1. Produktua amaitu daview
The Jectse 2-in-1 Chlorine PH Meter is an essential tool designed for quick and accurate measurement of pH and chlorine (Cl2) levels in swimming pools and spas. This portable device ensures your water remains within safe and ideal ranges for optimal enjoyment and health.
Ezaugarri nagusiak:
- Essential Tool: Provides quick and accurate pH and chlorine (Cl2) level measurements.
- Erabiltzeko erraza: Features a large screen display for clear and accurate readings, simplifying operation.
- Eraikuntza iraunkorra: Made of high-quality plastic materials, ensuring wear resistance, waterproofing, and long service life.
- Diseinu eramangarria: Compact and lightweight for convenient handling and storage.
2. Segurtasun informazioa
- Mantendu gailua eguzki-argitik eta muturreko tenperaturatik urrun.
- Do not immerse the main body of the meter in water. Only the probe is designed for water contact.
- Gorde gailua leku lehor eta fresko batean erabiltzen ez duzunean.
- Mantendu haurren eskura.
- Ensure proper battery disposal according to local regulations.
3. Paketearen edukia
Egiaztatu elementu guztiak paketean daudela:
- 1 x CL2 Chlorine & PH Analysis Meter (Main Body)
- 1 x Probe with Cable
4. Produktuaren osagaiak

4.1. irudia: Main unit and probe assembly. The main unit features a large display for readings, and the probe connects via a coiled cable.

4.2. irudia: Xehetasuna view of the meter's features, including the convenient probe slot for storage, the flexible telescopic extension cord, and the battery compartment for power.
- Gorputz nagusia: Houses the display, control buttons, and battery compartment. Dimensions: 190 x 120mm / 7.5 x 4.7in.
- Zunda: The sensing element that is immersed in water. Probe Length: 48mm / 1.9in (excluding black belt). Handle probe length: 150mm / 5.9in.
- Kablea: Connects the probe to the main body. Cable Length: 130mm / 5.1in.
5. Konfigurazioa
5.1 Bateriaren instalazioa
- Kokatu bateriaren konpartimendua unitate nagusiaren atzealdean.
- Ireki bateriaren estalkia.
- Insert one (1) AA 1.5V alkaline battery, ensuring correct polarity (+/-). (Bateria ez dago barne)
- Itxi bateriaren estalkia ongi.
5.2 Hasierako Prestaketa
- Connect the probe cable to the designated port on the main unit.
- Ensure the probe is clean and dry before first use.
6. Funtzionamendu-argibideak
6.1 Measuring pH and Chlorine Levels

6.1. irudia: Proper technique for immersing the probe in pool water for accurate readings.

6.2. irudia: The chlorine level scale on the meter, indicating ideal and caution ranges. The recommended chlorine content for swimming pools and hot springs is 1.2~1.7ppm.

6.3. irudia: The pH level scale on the meter, showing acid, ideal, and alkaline ranges. The recommended pH for swimming pools and spas is 7.2-7.8.
- Before testing, ensure the water sample is still and free of debris.
- Press the 'PH/CL2' button to turn on the meter.
- Immerse the probe into the water sample, ensuring both metal electrodes are fully submerged.
- Wait for the reading to stabilize on the large display.
- Read the pH and chlorine (CL2) levels directly from the meter's scale.
- Compare the readings with the ideal ranges indicated on the meter's display (e.g., for chlorine: 1.2-1.7ppm; for pH: 7.2-7.8).
- After use, remove the probe from the water and wipe it clean and dry.
- Press the 'PH/CL2' button again to turn off the meter.
6.2 Kalibrazioa
Accurate calibration is crucial for reliable readings. Please follow these steps carefully:
- You need to prepare a 1.5 PPM (parts per million) chlorine solution in the pool water for initial calibration. This serves as your reference point.
- If you are unsure if the chlorine content is exactly 1.5 PPM, or if you cannot easily create a precise calibration point, it is recommended to use a traditional test strip or a professionally verified water sample to confirm the 1.5 PPM chlorine level.
- Once the pool water has been calibrated with the 1.5 PPM chlorine solution, there is generally no need to recalibrate unless you change to measure a different pool's water or if you suspect the meter's accuracy has drifted.
7. Mantentzea
7.1 Garbiketa
- After each use, gently wipe the probe electrodes with a soft, clean cloth to remove any water residue or contaminants.
- Do not use abrasive cleaners or solvents on the meter or probe.
- Keep the main body dry. If it gets wet, wipe it immediately with a dry cloth.
7.2 Biltegiratzea
- Store the meter and probe in a cool, dry place, away from direct sunlight and extreme temperatures.
- If storing for an extended period, remove the battery to prevent leakage and damage to the device.
- Utilize the probe slot on the main unit for secure storage of the probe when not in use.
8. Arazoak
| Arazoa | Kausa posiblea | Irtenbidea |
|---|---|---|
| Neurgailua ez da pizten. | Bateria hilda edo gaizki instalatuta. | Replace the AA 1.5V battery, ensuring correct polarity. |
| Irakurketa zehaztugabeak edo koherenteak ez direnak. |
|
|
| Pantaila ilun dago edo keinuka ari da. | Bateria baxua. | Replace the AA 1.5V battery. |
9. Zehaztapenak
| Zehaztapena | Balioa |
|---|---|
| Gorputzaren Tamaina Nagusia | 190 x 120mm / 7.5 x 4.7in |
| Handle Probe Length | 150 mm / 5.9in |
| Probe Length (excluding black belt) | 48 mm / 1.9in |
| Kablearen luzera | 130 mm / 5.1in |
| Elikatze Hornidura | 1 x AA 1.5V alkaline battery (NOT included) |
| Materiala | Plastikoa |
| Elementuaren pisua | 10.6 ontza |
| Produktuaren neurriak | 7.48 x 4.72 x 1.97 hazbete |
10. Bermea eta Laguntza
Jectse is committed to providing quality products and customer satisfaction. While specific warranty details are not provided in this manual, if you encounter any issues or have questions regarding your Jectse 2-in-1 Chlorine PH Meter, please contact Jectse customer support through the retailer's platform or the official Jectse website. Our team will endeavor to provide a complete solution within 24 hours.
Informazio gehiagorako, bisitatu Jectse Store on Amazon.