1. Produktua amaitu daview

This document provides instructions for the installation and use of the Porter Cable 5140112-36 OEM Replacement Trigger. This trigger is a genuine Porter Cable replacement part, supplied new and bulk packed, designed to restore functionality to compatible power tools.

It replaces obsolete part numbers A22746 and 849317.

Porter Cable 5140112-36 OEM Replacement Trigger

Image: The Porter Cable 5140112-36 OEM Replacement Trigger, a black plastic component with electrical contacts, designed for power tools.

2. Bateragarritasuna

This replacement trigger is compatible with the following Porter Cable belt sander models:

  • Porter Cable 352 Type 1 3x21 Belt Sander
  • Porter Cable 352 Type 2 3x21 Belt Sander
  • Porter Cable 352 Type 3 3x21 Belt Sander
  • Porter Cable 352 Type 4 3x21 Belt Sander
  • Porter Cable 352 Type 5 3x21 Belt Sander
  • Porter Cable 337 Type 1 3x21 Belt Sander
  • Porter Cable 336 Type 1 3x21 Belt Sander
  • Porter Cable 351 Type 1 3x21 Belt Sander
  • Porter Cable 351 Type 2 3x21 Belt Sander
  • Porter Cable 351 Type 3 3x21 Belt Sander
  • Porter Cable 351 Type 4 3x21 Belt Sander
  • Porter Cable 351 Type 5 3x21 Belt Sander
  • Porter Cable 352VS Type 1 3x21 Variable Speed Belt Sander
  • Porter Cable 352VS Type 2 3x21 Variable Speed Belt Sander
  • Porter Cable 352VS Type 3 3x21 Variable Speed Belt Sander
  • Porter Cable 352VS Type 4 3x21 Variable Speed Belt Sander
  • Porter Cable 352VS Type 5 3x21 Variable Speed Belt Sander
  • Porter Cable 352VS Type 6 3x21 Variable Speed Belt Sander

Always consult your tool's owner's manual for proper part number identification and installation procedures specific to your model.

3. Instalatzeko jarraibideak

Safety Warning: Always ensure the power tool is unplugged from the power source before attempting any repairs or part replacements to prevent electric shock or injury.

A screwdriver is typically required for this replacement.

  1. Deskonektatu energia: Ziurtatu tresna elektrikoa entxufe elektrikotik deskonektatuta dagoela.
  2. Etxebizitza Irekia: Remove the screws that hold the two pieces of the tool's housing together. Carefully separate the housing halves.
  3. Kendu etengailu zaharra: Disconnect the wires from the old switch and remove it from the housing. Note the orientation and connection points of the wires for correct reinstallation.
  4. Instalatu etengailu berria: Place the new 5140112-36 trigger switch into the housing.
  5. Konektatu kableak: Connect the wires to the new switch, ensuring they are securely attached to the correct terminals.
  6. Etxebizitza berriro muntatu: Carefully reassemble the tool's housing, ensuring all wires are tucked away and not pinched. Secure the housing with the screws.
  7. Proba funtzionaltasuna: Plug in the tool and test the new trigger switch for proper on/off and variable speed operation.

4. Funtzionamendu funtzionala

The Porter Cable 5140112-36 replacement trigger switch is a common component in power tools, designed for reliable operation. It is a suspension trigger switch featuring a large push button for ease of use.

This trigger handles both the on/off control and variable speed functions of your power tool, allowing for precise control during operation. Additionally, it incorporates a power-off feature that instantly reverses electrical polarity, contributing to the tool's overall safety and performance.

Video: Demonstration of a power tool trigger switch's function, illustrating its on/off, variable speed, and polarity reversal capabilities.

5. Mantentzea

The Porter Cable 5140112-36 OEM Replacement Trigger is a sealed electrical component and does not require routine maintenance. If the switch exhibits signs of wear, damage, or malfunction, it should be replaced immediately to ensure safe operation of the power tool.

6. Arazoak

If the power tool does not operate correctly after installing the new trigger switch, consider the following:

  • Potentzia-konexioa: Ensure the tool is properly plugged into a functional power outlet.
  • Hari-konexioak: Verify that all wires are securely connected to the correct terminals on the new switch. Loose or incorrect connections can prevent operation.
  • Tool Housing: Check that the tool's housing is correctly reassembled and no wires are pinched or obstructing internal components.
  • Beste osagai batzuk: If the switch is correctly installed and the tool still does not function, the issue may lie with another component of the power tool. Consult a qualified technician or the tool's service manual.

7. Zehaztapenak

EzaugarriXehetasuna
FabrikatzaileaPorter Kablea
Zati zenbakia514011236
Elementuaren pisua1.28 ontza
Produktuaren neurriak2 x 2 x 3.5 hazbete
Elementuaren eredu-zenbakia514011236
Elementu pakete kopurua1
ASINB00BFDKFQU
Eskuragarri dagoen lehen data13ko otsailaren 2013a

8. Bermea eta Laguntza

For warranty information regarding the Porter Cable 5140112-36 OEM Replacement Trigger, please refer to the original purchase documentation or contact the seller directly. Support for Porter Cable products can also be found on the official Porter Cable webgunea bisitatuz edo PORTER-CABLE Store on Amazon.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.