Leviton DT130-1LW

Leviton DT130-1LW Countdown Timer Switch User Manual

Model: DT130-1LW

1. Produktua amaitu daview

The Leviton DT130-1LW Countdown Timer Switch is designed to replace standard wall switches, providing automated control for various electrical loads such as bathroom exhaust fans, household lights, heat lamps, and towel warmers. This single-pole switch features four preset time options (5, 10, 15, and 30 minutes) and a manual off button, ensuring devices turn off automatically to conserve energy.

Key features include a slim design for easy installation in wall boxes, interchangeable line and load wires to simplify wiring, and an innovative Green Flex Sleeve for flexible grounding or neutral wire connections.

Leviton DT130-1LW Countdown Timer Switch

1. irudia: Aurrealdea view of the Leviton DT130-1LW Countdown Timer Switch.

2. Segurtasun informazioa

  • OHARRA: Sutea, deskarga elektrikoa edo heriotza saihesteko, itzali korrontea etengailutik edo fusible-kutxatik eta egiaztatu korrontea itzalita dagoela kableatu aurretik.
  • Instalazioa elektrizista kualifikatu batek edo tokiko araudi elektrikoen arabera egin behar du.
  • Erabili kobrezko alanbrea soilik.
  • Do not use with dimmable loads if it is the only light source in the area.
  • A ground wire is required for installation.

3. Instalatzeko jarraibideak

3.1 Beharrezko tresnak

  • Bihurkin (Phillips eta Flathead)
  • Hari-ebakitzaileak
  • Zinta Elektrikoa
  • Kontakturik gabeko Voltage Probatzailea

3.2 Kablearen urratsak

  1. Itzali energia: Locate the circuit breaker or fuse that controls the switch you are replacing and turn it OFF. Verify power is off using a non-contact voltage probatzailea.
  2. Kendu etengailu zaharra: Carefully remove the existing wall plate and unscrew the old switch from the wall box. Disconnect the wires from the old switch, noting which wires were connected to the line (power in) and load (power out) terminals, as well as the ground wire.
  3. Hariak prestatu: Strip approximately 1/2 inch of insulation from each wire end if necessary.
  4. Konektatu lurreko kablea: The DT130-1LW requires a ground connection. Connect the green ground wire from the timer switch to the bare copper or green insulated ground wire in the wall box. If no neutral wire is available, the Green Flex Sleeve on the timer's white wire should remain on, and this white wire should be connected to the ground bundle. If a neutral wire is present, remove the Green Flex Sleeve and connect the white wire to the neutral bundle.
  5. Leviton DT130-1LW Wiring Diagram with Green Flex Sleeve

    Figure 2: Wiring diagram showing the Green Flex Sleeve for ground or neutral connection.

  6. Connect Line and Load Wires: The DT130-1LW has two black wires that are interchangeable for line and load connections. Connect one black wire from the timer switch to the line (power in) wire from the wall box and the other black wire from the timer switch to the load (power out) wire. Secure connections with wire nuts or appropriate connectors.
  7. Leviton DT130-1LW Wiring Example

    3. irudia: Adibample of connecting the timer switch wires to the household wiring.

  8. Muntaketa-etengailua: Carefully push all wires back into the wall box. Secure the timer switch to the wall box using the provided screws.
  9. Instalatu horma-plaka: Attach a compatible Decora wall plate (sold separately) over the timer switch.
  10. Berrezarri boterea: Piztu berriro korrontea etengailu elektrikoan edo fusible-kutxan.

3.3 Instalazio bideo gida

Video 1: A step-by-step guide on how to install the Leviton Countdown Timer Switch, including wiring connections and safety precautions.

3.4 Green Flex Sleeve Explanation

Video 2: An explanation of Leviton's Green Flex Sleeve, detailing its use for grounding when a neutral wire is absent or connecting to a neutral wire when present.

4. Funtzionamendu-argibideak

The Leviton DT130-1LW features intuitive push-button operation for setting countdown times.

  • Aurrez ezarritako botoiak: The switch has four buttons labeled 5M, 10M, 15M, and 30M, corresponding to 5, 10, 15, and 30 minutes respectively. Press any of these buttons to activate the connected device for the selected duration. The device will automatically turn off when the time expires.
  • Manual Off Button: The bottom button acts as a manual OFF switch. Press it at any time to turn off the connected device before the countdown completes.
  • LED adierazleak: Small LEDs next to each button illuminate to indicate the active countdown setting.
Leviton DT130-1LW Timer Switch Features

Figure 4: Labeled features of the timer switch, including preset buttons and LED indicators.

Video 3: A brief demonstration of the Leviton Countdown Timer Switch's one-touch operation and preset options.

5. Mantentzea

The Leviton DT130-1LW Countdown Timer Switch requires minimal maintenance.

  • Garbiketa: To clean the switch, wipe with a soft, damp zapirik. Ez erabili garbitzaile edo disolbatzaile urratzailerik. Ziurtatu argindarra itzalita dagoela garbitu aurretik.
  • Faceplate Replacement: The faceplate can be removed for color changes using DTKIT faceplates (sold separately). Refer to the installation section for guidance on handling the switch.
  • Leviton DT130-1LW Faceplate Replacement

    Figure 5: Illustration of how to change the faceplate for aesthetic customization.

6. Arazoak

  • Gailua ez da pizten:
    • Ziurtatu zirkuitu-hauslean korrontea piztuta dagoela.
    • Verify all wire connections are secure and correct.
    • Check if the connected load (bulb, fan) is functional.
  • Timer does not turn off automatically:
    • Confirm the correct preset button was pressed.
    • Ensure the switch is not damaged.
  • Argi keinukariak:
    • This timer is not designed for use with dimmable loads if it is the only light source. Ensure compatible load types are connected.

Arazoak jarraitzen badute, kontsultatu elektrizista kualifikatu bati.

7. Zehaztapenak

EzaugarriXehetasuna
Modelo zenbakiaDT130-1LW
Eragiketa moduaAutomatic Countdown
Egungo balorazioa15 Amps
Bolumen eragileatage120 Volt
Kontaktu motaNormalean irekita
Konektore motaHari-buruak
TerminalaTorlojua
Zirkuitu Mota1-way (Single Pole)
Eragile motaSakatu botoia
Produktuaren neurriak (L x W x H)4.13 x 1.73 x 1.34 hazbete
Karga-bateragarritasuna600W LED/CFL, 1800W Incandescent/Halogen, 1200VA MLV/ELV/Fluorescent, ½ HP/9.8 Amp Fan/Motor, 15A Resistive
Leviton DT130-1LW Dimensions

Figure 6: Detailed dimensions of the Leviton DT130-1LW Countdown Timer Switch.

8. Bermea eta Laguntza

For warranty information and technical support, please visit the official Leviton webwebgunera edo jarri harremanetan bezeroarentzako arreta-zerbitzura. Gorde erosketa-agiria berme-erreklamazioetarako.

Sareko baliabideak: www.leviton.com

© 2023 Leviton Manufacturing Co., Inc. Eskubide guztiak erreserbatuta.

Erlazionatutako dokumentuak - DT130-1LW

Aurreview Leviton Electronic Countdown Timer Switch Installation and Operation Manual
Comprehensive installation and operation guide for Leviton Electronic Countdown Timer Switches (Models DT115, DT130, DT160, DT102, DT104, DT112). Includes wiring instructions, troubleshooting, and specifications.
Aurreview Minoston MT10W Wi-Fi atzerako kontaketa tenporizadorearen etengailuaren erabiltzailearen gida
Ikasi Minoston MT10W Wi-Fi atzerako kontagailuaren etengailua nola instalatu eta erabili etxe adimendunen automatizaziorako. Gida honek aplikazioaren deskarga, konfigurazioa, Amazon Alexa eta Google Assistant-ekin ahots-kontrolaren bateragarritasuna eta segurtasun-argibide garrantzitsuak azaltzen ditu.
Aurreview AmazonCommercial Atzerako Kontaketa Tenporizadorearen Etengailuaren Erabiltzaile Eskuliburua
AmazonCommercial Countdown Timer Switch-erako erabiltzailearen eskuliburu zehatza, hainbat denbora-ezarpen eta eskuzko gainidazketa-funtzioetarako konfigurazio, funtzionamendu eta segurtasun-argibideak eskaintzen dituena.
Aurreview Sunco 5/6" LED 15W-ko Beheko Argi Diskoaren Erabiltzaile Eskuliburua eta Instalazio Gida
Sunco 5/6" LED 15W Downlight Disk-erako (SKU: DL_DK56-15W) erabiltzailearen eskuliburu eta instalazio gida osoa, segurtasuna, gainazaleko eta berritzeko muntaketarako instalazio urratsak, arazoak konpontzea, produktuaren zehaztapenak eta gomendatutako dimmerrak jorratzen dituena.
Aurreview LogiLink Kanpoko Atzerako Kontaketa Tenporizadorea ET0015 - Energia Aurrezteko Soluzioa
Ezagutu LogiLink ET0015 Kanpoko Atzerako Kontaketa Tenporizadorea, barruko eta kanpoko erabilerarako energia aurrezteko irtenbide polifazetikoa. Automatizatu zure etxetresna elektrikoak 20 minututik 12 ordura bitarteko tenporizadore programa pertsonalizagarriekin, IP44 zipriztinen aurkako babesarekin eta zirkuitulaburreko babesarekin.
Aurreview BN-LINK BNH-60/U92 Atzerako kontaketa tenporizadore mekanikoa - Ezaugarriak eta zehaztapenak
BN-LINK BNH-60/U92 atzerako kontaketa mekanikoaren tenporizadorearen zehaztapen zehatzak, ezaugarriak, balorazioak eta ontziratzeari buruzko informazioa. Barruko erabilerarako aproposa, 12 orduko atzerako kontaketa eta 15 minutuko ezarpen-tartearekin.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.