1. Produktua amaitu daview
The Jectse AR925 Digital Contact Tachometer is an instrument designed for precise measurement of rotating and linear rolling speeds. It utilizes advanced electro-optical technology to provide accurate readings across a wide range of applications. This device is equipped with a clear LCD display and features automatic storage of maximum, minimum, and last measured values for convenient data analysis.

Image 1.1: Jectse AR925 Digital Contact Tachometer in use, showing the display.
Ezaugarri nagusiak:
- Utilizes MCU and electro-optical technology for efficient measurement of rotating and linear rolling speed.
- Wide measuring range of 0.5-19999 RPM with high resolution.
- Large LCD display for clear and easy-to-read measurements.
- Automatically stores the maximum (MAX), minimum (MIN), and last (LAST) measured values.
- Includes convertible accessories for various measurement applications.
2. Paketearen edukia
Despaketatzean, egiaztatu behean zerrendatutako elementu guztiak daudela eta egoera onean daudela:
- 1 x Jectse AR925 Digital Contact Tachometer
- 1 x Linear Circular Probe
- 1 x Speed Column Probe
- 1 x Speed Large Cone Probe
- 1 x Speed Small Cone Probe
- 1 x garraiatzeko poltsa
- 1 x Erabiltzailearen eskuliburua (dokumentu hau)

Image 2.1: The tachometer and its various contact probes and carrying bag.
3. Gailuaren osagaiak
Familiarize yourself with the main components and controls of the AR925 Digital Contact Tachometer:

Image 3.1: Labeled diagram of the tachometer's front panel and contact head.
- Contact Rotate Head: The rotating shaft where different contact probes are attached for measurement.
- LCD pantaila: Shows measurement readings, units, and stored values.
- Memory Button (MEM): Used to access stored MAX, MIN, and LAST values.
- Measure MAX/MIN Value Button: Toggles between displaying maximum and minimum recorded speeds.
- Switch/Null Button (ON/NULL): Powers the device on/off and can be used to clear readings or reset.
- Unit Button (UNIT): Changes the measurement unit (e.g., RPM, m/min, ft/min).
4. Zehaztapenak
The following table outlines the technical specifications of the Jectse AR925 Digital Contact Tachometer:

Image 4.1: Visual representation of the tachometer's dimensions and key parameters.
| Parametroa | Balioa |
|---|---|
| Neurketa-eremua | 0.5-19999 RPM, 0.05-19999.9 m/min, 0.2-6560 Ft/min |
| Ebazpen ratioa | 0.1 RPM, 1 RPM, 0.01 m/min, 0.1 m/min, 1 Ft/min |
| Measure Error | ±(0.05%+1 digit) |
| Sampling maiztasuna | 0.8 seg |
| Measure Method | Harremanetan jarri |
| Laneko Tenperatura | 0~50°C |
| Biltegiratze Tenperatura | -20~70°C |
| Boterea | 3 * 1.5V AAA battery (Not included) |
| Pisua | 132 g |
| Neurriak (L x W x H) | 155 mm x 55 mm x 35 mm (6.1 x 2.2 x 1.4 hazbete) |
| Materiala | Akrilonitrilo Butadieno Estirenoa (ABS) |
5. Bateriaren instalazioa
The AR925 Digital Contact Tachometer requires three (3) AAA batteries (not included) for operation. Follow these steps to install the batteries:
- Locate the battery compartment cover on the back of the tachometer.
- Irristatu bateriaren konpartimentuaren estalkia behera edo kanpora irekitzeko.
- Insert three (3) AAA batteries, ensuring correct polarity (+ and -) as indicated inside the compartment.
- Jarri bateriaren konpartimentuaren estalkia berriro bere lekuan sartuz, ondo klik egin arte.

5.1. irudia: View of the open battery compartment, showing where to insert AAA batteries.
6. Funtzionamendua
This section details how to use your Jectse AR925 Digital Contact Tachometer for various measurements.
6.1 Piztu/Itzaltzea
- Gailua pizteko, sakatu ON/NULL botoia.
- The device will automatically power off after approximately 30 seconds of inactivity to conserve battery life. There is no dedicated 'off' button.
6.2 Attaching Contact Probes
Select the appropriate contact head (Linear Circular, Speed Column, Speed Large Cone, or Speed Small Cone) based on the object to be measured. Gently push and twist the chosen probe onto the Contact Rotate Head until it is securely attached.

6.1. irudia: Amaituview of the multi-sensor probes included with the tachometer.
6.3 Neurketak hartzea
- Ensure the correct contact probe is attached.
- Sakatu ON/NULL button to power on the tachometer.
- Gently press the rotating part of the contact probe against the center of the rotating shaft or surface of the object you wish to measure. Maintain steady contact.
- The LCD display will show the real-time measurement.
- To change the measurement unit (RPM, m/min, ft/min), press the UNITATEA botoia.

Image 6.2: Step-by-step illustration of the contact measurement method.
6.4 Viewing Stored Values (MAX/MIN/LAST)
The tachometer automatically stores the maximum, minimum, and last measured values. To view these:
- Neurketa egin ondoren, sakatu botoia MEM botoia.
- Sakatu bakoitzak MEM button will cycle through the MAX, MIN, and LAST recorded values.
- The display will indicate which value is currently shown (e.g., "MAX", "MIN", "LAST").
Video 6.3: A demonstration of the Jectse Digital Contact Tachometer in operation, showcasing its features and measurement capabilities.
7. Mantentzea
Proper maintenance ensures the longevity and accuracy of your tachometer.
- Garbiketa: Garbitu gailua zapi leun eta lehor batekin. Ez erabili garbitzaile edo disolbatzaile urratzailerik.
- Biltegiratzea: When not in use for extended periods, remove the batteries to prevent leakage. Store the tachometer and its accessories in the provided carrying bag in a cool, dry place, away from direct sunlight and extreme temperatures.
- Zunda zaintzea: Inspect contact probes regularly for wear or damage. Replace if necessary to maintain measurement accuracy. Avoid exposing rubber tips to high temperatures, as they may melt.
8. Arazoak
If you encounter issues with your tachometer, refer to the following common problems and solutions:
| Arazoa | Kausa posiblea | Irtenbidea |
|---|---|---|
| Gailua ez da pizten. | Bateriak hilda edo gaizki instalatuta. | Egiaztatu bateriaren polaritatea. Ordeztu AAA bateria berriekin. |
| Irakurketa zehaztugabeak edo koherenteak ez direnak. | Loose contact with the rotating object; damaged probe; low battery. | Ensure firm and stable contact. Inspect and replace the probe if damaged. Replace batteries. |
| Display shows '0' or no change during measurement. | No contact or insufficient rotation. | Verify the object is rotating. Ensure the probe is making proper contact with the rotating surface. |
| Rubber tips on probes melt or deform. | Tenperatura altuen esposizioa. | Avoid using the tachometer on surfaces exceeding the probe's temperature resistance. Consider alternative measurement methods for high-temperature applications. |
9. Bermea eta Laguntza