1. Sarrera
The VTSYIQI VTS-160A Water Activity Meter is designed to measure the water activity of various food products. Water activity is a critical factor influencing food stability, microbial growth, and chemical, enzymatic, and physical changes that affect food quality and shelf life. This portable device provides accurate measurements to assist in food preservation and quality control.
Ezaugarri nagusiak:
- Portable and lightweight design (approx. 100g).
- High precision with an accuracy of ±0.02 aw.
- Fast measurement time, typically 5 minutes.
- Integrated sensors and readings for ease of use.
- LCD backlight digital display showing water activity and temperature simultaneously.
- Automatic and manual shutdown functions.
- Azpikontrolatage alarm indication.
- USB data output option for PC connection.

Figure 1.1: The VTS-160A Water Activity Meter in use, demonstrating its application across various food types.

Figure 1.2: Product Introduction diagram highlighting the main components of the VTS-160A meter.
2. Osagaiak eta osagarriak
The VTS-160A Water Activity Meter comes with the following standard accessories:
- Main Unit (VTS-160A Water Activity Meter)
- Sample Plate(s)
- Eramateko zorroa
- Funtzionamendu eskuliburua

Figure 2.1: The VTS-160A Water Activity Meter with its standard accessories, including the carrying case and sample plates.
3. Zehaztapenak
Parametro teknikoak:
| Parametroa | Balioa |
|---|---|
| Bistaratzea | 6-bit backlight LCD digital display (3-bit humidity aw, 3-bit temperature) |
| Barrutia | 0 to 1.0 aw |
| Ebazpena | ±0.01 aw |
| Zehaztasuna | ±0.02 aw |
| Sentsore | Non-conductive humidity sensor |
| Sampling Denbora | 5 minutu (ohikoa) |
| Operating Condition (Temperature) | 0 eta 50 °C artean (32 eta 122 °F) |
| Operating Condition (Humidity) | <95% RH (kondentsatu gabe) |
| Elikatze Hornidura | 2 x 1.5V AAA (UM-4) Batteries (not included) |
| Neurriak | 135 x 70 x 44 mm |
| Pisua | 100g (bateriak gabe) |
Zehaztapen orokorrak:
- Product Dimensions: 40 x 10 x 25 cm (packaged)
- Item Weight: 4 kg (packaged)
- Kolorea: Grisa
4. Konfigurazioa
4.1 Bateriaren instalazioa
- Bilatu bateriaren konpartimentua neurgailuaren atzealdean.
- Irristatu bateriaren estalkia.
- Insert two 1.5V AAA (UM-4) batteries, ensuring correct polarity.
- Itxi bateriaren estalkia ongi.

Figure 4.1: Open battery compartment on the back of the VTS-160A meter.
5. Funtzionamendu-prozedura
5.1 Measuring Water Activity
- Sakatu Boterea key to switch on the meter. The gauge will enter auto mode, automatically initiating the water activity test.
- Jarri zure sample s garbi batean sartuample plate. Ensure the sample is representative and fills the plate adequately without overflowing.
- Carefully cover the sensor of the meter onto the sample plate, ensuring a good seal.
- Allow approximately 5 minutes for the reading to stabilize. Once stable, the water activity value will be displayed on the LCD.
- After testing, press and hold the Boterea key for approximately 3 seconds to turn off the meter.
- Garbitu sample plate thoroughly after each use to prevent cross-contamination and ensure accurate future readings.

Figure 5.1: Step-by-step guide for performing a water activity measurement.
6. Reading Correction (Calibration)
If it becomes necessary to correct the reading value, follow these steps:
- Eduki sakatuta Boterea tekla gutxi gorabehera 7 segundoz.
- Release the key when the signal 'Cor' appears on the display. A decimal number with two places, representing the current correction value, will be shown.
- Open the battery cover on the back of the meter. Below the battery slot, you will find two small holes.
- Using a small, hard, non-conductive tool (e.g., a small screwdriver or toothpick), gently touch the key inside the left hole to increase the correction value.
- Gently touch the key inside the right hole to decrease the correction value. Adjust the value as needed.
- Sakatu Boterea key again to confirm the new correction value. The measured reading will update, and the calibration is complete.

Figure 6.1: Step-by-step guide for performing reading correction.
7. Mantentzea
7.1 Garbiketa
- Garbitu beti sample plate immediately after each use to prevent residue buildup, which can affect measurement accuracy.
- Erabili biguna, damp cloth to wipe the exterior of the meter. Do not use abrasive cleaners or solvents.
- Ensure no liquids enter the sensor area or battery compartment.
7.2 Biltegiratzea
- When not in use, store the meter in its carrying case to protect it from dust and physical damage.
- Gorde leku fresko eta lehor batean, eguzki-argitik eta muturreko tenperaturatik urrun.
- Kendu bateriak gailua denbora luzez erabiliko ez bada, isuriak saihesteko.
8. Arazoak
If you encounter issues with your VTS-160A Water Activity Meter, consider the following:
- Potentziarik gabe: Egiaztatu bateriak behar bezala instalatuta dauden eta nahikoa karga duten. Beharrezkoa bada, ordezkatu bateriak.
- Irakurketa okerrak: Ziurtatu sample plate is clean and the sensor is properly seated on the sample. Perform a reading correction as described in Section 6. Verify that the operating conditions (temperature, humidity) are within the specified range.
- Slow Readings: Ziurtatu sample is properly prepared and the environment is stable.
- Bistaratzeko arazoak: Pantaila ilun edo keinuka badago, ordezkatu bateriak.
Urrats hauekin konpontzen ez diren arazo iraunkorrak badituzu, jarri harremanetan bezeroarentzako arreta-zerbitzuarekin.
9. Laguntza-informazioa
For technical assistance, warranty inquiries, or service, please contact VTSYIQI customer support through your purchase platform or the official VTSYIQI webgunea.
Please have your model number (VTS-160A) and purchase date available when contacting support.