The Gima Vega Uno Surgical Aspirator is a compact and reliable medical device designed for the aspiration of liquids such as mucus, phlegm, and blood from nasal, oral, or tracheal passages in both adults and children. This device is suitable for minor surgical procedures and post-operative home care. It features instant suction intensity adjustment and a robust design for professional use.

Gima Vega Uno Aspirator recommended for nasal, oral, or tracheal fluid aspiration in adults or children.

Image 1.1: The Gima Vega Uno Aspirator is recommended for nasal, oral, or tracheal fluid aspiration in adults or children.

2. Segurtasun informazioa

Please read all instructions carefully before using the Gima Vega Uno Surgical Aspirator. Failure to follow safety guidelines may result in injury or damage to the device.

  • Ensure the device is placed on a stable, flat surface during operation.
  • Ez sartu unitate nagusia uretan edo beste likido batean.
  • Mantendu gailua bero-iturrietatik eta eguzki-argitik urrun.
  • Only use accessories and replacement parts approved by GIMA.
  • Regularly inspect all components for damage or wear before each use.
  • The electrical and thermal parts of the aspirator are insulated for safety. Do not attempt to open or repair the main unit. Refer servicing to qualified personnel.
  • Deskonektatu beti energia-iturria garbiketa edo mantentze-lanak egin aurretik.
  • This device is intended for medical use. Consult a healthcare professional for proper usage techniques and medical advice.
Insulated and safe electrical parts of the Gima Vega Uno Aspirator.

Image 2.1: The Gima Vega Uno features insulated and safe electrical parts.

3. Produktua amaitu daview

3.1 Osagaiak

The Gima Vega Uno Surgical Aspirator typically includes the following components:

  • Aspirator main unit
  • Collection container (Makrolon, 1L or 2L)
  • Suction tubes (silicone, autoclavable)
  • Bota eta botatzeko iragazkia
  • Conical connector for catheters
  • Argibide eskuliburua
Diagram showing the components of the Gima Vega Uno Surgical Aspirator, including the main unit, collection container, tubes, and controls.

Image 3.1: Diagram of the Gima Vega Uno components and controls.

3.2 Ezaugarri nagusiak

  • Silent and High-Flow Pumps: Designed for quiet operation and efficient fluid aspiration.
  • Maintenance-Free Pumps: Ensures long-lasting performance without frequent servicing.
  • Instant Suction Intensity Adjustment: Allows precise control over aspiration strength.
  • Unbreakable Makrolon Container: Durable collection container available in 1L or 2L capacity.
  • Autoclavable Components: The collection container and silicone tubes can be sterilized at 121°C.
  • Liquid Level Control Valve: Prevents overflow into the main unit.
  • Hydrophobic, Antibacterial, Anti-reflux Filter: Provides enhanced hygiene and protection.
  • Diseinu trinkoa: Kudeatzeko eta gordetzeko erraza.
Illustration of the Gima Vega Uno's silent, high-flow, and maintenance-free pumps.

Image 3.2: The aspirator features silent, high-flow, and maintenance-free pumps.

Diagram illustrating the hydrophobic, antibacterial, and anti-reflux filter of the Gima Vega Uno.

Image 3.3: The filter is hydrophobic, antibacterial, and anti-reflux.

4. Konfiguratzeko argibideak

  1. Desegin: Kontu handiz atera osagai guztiak paketetik. Begiratu ea kalterik dagoen.
  2. Assemble Collection Container: Ensure the lid of the collection container is securely fastened.
  3. Connect Suction Tubes: Attach one end of the silicone suction tube to the 'PATIENT' port on the collection container lid. Connect the other end to the conical connector for the catheter.
  4. Connect Aspirator to Container: Connect the 'VACUUM' port on the collection container lid to the suction inlet on the main aspirator unit. Ensure all connections are tight to prevent air leaks.
  5. Txertatu iragazkia: Place the disposable filter between the collection container and the main unit, ensuring it is correctly oriented as per the markings.
  6. Potentzia-konexioa: Plug the power cord into a suitable electrical outlet (230 Volt).
Gima Vega Uno Surgical Aspirator fully assembled with collection container and tubing.

Image 4.1: The Gima Vega Uno Aspirator ready for use.

5. Funtzionamendu-argibideak

  1. Piztu: Press the ON/OFF switch to turn on the aspirator. The indicator light will illuminate.
  2. Xurgapen intentsitatea doitzea: Use the regulation knob to adjust the desired suction intensity. Monitor the vacuum gauge (kPa/Bar) for the current suction level.
  3. Aspirazioa egin: Carefully insert the catheter connected to the suction tube into the patient's nasal, oral, or tracheal passage as instructed by a healthcare professional.
  4. Monitor Collection Container: Observe the liquid level in the collection container. The integrated valve prevents overflow. Do not allow the container to overfill.
  5. Itzali: Once aspiration is complete, press the ON/OFF switch to turn off the device.
  6. Deskonektatu: Deskonektatu korronte-kablea entxufetik.

6. Mantentzea eta Garbiketa

Proper maintenance and cleaning are crucial for the longevity and hygienic operation of your Gima Vega Uno Aspirator.

  • Eguneko garbiketa: After each use, empty and clean the collection container. The Makrolon container and silicone tubes are autoclavable at 121°C. Wash them with warm water and a mild detergent, then rinse thoroughly.
  • Esterilizazioa: For sterilization, place the cleaned container and tubes in an autoclave at 121°C according to standard sterilization protocols.
  • Iragazkiaren ordezkoa: The disposable filter should be replaced regularly, or immediately if it becomes wet or visibly soiled. Do not attempt to clean and reuse the filter.
  • Hodien ikuskapena: Regularly inspect silicone tubes for any signs of wear, cracks, or blockages. If mold or persistent residue is observed inside the tubes, they should be thoroughly cleaned or replaced.
  • Kanpoko garbiketa: Garbitu unitate nagusiaren kanpoaldea oihal leun eta lehor batekinamp oihalik. Ez erabili garbitzaile urratzailerik eta ez murgildu unitatea uretan.
Image showing self-cleaning vessels, indicating ease of maintenance for the Gima Vega Uno.

Image 6.1: The aspirator features self-cleaning vessels for easy maintenance.

7. Arazoak

If you encounter issues with your Gima Vega Uno Aspirator, refer to the following common problems and solutions:

ArazoaKausa posibleaIrtenbidea
Xurgapen ez edo xurgapen ahula
  • Loose connections in tubing
  • Clogged catheter or tubing
  • Full collection container
  • Damaged filter
  • Improperly sealed container lid
  • Jantzitako zigiluak
  • Check and tighten all tube connections.
  • Clear or replace the catheter/tubing.
  • Hustu bilketa-ontzia.
  • Replace the disposable filter.
  • Ensure the container lid is securely closed.
  • Inspect and replace any worn seals (e.g., on the container lid). Applying a light silicone paste to seals can improve performance.
Gailua ez da pizten
  • Ez dago elikadura hornidurarik
  • Elikatze-kable akastuna
  • Egiaztatu elikatze-kablea ondo konektatuta dagoen entxufe funtzional batera.
  • Probatu entxufea beste gailu batekin.
  • If the power cord is damaged, contact customer support for a replacement.
Ezohiko zarata funtzionamenduan
  • Barne osagaien arazoa
  • Pieza solteak
  • Itzali gailua berehala.
  • Contact customer support for assistance. Do not attempt to open the unit.

8. Zehaztapenak

ZehaztapenaXehetasuna
FabrikatzaileaCA-MI SRL
Modelo zenbakia28209
Elementuaren pisua2.2 kilogramo
Produktuaren neurriak25 x 19 x 16.5 cm
Volume of Item1 Litre (container)
liburukiatage230 Volt
Ezaugarri bereziakTrinkoa
Dakarten osagaiakAspirator, manual
Beharrezko bateriakEz

9. Bermea eta Laguntza