Jectse Jectseh4tnewb30y-03
Jectse Timer Soft Starter Instruction Manual
Model: Jectseh4tnewb30y-03
1. Produktua amaitu daview
The Jectse Timer Soft Starter is a versatile delay relay motor starter designed for efficient motor start control. It features adjustable delay ranges and wide working voltage compatibility, making it suitable for various industrial and scientific applications.

1. irudia: Aurrealdea view of the Jectse Timer Soft Starter, showing the control knobs and indicator lights.
2. Ezaugarri nagusiak
- Adjustable Start Delay (T1): Range from 0.1 seconds to 10 minutes, set via knob.
- Adjustable Conversion Time (T2): Range from 0.1 seconds to 1 second, set via knob.
- Lan-bolumen zabalatage: Supports AC/DC 12V to 240V.
- LED adierazleak: Clearly shows the working status of the relay.
- Diseinu trinkoa: Super small size, only 18mm wide, designed for 35mm rail mounting.

Figure 2: The soft starter unit highlighting its compact size and adjustable settings.
3. Segurtasun informazioa
Please read and understand all safety instructions before installing or operating this device. Failure to follow these instructions may result in electrical shock, fire, or serious injury.
- Ziurtatu korrontea deskonektatuta dagoela edozein instalazio edo kableatu egin aurretik.
- Instalazioa langile kualifikatuek bakarrik egin behar dute.
- Egiaztatu liburu zuzenatage and current ratings before connecting to a power source.
- Ez jarri gailua hezetasun edo muturreko tenperaturetara.
- Ziurtatu lurreratze egokia behar den lekuan.
4. Paketearen edukia
Paketeak barne hartzen ditu:
- 1 x Jectse Timer Soft Starter
5. Konfigurazioa eta instalazioa
The Jectse Timer Soft Starter is designed for 35mm DIN rail mounting. Follow these steps for proper installation:
- Ensure all power to the circuit is turned off at the main breaker.
- Mount the soft starter securely onto a standard 35mm DIN rail. The red clips on the side facilitate easy mounting and removal.
- Connect the power supply to terminals A1 and A2. The device supports AC/DC 12-240V.
- Connect the motor control wiring to the output terminals (15, 16, 18, 25, 26, 28) as per your application's wiring diagram. Refer to the diagram on the side of the unit for specific connections.
- Ensure all wiring connections are secure and meet the specified wiring capacity (1x2.5mm² or 2x 1.5mm²).
- Egiaztatu konexio guztiak elikadura berrezarri aurretik.

3. irudia: hurbileko planoa view of the wiring terminals and the integrated wiring diagram on the unit.

4. irudia: Aldea view illustrating the red clips for DIN rail mounting.
6. Funtzionamendu-argibideak
Once installed and powered, the Timer Soft Starter operates based on its configured delay settings.
- Setting Start Delay (T1): Use the knob labeled 'T1' to adjust the initial start delay from 0.1 seconds to 10 minutes. This delay determines how long the soft starter waits before initiating the motor start sequence.
- Setting Conversion Time (T2): Use the knob labeled 'T2' to set the conversion time from 0.1 seconds to 1 second. This time is crucial for the smooth transition during the motor's soft start phase.
- LED adierazleak:
- A green LED indicates the power status (Un).
- A red LED indicates the relay's working status (R).
1. bideoa: Over batview of the Jectse Timer Soft Starter, demonstrating its features and appearance.
7. Mantentzea
The Jectse Timer Soft Starter is designed for long-term reliability with minimal maintenance. However, regular checks can ensure optimal performance:
- Aldian-aldian egiaztatu kableatu-konexioak estutasuna eta higadura edo korrosio zantzurik dagoen egiaztatzeko.
- Mantendu unitatea garbi eta hautsik eta hondakinik gabe. Erabili zapi lehor eta leun bat garbitzeko.
- Ziurtatu funtzionamendu-ingurunea zehaztutako tenperatura eta hezetasun tarteen barruan mantentzen dela.
- Do not attempt to open or repair the unit yourself. Refer to qualified service personnel.
8. Arazoak
If you encounter issues with your Timer Soft Starter, consider the following common problems and solutions:
| Arazoa | Kausa posiblea | Irtenbidea |
|---|---|---|
| Unit not powering on (Green LED off) | No power supply; Incorrect wiring; Faulty unit. | Check power source; Verify A1/A2 wiring; Contact support if power is present and wired correctly. |
| Motor not starting after delay | Incorrect output wiring; Relay not activating; Motor issue. | Check output terminals (15, 16, 18, 25, 26, 28) connections; Observe red LED for relay status; Test motor independently. |
| Delay times are inaccurate | Knob settings incorrect; Environmental factors. | Re-adjust T1 and T2 knobs carefully; Ensure stable operating environment. |
If the problem persists after attempting these solutions, please contact Jectse customer support.
9. Zehaztapenak
| Parametroa | Balioa |
|---|---|
| Mota | AC/DC 12V~240V |
| Rated Control Power Supply Voltage | AC/DC 12-240V (50/60Hz) |
| Energia-kontsumoa | AC 0.7-3VA / DC 0.5-1.7W |
| Starting Delay (T1) | 0.1s - 10min |
| Conversion Delay (T2) | 0.1s - 1s |
| Ezarpenaren zehaztasuna | 5% |
| Errepikatu zehaztasuna | %0.2 |
| Irteera | Two sets of conversion contacts 16A/AC250VAC |
| Minimum Switching Power | 500mW |
| Bizitza Mekanikoa | 1 x 10,000,000 cycles |
| Electrical Life (Load) | 1,000,000 ziklo |
| Berrezarri ordua | 200 ms gehienez |
| Lan-ingurunearen tenperatura | -20°C ~ 55°C |
| Biltegiratze eta Garraio Tenperatura | -35°C ~ 75°C |
| Instalazioa | 35 mm-ko errailaren muntaketa |
| Babes Maila | IP20 |
| Instalazioaren altuera | 2000 metro |
| Kutsadura Maila | 2 |
| Kableatu ahalmena | 1x2.5mm² or 2x 1.5mm² |
| Neurriak | 90 x 18 x 64 mm (3.5 x 0.7 x 2.5 in) |
| Arauari egokituta | GB14048.5.IEC/EN 60255-1 |
| Pisua | Gutxi gorabehera. 96g (3.4 oz) |
10. Bermea eta Laguntza
For warranty information or technical support, please contact Jectse customer service. Keep your purchase receipt for any warranty claims.
Fabrikatzailea: Jetse
Modelo zenbakia: Jectseh4tnewb30y-03
Lehen eskuragarri dagoen data: 4ko maiatzaren 2019a
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.