The KOHLER GP1068030 Fill Valve as it appears in its retail packaging, highlighting it as a genuine Kohler part.
4. Konfigurazioa eta instalazioa
Follow these steps to replace your existing fill valve with the KOHLER GP1068030. Ensure the water supply is turned off before proceeding.
- Itzali uraren hornidura: Locate the shut-off valve for your toilet, typically on the wall or floor behind the toilet, and turn it clockwise until the water flow stops completely.
- Komuneko hustubidea: Komuneko ura hustu depositua husteko. Eutsi hustugailuaren heldulekuari ahalik eta ur gehien hustutzeko.
- Kendu gainerako ura: Use a sponge or towel to remove any remaining water from the toilet tank.
- Deskonektatu ur-hornikuntza hodia: Unscrew the water supply line from the bottom of the old fill valve. Have a small bucket ready to catch any residual water.
- Kendu betegarri-balbula zaharra: Loosen and remove the large nut on the underside of the toilet tank that secures the old fill valve. Carefully lift the old fill valve out of the tank.
- Betetze-balbula berria instalatu: Insert the new KOHLER GP1068030 Fill Valve into the hole at the bottom of the toilet tank. Ensure the rubber washer is properly seated on the shank inside the tank.
- Secure New Fill Valve: From the underside of the tank, thread the plastic mounting nut onto the shank of the new fill valve. Hand-tighten the nut firmly. Do not overtighten, as this can damage the plastic components.
- Ur-hornikuntzako linea konektatu: Reconnect the water supply line to the bottom of the new fill valve. Hand-tighten, then use a wrench to gently tighten an additional quarter turn. Avoid overtightening.
- Uraren hornidura piztu: Slowly turn the water supply valve counter-clockwise to restore water flow to the toilet. Check for any leaks at the connections.
- Egiaztatu ihesak: Observe the fill valve and connections for several minutes to ensure there are no leaks.
5. Funtzionamendua
The fill valve automatically refills the toilet tank after each flush. The water level is adjustable to optimize flushing performance and water usage.
5.1 Adjusting Water Level
The water level in the toilet tank can be adjusted using the screw located at the top of the fill valve. This adjustment controls the height of the float, which in turn determines when the fill valve shuts off.
- To altxatu the water level: Turn the adjustment screw clockwise with a Phillips head screwdriver.
- To beherago the water level: Turn the adjustment screw counter-clockwise with a Phillips head screwdriver.
- Adjust the water level so it is approximately 1 inch below the top of the overflow tube, or to the water line marked inside your toilet tank.

Image 3: The KOHLER GP1068030 Fill Valve illustrating its approximate dimensions, useful for confirming fit within the toilet tank.
6. Mantentzea
Regular maintenance helps ensure the longevity and optimal performance of your fill valve.
6.1 Ohiko garbiketa
Over time, mineral deposits can accumulate inside the fill valve, potentially affecting its performance. The GP1068030 fill valve is designed for easy cleaning.
- Itzali uraren hornidura: Itzali komuneko ur-hornidura.
- Komuneko hustubidea: Komuna garbitu depositua husteko.
- Disassemble Valve Top: Gently twist the top cap of the fill valve counter-clockwise to remove it.
- Ikuskatu eta garbitu: Inspect the rubber diaphragm and internal components for mineral buildup or debris. Rinse components under running water. For stubborn deposits, a soft brush or a mild descaling solution can be used.
- Balbula berriro muntatu: Carefully reassemble the valve, ensuring the diaphragm is correctly seated and the top cap is securely twisted back into place.
- Ur hornidura berreskuratu: Turn the water supply back on and check for proper operation and leaks.
7. Arazoak
| Arazoa | Kausa posiblea | Irtenbidea |
|---|---|---|
| Komuna etengabe dabil edo txandaka piztu eta itzali. | Water level too high, float obstructed, or debris in valve. | Adjust water level (see Section 5.1). Check for obstructions around the float. Clean the fill valve (see Section 6.1). |
| Toilet fills slowly. | Low water pressure, clogged water supply line, or debris in valve. | Check household water pressure. Ensure water supply valve is fully open. Clean the fill valve (see Section 6.1). |
| Water leaks from tank bottom. | Loose mounting nut or damaged washer. | Ensure mounting nut is hand-tightened. Inspect and replace washer if damaged. |
8. Zehaztapenak
- Modelo zenbakia: GP1068030
- Marka: Kohler
- Materiala: Plastikoa
- Produktuaren neurriak: Gutxi gorabehera 15.5 x 6.38 x 2.31 hazbete (39.4 x 16.2 x 5.9 cm)
- Instalazio mota: Floor Mounted (referring to the toilet type, not the valve itself)
- Ziurtagiriak: ASME, ANSI, OSHA, UPC, IAPMO (as per product data)
- UPC: 885612353276
9. Bermea eta laguntza
As a KOHLER Genuine Part, the GP1068030 Fill Valve is designed and manufactured to Kohler's high standards, ensuring compatibility and performance with Kohler products. Using genuine parts helps protect the warranty of your Kohler toilet.
For specific warranty details or technical support, please refer to the official Kohler website or contact Kohler customer service directly. Contact information can typically be found on the Kohler website or in the documentation provided with your original toilet fixture.
Sareko baliabideak: www.kohler.com/serviceparts
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.