1. Sarrera
This manual provides detailed instructions for the installation, operation, and maintenance of your NCLTHS Access Control System. This kit is designed to provide secure and convenient access management for various indoor applications. Please read this manual thoroughly before installation and operation to ensure proper functioning and safety.
2. Segurtasun informazioa
- Segurtasun elektrikoa: The power supply unit contains hazardous voltage. Do not open the power supply cover. All wiring should be performed by qualified personnel to prevent electric shock or damage to the system.
- Instalazioa: Ensure all components are securely mounted. Improper installation of the magnetic lock or strike plate can compromise security and system performance.
- Energia iturria: Use only the provided 110-240VAC to 12VDC power supply. Connecting to an incorrect power source may damage the unit.
- Ingurumena: This system is recommended for indoor use. Avoid exposure to moisture, extreme temperatures, or corrosive environments.
- Larrialdietarako sarbidea: Always ensure there is an alternative method for emergency exit in case of power failure or system malfunction.
3. Paketearen edukia
Egiaztatu behean zerrendatutako elementu guztiak zure paketean sartuta daudela:
- 1 x 600LBS Electric Magnetic Lock
- 1 x Access Control Keypad
- 1 x Doorbell Chime
- 2 x Urrutiko igorleak
- 1 x Remote Receiver
- 5 x RFID Keyfobs
- 1 x Ingelesezko erabiltzailearen eskuliburua (dokumentu hau)
- 1 x Power Supply Control Unit
- 1 x Push to Exit Button

Figure 3.1: All included components of the NCLTHS Access Control System kit.
4. Konfigurazioa eta instalazioa
Careful installation is crucial for the proper functioning and security of your access control system. Ensure all connections are secure and correct before applying power.
4.1 Osagaia amaitu daview

Sarbide Kontrol Teklatua

600lbs Magnetic Lock

Txirrinaren txirrinak

Push to Exit Button

Urruneko hargailua

Urruneko igorlea

Power Supply Control Unit
4.2 Kableatu-diagrama
Refer to the following wiring diagrams for connecting the components. Ensure all wires are correctly identified and connected to the appropriate terminals on the power supply, keypad, and other devices.

Figure 4.2.1: Comprehensive Wiring Diagram for the Access Control System.

Figure 4.2.2: Simplified Wiring Overview.
4.3 Instalazio-urratsak
- Mount the Magnetic Lock: Install the electromagnetic lock on the door frame and the armature plate on the door. Ensure proper alignment for secure locking. Mounting brackets (not included) may be required depending on your door type and frame.
- Mount the Access Control Keypad: Secure the keypad near the entry point, typically on the outside of the door.
- Mount the Exit Button: Install the push-to-exit button on the inside of the door, allowing for easy egress.
- Install the Power Supply Control Unit: Mount the power supply unit in a secure, accessible location, ensuring it is protected from environmental factors.
- Konektatu kableatzea: Follow the wiring diagrams carefully. Connect the magnetic lock, keypad, exit button, doorbell, and remote receiver to the power supply control unit. Pay close attention to positive (+12V), negative (GND), Normally Open (NO), and Normally Closed (NC) connections.
- Konektatu energia: Once all components are wired, connect the power supply unit to a 110-240VAC power source.
- Proba sistema: After installation, test all functions: keypad entry, RFID card entry, remote control operation, and exit button release.
Video 4.3.1: Detailed installation and wiring guide for the Access Control System. This video demonstrates the connection process for various components.
5. Funtzionamendu-argibideak
5.1 Teklatuaren funtzionamendua
The keypad allows access via a numerical code or RFID card/keyfob.
- Default Access Code: The default access code is typically 1234.
- Entering an Access Code: Enter your 4-digit code followed by the '#' key. The door will unlock for a preset duration.
- Adding User Codes:
- Enter Programming Mode: Press '*' then enter the Master Code (default: 123456) then '#'.
- Add User Code: Press '1' then enter a 3-digit User ID (e.g., 001) then '#'. Enter the new 4-digit User Code then '#'. Repeat for additional users.
- Exit Programming Mode: Press '*' to save and exit.
- Adding RFID Cards/Keyfobs:
- Enter Programming Mode: Press '*' then enter the Master Code (default: 123456) then '#'.
- Add Card: Press '1' then present the RFID card/keyfob to the keypad. The keypad will beep to confirm. Repeat for additional cards.
- Exit Programming Mode: Press '*' to save and exit.
- Deleting User Codes/Cards: Consult the specific keypad manual for detailed instructions on deleting individual users or resetting the keypad.

Figure 5.1.1: RFID Keyfobs and Cards.
5.2 Urruneko kontrolaren funtzionamendua
The remote transmitters allow convenient unlocking from a distance.
- Urrutiko aginteen parekatzea: The remotes are typically pre-paired with the receiver. If re-pairing is needed, refer to the remote receiver's specific instructions. Usually, this involves pressing a learning button on the receiver and then a button on the remote.
- Desblokeatzea: Press the unlock button on the remote transmitter. The door will momentarily unlock.
5.3 Exit Button Operation
The push-to-exit button provides a simple way to exit from the secured area.
- Irteera: Press the exit button. The magnetic lock will disengage, allowing the door to open.
6. Mantentzea
Regular maintenance ensures the longevity and reliable performance of your access control system.
- Garbiketa: Clean the keypad and magnetic lock surfaces with a soft, dry cloth. Avoid abrasive cleaners or solvents.
- Egiaztatu konexioak: Aldian-aldian ikuskatu kableatu-konexio guztiak, ondo finkatuta daudela eta korrosiorik gabe daudela ziurtatzeko.
- Magnetic Lock Alignment: Ensure the magnetic lock and armature plate remain properly aligned. Misalignment can reduce holding force.
- Battery Replacement (Remotes): If remote controls become unresponsive, replace their internal batteries.
7. Arazoak
Sarbide-kontrol sistemarekin arazoak badituzu, jo ezazu honako arazo eta irtenbide ohikoenei:
| Arazoa | Kausa posiblea | Irtenbidea |
|---|---|---|
| Magnetic lock does not engage or holds weakly. | Incorrect wiring; insufficient power; misalignment of lock and armature plate; improper mounting. | Verify all wiring connections (refer to Section 4.2). Ensure the power supply is providing stable 12VDC. Check alignment and adjust if necessary. Confirm the magnetic lock and armature plate are securely mounted, potentially requiring appropriate brackets for your door type. |
| Keypad is unresponsive or not powering on. | No power to keypad; faulty wiring; keypad malfunction. | Check power connections to the keypad from the power supply. Ensure the power supply unit is receiving input power. Verify wiring integrity. |
| Cannot add more than 4 users to the keypad. | Keypad user capacity limit reached; incorrect programming steps. | Some keypads have a limited number of user slots. Consult the specific keypad's detailed manual for its maximum user capacity and advanced programming options. Ensure you are following the correct sequence for adding users (Section 5.1). |
| Remote control does not unlock the door. | Remote battery low/dead; remote not paired; remote receiver issue. | Replace the battery in the remote transmitter. Re-pair the remote with the receiver (refer to Section 5.2). Check wiring to the remote receiver. |
| Exit button does not release the lock. | Incorrect wiring; faulty button. | Verify wiring connections for the exit button to the power supply control unit. Test the button for continuity if possible. |
8. Zehaztapenak
| Ezaugarri | Xehetasuna |
|---|---|
| Marka | NCLTHS |
| Ereduaren izena | Sarbide Kontrol Sistema |
| Modelo zenbakia | Electric Magnetic Door Lock Kit |
| Blokeo mota | Combination Lock (Magnetic) |
| Euste-indarra | 600 LBS (280 kg) |
| Materiala | Aluminioa |
| Elikatze Hornidura Sarrera | 110-240 VAC, 50 Hz |
| Elikatze Hornidura Irteera | 12VDC, 4A |
| Erabilera gomendatua | Barruan |
| Ezaugarri Berezia | Blokeo automatikoa |
| Kontrol-metodoa | Touch (Keypad), Hand Control (Remote, Exit Button) |
| Konektibitate-protokoloa | Z-Wave (Note: This may refer to the keypad's internal capability, not necessarily an included Z-Wave hub) |
| Elementuaren neurriak (L x W x H) | 12 x 8 x 3.5 inches (Overall kit packaging) |
| GTIN | 716841008746 |
| ASIN | B0CW9NRSTP |
9. Bermea eta Laguntza
For warranty information, please refer to the terms and conditions provided at the time of purchase or contact your retailer. If you require technical assistance or have questions not covered in this manual, please contact the manufacturer or seller directly. Keep your purchase receipt as proof of purchase for any warranty claims.