Tektronix T912

Tektronix T912 10 MHz-ko biltegiratze osziloskopioaren instrukzio eskuliburua

Eredua: T912

Sarrera

This document serves as the official instruction manual for the Tektronix T912 10 MHz Storage Oscilloscope. It provides comprehensive information regarding the setup, operation, maintenance, and troubleshooting of the instrument. Users are advised to read this manual thoroughly to ensure safe and efficient use of the Tektronix T912 oscilloscope.

Segurtasun Informazioa

Always observe the following safety precautions when operating the Tektronix T912 oscilloscope:

Produktua amaituview: The Instruction Manual

Atal honek gaina ematen duview of the physical instruction manual itself, which guides users through the operation of the Tektronix T912 10 MHz Storage Oscilloscope.

Front cover of the Tektronix T912 10 MHz Storage Oscilloscope Instruction Manual

Figure 1: Front Cover of the Instruction Manual. This image displays the blue front cover of the Tektronix T912 10 MHz Storage Oscilloscope Instruction Manual. The Tektronix logo is prominently featured at the top, with "T912 10 MHz STORAGE OSCILLOSCOPE WITH OPTIONS" and "INSTRUCTION MANUAL" printed below. The manual is spiral-bound on the left side.

Inside cover page of the Tektronix T912 10 MHz Storage Oscilloscope Instruction Manual

Figure 2: Inside Cover Page of the Instruction Manual. This image shows the inside cover page of the manual. It features the Tektronix logo with "COMMITTED TO EXCELLENCE" below it. Text prompts the user to "PLEASE CHECK FOR CHANGE INFORMATION AT THE REAR OF THIS MANUAL." Details about the T912 model, storage oscilloscope, and instruction manual are visible, along with Tektronix Inc. contact information, product group, serial number, and printing dates (First Printing JUL 1975, Revised JUL 1982).

Back cover of the Tektronix T912 10 MHz Storage Oscilloscope Instruction Manual

Figure 3: Back Cover of the Instruction Manual. This image displays the plain blue back cover of the spiral-bound instruction manual. It matches the front cover's color and texture, showing the spiral binding along the left edge.

Konfigurazioa

Proper setup is crucial for accurate measurements and safe operation. Follow these general steps:

  1. Despaketatzea: Carefully remove the oscilloscope and all accessories from its packaging. Inspect for any signs of shipping damage.
  2. Lekua: Place the oscilloscope on a stable, level surface with adequate ventilation space around it.
  3. Potentzia-konexioa: Connect the power cord to the instrument and then to a grounded AC power outlet matching the specified voltage.
  4. Zundaren konexioa: Connect the desired probes to the input channels. Ensure probes are properly compensated before use.
  5. Hasierako piztea: Turn on the oscilloscope and allow it to warm up for a few minutes as per the specific instructions in the full manual.

Funtzionamendu-argibideak

The Tektronix T912 is a 10 MHz storage oscilloscope designed for capturing and displaying waveforms. Basic operation involves:

Mantentzea

Regular maintenance ensures the longevity and performance of your oscilloscope:

Arazoak konpontzea

If you encounter issues with your Tektronix T912, consider the following common troubleshooting steps:

For more detailed troubleshooting, consult the complete instruction manual or contact Tektronix support.

Zehaztapenak

The following specifications apply to the Tektronix T912 10 MHz Storage Oscilloscope:

EzaugarriXehetasuna
FabrikatzaileaTektronix
EreduaT912
Banda zabalera10 MHz
MotaBiltegiratze Oscilloskopioa
Gailu bateragarriakPersonal computer (as per product listing)
Txartel grafikoen interfazeaIntegrated (as per product listing)

Note: Some specifications like "Compatible Devices" and "Graphics Card Interface" are derived from the product listing and may refer to specific configurations or accessories. For detailed technical specifications, refer to the original Tektronix T912 service manual.

Bermea eta Laguntza

For warranty information, please refer to the documentation provided at the time of purchase or contact the seller (ROA) or the manufacturer (Tektronix) directly. Support resources, including technical assistance and service options, can typically be found on the official Tektronix webgunearekin edo haien bezeroarentzako arreta-zerbitzuarekin harremanetan jarriz.

Tektronix, Inc.
500 posta-kutxa
Beaverton, Oregon 97077

First Printing JUL 1975
Revised JUL 1982

Erlazionatutako dokumentuak - T912

Aurreview Tektronix TPP0250 and TPP0500B 10X Passive Probes: Instructions and Specifications
User instructions and technical specifications for Tektronix TPP0250 (250 MHz) and TPP0500B (500 MHz) 10X passive oscilloscope probes, covering setup, operation, accessories, and safety.
Aurreview Tektronix 7 Serieko DPO Errendimendu Osziloskopioa DPO714AX Laguntza Gida
Tektronix 7 Serieko DPO Errendimendu Osziloskopiorako laguntza gida osoa, DPO714AX modeloa. Ikasi proba eta neurketa tresna aurreratu honen ezaugarriei, funtzionamenduari, konfigurazioari eta arazoak konpontzeari buruz.
Aurreview Tektronix 5440 osziloskopioaren instrukzio eskuliburua - Funtzionamendua eta teoria
Tektronix 5440 osziloskopioaren instrukzio-eskuliburu osoa, 5403/D40 seriearen instalazioa, oinarrizko funtzionamendua, ezaugarri aurreratuak eta funtzionamendu-teoria biltzen dituena.
Aurreview Tektronix 4 Series MSO Oscilloscope Specifications and Performance Verification
Comprehensive technical specifications and performance verification procedures for Tektronix 4 Series Mixed Signal Oscilloscopes (MSO), including models MSO44, MSO46, MSO44B, and MSO46B. This document details instrument capabilities and testing methods.
Aurreview Tektronix P5102 100 MHz High-Voltage Zundaren Instrukzio Eskuliburua
Comprehensive instruction manual for the Tektronix P5102 100 MHz High-Voltage Probe, covering safety, operation, adjustment, verification, maintenance, and specifications. Includes detailed guidance for high-voltage neurketak.
Aurreview P6339A 500 MHz Buffered Passive Probe Instruction Manual
Comprehensive instruction manual for the Tektronix P6339A 500 MHz Buffered Passive Probe, detailing its features, operation, specifications, safety precautions, adjustment procedures, and maintenance.