This instruction manual provides essential information for the safe and effective use of your OSRAM HMI DIGITAL 1200 W metal halide lamp. Please read this manual thoroughly before installation and operation, and retain it for future reference. This lamp is designed for professional applications in studio, stage, and television lighting.

2. Segurtasun informazioa

OHARRA: HMI lamps operate under high internal pressure and produce intense UV radiation and high luminance. Failure to follow safety guidelines can result in serious injury or property damage.

  • Always operate this lamp exclusively in enclosed lamp casings specifically designed for HMI lamps.
  • Ziurtatu lamp casing provides adequate UV protection.
  • Ez ukitu lamp esku hutsez. Larruazaleko olioek puntu beroak sor ditzakete eta l murriztuamp life. Use clean gloves during handling.
  • Onartu lamp to cool completely before handling or attempting replacement.
  • l-ren kasuanamp breakage, mercury may be released. Follow local regulations for cleanup and disposal. Avoid direct contact with broken lamp zatiak.
  • Instalazioa eta mantentze-lanak langile kualifikatuek bakarrik egin behar dituzte.
  • Ensure the power supply matches the lamp's nominal voltage eta wattage.

3. Produktua amaitu daview

OSRAM HMI DIGITAL 1200 W metal halide lamp with G38 base

1. irudia: OSRAM HMI DIGITAL 1200 W Lamp. This image displays the OSRAM HMI DIGITAL 1200 W lamp. It features a clear glass envelope revealing the internal arc tube and electrodes, mounted on an orange ceramic G38 base with two metal pins for electrical connection. The base is labeled with 'OSRAM HMI DIGITAL 1200W' and 'MADE IN CZECH REPUBLIC'.

3.1 Ezaugarri nagusiak

  • High Color Rendering Index (CRI) of >90 for accurate color reproduction.
  • UV-Stop (UVS) technology to minimize harmful UV emissions.
  • Color temperature of approximately 6,000 K, simulating natural daylight.
  • Extremely high luminous efficacy of up to 100 lumens per watt.
  • Hot restart capability for quick re-ignition after a brief power interruption.
  • Robust stem construction to enhance durability during transport and handling.
  • Round moly-foil construction for even heat and current distribution, extending lamp iraupena.
  • Dimmable functionality for flexible light output control.

3.2 Fitxa teknikoak

ZehaztapenaBalioa
Modelo zenbakiaAM04730002G
Wat nominalatage1200 W
Bolumen nominalatage100 V
Korronte Nominala12 A
Nominal Luminous Flux110,000 lm
Kolore Tenperatura6,000 K
Kolore errendatze indizea (CRI)Ra 90
Diametroa40.0 mm
Luzera200.0 mm
Bizi-iraupena1,000 h
Oinarri MotaG38
Ezaugarri BereziaErregulagarria

4. Konfigurazioa eta instalazioa

Garrantzitsua: Installation must be performed by a qualified technician in accordance with all local electrical codes and safety regulations. Ensure the power is disconnected before beginning installation.

  1. Prestaketa: Ensure the fixture is compatible with a G38 base HMI lamp and rated for 1200 W. Verify the fixture is clean and free of debris.
  2. L-a maneiatzeaamp: Wear clean, lint-free gloves when handling the lamp. Avoid touching the glass envelope directly, as skin oils can cause damage.
  3. Txertaketa: Carefully align the G38 base pins with the corresponding sockets in the fixture. Insert the lamp firmly but gently until it is fully seated. Do not force the lamp entxufean sartu.
  4. Ziurtatu instalazioa: Close and secure the lamp casing according to the fixture manufacturer's instructions. Ensure all safety interlocks are engaged.
  5. Potentzia-konexioa: Connect the fixture to the appropriate power supply (100 V, 12 A) via a suitable ballast. Ensure all electrical connections are secure.
  6. Hasierako egiaztapena: Before full operation, perform a brief test to ensure the lamp ignites correctly and operates without unusual flickering or noise.

5. Funtzionamendu-argibideak

Behin lamp is correctly installed in a compatible fixture and connected to a suitable ballast, follow these steps for operation:

  1. Piztu: Activate the power supply to the ballast. The lamp should ignite within a few seconds.
  2. Beroketa-aldia: HMI lamps require a short warm-up period (typically 1-5 minutes) to reach full brightness and stable color temperature.
  3. dimming: If your ballast and fixture support dimming, adjust the light output as required. Refer to your ballast's manual for specific dimming procedures.
  4. Hot Restart: Hau lamp supports hot restart. If power is briefly interrupted, the lamp can re-ignite without a significant cooling period. However, frequent hot restarts can reduce lamp bizitza.
  5. Itzali: l itzaltzekoamp, deactivate the power supply to the ballast. Allow the lamp to cool down before any handling.

6. Mantentzea

Regular maintenance ensures optimal performance and extends the lifespan of your OSRAM HMI DIGITAL 1200 W lamp.

  • Garbiketa: Periodically clean the exterior of the lamp and the fixture's reflector/lens with a soft, dry, lint-free cloth. Ensure the lamp is cool and power is disconnected before cleaning. Do not use abrasive cleaners.
  • Ikuskapena: Aldian-aldian ikuskatu lamp for any signs of damage, such as cracks in the glass envelope or discoloration. Check the base for secure connection and signs of wear.
  • Lamp Ordezkoa: Ordeztu lamp when it reaches its rated lifespan (1,000 hours) or if its performance degrades significantly (e.g., reduced brightness, color shift, frequent flickering). Always use genuine OSRAM replacement lamps.
  • Xedapena: Due to mercury content, dispose of spent or broken lamps according to local environmental regulations. Do not dispose of with general household waste.

7. Arazoak

ArazoaKausa posibleaIrtenbidea
Lamp does not ignite.No power to ballast; faulty ballast; incorrect lamp installation; lamp end-of-life.Check power supply; verify ballast operation; re-seat lamp; replace lamp.
Lamp flickers or cycles.Unstable power; ballast issue; lamp nearing end-of-life; improper ventilation.Check power stability; inspect ballast; replace lamp; ensure adequate airflow around fixture.
Reduced brightness or color shift.Lamp nearing end-of-life; dirty reflector/lens; incorrect ballast.Ordeztu lamp; clean fixture optics; verify ballast compatibility.
Lamp breaks during operation.Physical damage; excessive vibration; operating outside specified parameters; faulty fixture.Immediately disconnect power. Follow safety precautions for mercury cleanup. Inspect fixture for damage. Consult qualified technician.

If troubleshooting steps do not resolve the issue, contact OSRAM customer support or a qualified service technician.

8. Bermea eta Laguntza

For information regarding the warranty terms and conditions for your OSRAM HMI DIGITAL 1200 W lamp, please refer to the documentation provided at the time of purchase or visit the official OSRAM website. For technical support, replacement parts, or service inquiries, please contact OSRAM customer service through their official channels.

Informazio gehiago eta harremanetarako datuak aurki ditzakezu hemen: OSRAM denda Amazonen.

© 2023 OSRAM. Eskubide guztiak erreserbatuta. Informazioa alda daiteke abisurik gabe.

Erlazionatutako dokumentuak - AM04730002G

Aurreview Clay Paky SHADOW Projector Instruction Manual - Installation, Operation, and Maintenance
Comprehensive instruction manual for the Clay Paky SHADOW series professional show lighting projectors, including models QS-ST HMI 1200, QS-LT HMI 1200, Basic HMI 1200, and Basic HMI 575. Covers installation, power supply, control signals, channel functions, focusing, maintenance, troubleshooting, and technical data.
Aurreview Aermec HMI Reversible Air/Water Heat Pump Installation Manual
Installation manual for the Aermec HMI reversible air/water heat pump, covering cooling and heating capacities, refrigerant R32, inverter technology, and various system configurations.
Aurreview HMI Metal Halide Lamps Technical Specifications
Technical specifications and safety guidelines for HMI metal halide lamps, including models HMI 300W through HMI 4000W for stage, film, and photography lighting.
Aurreview Funtzio anitzeko magnetiko unibertsala Lamp Argibide eskuliburua
Argibide eta zehaztapen zehatzak Multi-Functional Magnetic Universal L-rakoamp, bere modu desberdinak, muntaketa, erabilera, kargatzea eta segurtasun neurriak estaltzen dituena.
Aurreview OSRAM DECOR STRINGY TABLE 12W CCT WT LED Desk Lamp
Detailed information and specifications for the OSRAM DECOR STRINGY TABLE 12W CCT WT LED desk lamp, including technical data, dimensions, and operational instructions for color temperature and dimming.
Aurreview Abaxis VetScan VS2 Erabiltzailearen Eskuliburua: Konfigurazio, Funtzionamendu eta Mantentze Gida
Abaxis VetScan VS2 Kimika Analizatzailearen gida osoa, albaitaritzako profesionalentzako konfigurazioa, funtzionamendua, probak egiteko prozedurak, konfigurazioa, mantentze-lanak, arazoak konpontzea eta eskaerak egiteko informazioa biltzen duena.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.