1. Sarrera
The Inogen One G3 External Battery Charger (Model BA-303) is designed to provide a convenient and efficient method for charging Inogen One G3 standard and extended batteries independently of the Inogen One G3 portable oxygen concentrator. This manual provides essential information for the safe and effective use of your charger.

Image: The Inogen One G3 External Battery Charger with an Inogen One G3 battery inserted, ready for charging.
2. Segurtasun informazioa
Please read all safety instructions before using the Inogen One G3 External Battery Charger. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Use only with Inogen One G3 standard (BA-300) and extended (BA-316) batteries.
- Ez jarri kargagailua uraren edo gehiegizko hezetasunaren eraginpean.
- Ez saiatu kargagailua desmuntatzen edo aldatzen.
- Ensure the charger is connected to a compatible electrical outlet (100-240V AC, 50-60Hz).
- Mantendu kargagailua bero-iturrietatik eta eguzki-argitik urrun.
- If the charger or power cord is damaged, discontinue use immediately and contact customer support.
Lege-oharra: Statements regarding dietary supplements have not been evaluated by the FDA and are not intended to diagnose, treat, cure, or prevent any disease or health condition. This product is an accessory for a medical device.
3. Paketearen edukia
Egiaztatu elementu guztiak paketean daudela:
- Inogen One G3 External Battery Charger (Model BA-303)
- AC sarrerako kablea
4. Bateragarritasuna
This external battery charger is specifically designed for use with Inogen One G3 batteries. It supports both the standard (BA-300) and extended (BA-316) Inogen One G3 battery models.

Image: An accessory compatibility chart showing the Inogen One G3 External Battery Charger (BA-303) is compatible with Inogen One G3 Standard (BA-300) and Extended (BA-316) batteries.
5. Konfiguratzeko argibideak
Follow these steps to set up your Inogen One G3 External Battery Charger:
- Konektatu AC Power: Plug the AC input cord into an electrical outlet.

Image: Step 1 of the charging process, showing the AC power cord being plugged into a wall outlet.
- Kargagailura konektatu: Plug the other end of the AC input cord into the designated port on the external battery charger.

Image: Step 2 of the charging process, illustrating the AC power cord connected to the external battery charger.
- Sartu bateria: Slide your Inogen G3 battery onto the charger until it clicks and locks into place. Ensure it is seated correctly.

Image: Step 3 of the charging process, showing an Inogen G3 battery being slid onto the charger until it locks.
6. Funtzionamendu-argibideak
Once the charger is set up and a battery is inserted, the charging process will begin automatically.
Karga-adierazleak
- Argi gorri sendoa: When the battery is correctly positioned on the charger, a solid red light will illuminate, indicating that the battery is actively charging.

Image: Step 4 of the charging process, showing the charger with a solid red light, indicating the battery is charging.
- Argi berdea: When the green light illuminates, the battery is fully charged and ready for use.

Image: Step 5 of the charging process, showing the charger with a green light, indicating the battery is fully charged.
Kargatzeko Denborak
Approximate charging times are as follows:
- Standard Inogen One G3 Battery: Up to 5 hours
- Extended Inogen One G3 Battery: Up to 8 hours

Image: The Inogen One G3 External Battery Charger with a battery, illustrating the approximate charging times for standard and extended batteries.
For continuous use, consider having multiple batteries and an additional external charger to ensure batteries are always ready.
7. Mantentzea
The Inogen One G3 External Battery Charger requires minimal maintenance.
- Keep the charger clean and free from dust. Wipe with a dry, soft cloth.
- Ez erabili garbitzaile likidorik edo material urratzailerik.
- Gorde kargagailua leku fresko eta lehor batean erabiltzen ez duzunean.
- Inspect the power cord regularly for any signs of damage.
8. Arazoak
Kargagailuarekin arazoak badituzu, jo ezazu honako arazo eta irtenbide ohikoenei:
| Arazoa | Kausa posiblea | Irtenbidea |
|---|---|---|
| Charger light not illuminating | No power to charger, battery not inserted correctly, or charger malfunction. |
|
| Argi gorria keinuka | Error during charging process. |
|
| Bateria ez da guztiz kargatzen | Battery issue or charger malfunction. |
|
9. Zehaztapenak
| Ezaugarri | Xehetasuna |
|---|---|
| Modelo zenbakia | BA-303 |
| Bateragarritasuna | Inogen One G3 Standard (BA-300) and Extended (BA-316) Batteries |
| Sarrera boltage | 100-240V AC, 50-60Hz |
| Irteera boltage | 15 Volt |
| Neurriak (W x L x H) | 3.3 hazbeteko x 2.75 hazbeteko x 1 hazbeteko |
| Pisua | 0.12 kilo. (gutxi gorabehera) |
| Standard Battery Charge Time | Gehienez 5 ordu |
| Extended Battery Charge Time | Gehienez 8 ordu |
10. Bermea eta Laguntza
For warranty information and customer support, please refer to the documentation provided with your original Inogen One G3 portable oxygen concentrator or visit the official Inogen webgunea.
Era berean, bisitatu dezakezu Inogen Store on Amazon produktuari eta osagarriei buruzko informazio gehigarria lortzeko.