WENGART WG02

Wengart WG02 Thermal Actuator AC 230V Instruction Manual

Eredua: WG02

1. Produktua amaitu daview

The Wengart WG02 Thermal Actuator is designed for use with manifold bypass valves and small dynamic balancing valves in underfloor heating systems. It controls the electrical component of the valve, regulating temperature through the thermal expansion and contraction of a temperature-sensing element. This design ensures quiet operation, compact size, and low power consumption, contributing to energy efficiency.

Wengart WG02 Thermal Actuator with key features listed

Image 1: Wengart WG02 Thermal Actuator highlighting features such as thermostatic control, energy saving, stable operation, silent operation, flame retardant PC material, and easy installation.

Ezaugarri nagusiak:

  • Kontrol termostatikoa: Utilizes thermal expansion for precise temperature regulation.
  • Energia aurreztea: Efficient design with low power consumption.
  • Eragiketa egonkorra: Reliable performance without mechanical wear.
  • Funtzionamendu isila: Operates without noise.
  • Material iraunkorra: Constructed from flame-retardant PC material.
  • Instalazio erraza: Features a nut connection for quick setup.
  • LED adierazlea: Small black dot indicates the actuator's on/off status.
  • Spring Return Function: Valve closes automatically upon power failure.
Wengart WG02 Thermal Actuator installed in an underfloor heating manifold system

Image 2: The Wengart WG02 Thermal Actuator shown in an application context, integrated into an underfloor heating manifold system.

2. Zehaztapenak

ZehaztapenaBalioa
Modelo zenbakiaWG02
liburukiatage230 V AC
Energia egonkorra2 W
Giro-tenperatura-5 eta 50 ℃ artean
Hari Mota2 x 0.5 mm² (Normally Closed)
Hari-konexioaM30 x 1.5 mm
Trazuaren Luzera3 - 4 mm
Full Open/Close Time180 - 300 seconds (approx. 3-5 minutes)
Kablearen luzera800 mm
Babes KlaseaIP54
Neurriak (L x W x H)38 x 38 x 58 mm (1.5 x 1.5 x 2.3 hazbete)
MaterialaPlastikoa
Diagram showing the dimensions of the Wengart WG02 Thermal Actuator

Image 3: Detailed dimensions of the Wengart WG02 Thermal Actuator, including its length, width, height, and cable length, with the M30x1.5mm thread interface highlighted.

3. Konfigurazioa eta instalazioa

The Wengart WG02 Thermal Actuator is designed for straightforward installation using a nut connection method. Ensure the valve you are connecting to has an M30 x 1.5 mm thread for compatibility.

3.1 Kableatzeko jarraibideak

Connect the actuator to your thermostat and power supply as per the diagram below. The actuator requires an AC 230V power source. For optimal control, integrate with a compatible thermostat (e.g., WG-806).

Wiring diagram for Wengart WG02 Thermal Actuator with WG-806 thermostat

Image 4: Wiring diagram illustrating the connection of the Wengart WG02 Thermal Actuator to an AC 230V power supply and a WG-806 thermostat, including an optional external sensor.

Kableatu konexioak:

  • Connect the L (Live) and N (Neutral) wires from your AC 230V supply to the corresponding terminals on the thermostat.
  • Connect the L1 and N1 terminals from the thermostat to the actuator's power input.
  • If using an external sensor, connect it to the designated terminals on the thermostat.

3.2 Aktuadorea muntatzea

The actuator connects directly to the valve body using its M30 x 1.5 mm nut connection. Ensure a secure fit to prevent leaks and ensure proper operation.

Installation steps for Wengart WG02 Thermal Actuator on a manifold

Image 5: Step-by-step installation guide for the Wengart WG02 Thermal Actuator, showing connection to a thermostat and mounting onto a heating manifold. Note the stroke length of 3-4 mm and the 3-5 minute activation time.

  1. Ensure the heating system is depressurized and cooled before installation.
  2. Thread the actuator onto the M30 x 1.5 mm valve connection. Hand-tighten first, then use a wrench if necessary to ensure a snug fit without overtightening.
  3. Connect the electrical wires as shown in the wiring diagram (Image 4).
  4. Once powered on, the actuator will take approximately 3-5 minutes to fully open or close, achieving a stroke length of 3-4 mm.
Xehetasuna view of Wengart WG02 components: paraffin element, nut connection, and LED indicator

Image 6: Detailed breakdown of the Wengart WG02 Thermal Actuator, illustrating its excellent paraffin-driven element, simple nut connection for easy disassembly, and the LED indicator light.

4. Funtzionamendu-argibideak

The Wengart WG02 Thermal Actuator operates in conjunction with a thermostat to regulate the flow of heating fluid. It functions based on the thermal expansion and contraction of a paraffin element, driven by PTC heating.

4.1 Actuator Status Indication

The actuator features a 360-degree LED indicator (a small black dot) that illuminates when the actuator is powered and actively opening the valve. When the LED is off, the actuator is not powered, and the valve is closed (normally closed operation).

Diagram showing actuator status (open/closed) based on thermostat heating and LED indicator

Image 7: Illustration of the actuator's operational status. When the thermostat is heating, the electrothermal actuator opens, and the 360° LED indicator is on. When the thermostat is not heating, the actuator closes, and the LED indicator is off.

4.2 Thermostat Integration

When used with a compatible thermostat, the actuator enables separate room control, reducing energy consumption. The valve will close when the room temperature reaches the set temperature on the thermostat, and open when heating is required.

4.3 Power Failure Safety

The actuator is designed with a spring return function, meaning the valve will automatically close in the event of a power failure. This ensures a failsafe operation, preventing uncontrolled heating.

5. Mantentzea

The Wengart WG02 Thermal Actuator is designed for long-term, maintenance-free operation due to its non-mechanical transmission and durable components. No regular lubrication or component replacement is typically required.

Gomendatutako egiaztapenak:

  • Periodically inspect the actuator and wiring for any visible damage or loose connections.
  • Ensure the LED indicator functions correctly when the thermostat calls for heat.
  • Keep the actuator free from dust and debris to maintain optimal performance.

6. Arazoak

If you encounter issues with your Wengart WG02 Thermal Actuator, refer to the following troubleshooting steps:

  • Actuator not opening/closing:
    • Check if the thermostat is calling for heat (for opening) or not (for closing).
    • Verify that the actuator is receiving AC 230V power.
    • Egiaztatu kableatu-konexio guztiak solteak edo kalteak dauden.
    • Ensure the actuator is securely threaded onto the valve.
  • LED adierazlea ez da pizten:
    • Confirm the actuator is powered and the thermostat is actively calling for heat.
    • Check the power supply to the actuator.
  • Valve not fully opening or closing:
    • Allow the full 3-5 minutes for the actuator to complete its stroke.
    • Ensure there are no obstructions preventing the valve from moving freely.

If problems persist after performing these checks, consult a qualified technician.

7. Bermea eta Laguntza

Specific warranty details for the Wengart WG02 Thermal Actuator are not provided in this manual. Please refer to your purchase documentation or contact the retailer/manufacturer directly for warranty information and technical support.

© 2026 WENGART. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.