Goodman GLXS3BN6010CAPTA6030C3

Goodman GLXS3BN6010 / CAPTA6030C3 5 tonako 13.4 SEER2 R-32 AC sistemaren instrukzio eskuliburua

Model: GLXS3BN6010 (Condenser) and CAPTA6030C3 (Coil)

Marka: Goodman

Produktua amaituview

This document provides essential information for the Goodman 5 TON 13.4 SEER2 R-32 AC Only System, which includes the GLXS3BN6010 Air Conditioner condenser and the CAPTA6030C3 vertical coil. This system is designed for cooling applications and is certified by AHRI under certificate number 215271993. Please note that this is a partial system and requires a compatible furnace or modular blower to make a complete system.

Goodman 5 Ton AC Only System with Condenser and Vertical Coil

Image: Goodman 5 Ton AC Only System, showing the outdoor condenser unit and the indoor vertical coil unit.

Important Refrigerant Information: R-32

As of January 1st, 2025, a new refrigerant, R-32, is being introduced for residential air conditioning systems. R-32 has been used in the automotive industry for many years and offers several advantages:

  • Eraginkortasun handiagoa: R-32 is approximately 40% more efficient, meaning less refrigerant is needed per system.
  • Berotze Globalaren eragin txikiagoa: It has a smaller global warming potential compared to previous refrigerants.
  • Sukotasuna: R-32 is slightly flammable. If a refrigerant leak is detected in a system paired with a furnace, a compatible "Dragonfly kit" is required to communicate with the furnace and shut off the burner to prevent ignition. This is a rare but important safety consideration.

Bateragarritasun oharra: R-410A systems are not backwards compatible with R-32. If you are replacing either the outdoor condenser or the indoor coil, both components must be replaced together to ensure compatibility with R-32 refrigerant. New furnaces are generally compatible with R-32 systems.

Video: R-32 Fact vs Fiction. This video provides an overview of R-32 refrigerant, addressing common misconceptions and highlighting its benefits and safety considerations.

Video: Information about refrigerant regulations. This video explains the regulatory changes concerning refrigerants like R-32.

System Components and Types

This Goodman system is an AC-only split system, consisting of an outdoor condenser (GLXS3BN6010) and an indoor vertical coil (CAPTA6030C3). It requires a separate furnace or modular blower for a complete heating and cooling solution.

Goodman 5 Ton AC System Specifications

Irudia: Gainetikview of Goodman 5 Ton AC System specifications, including tonnage, efficiency, type, region, flow, AHRI certification, warranty, and R-32 refrigerant.

Goodman GLXS3BN6010 Condenser Specifications

Image: Detailed specifications for the Goodman GLXS3BN6010 condenser, including tonnage, efficiency, type, dimensions, weight, lineset, warranty, and R-32 refrigerant.

Goodman CAPTA6030C3 Coil Specifications

Image: Detailed specifications for the Goodman CAPTA6030C3 coil, including tonnage, connections, dimensions, weight, orientation, warranty, and R-32 refrigerant.

Types of HVAC Systems:

Understanding your existing HVAC system is crucial for proper installation and compatibility. Common types include:

  • Zatiketa sistema: Consists of an outdoor unit (condenser) and an indoor unit (coil and air handler/furnace) connected by refrigerant lines. This Goodman system is a component of a split system.
  • Ductless System (Mini-Split): Features an outdoor unit connected to one or more indoor wall-mounted units, without extensive ductwork.
  • Package Unit: All components (condenser, coil, blower, and heating element) are contained within a single outdoor unit, typically installed on a roof or concrete pad.

Video: What type of system do you have? This video helps identify different HVAC system configurations.

Video: Condenser with Coil Combination. This video explains the interaction between the condenser and coil in an AC system.

Konfigurazioa eta Instalazioa

Installation of this Goodman AC system must be performed by a qualified and certified HVAC professional. Improper installation can lead to system malfunction, safety hazards, and void the warranty.

Oinarri nagusiak:

  • System Matching: The GLXS3BN6010 condenser and CAPTA6030C3 vertical coil are designed to work together. Ensure your furnace or modular blower is compatible with this R-32 system.
  • Coil Orientation: The CAPTA6030C3 is a vertical coil (A-coil), suitable for upflow or downflow furnace configurations. If your furnace is horizontal, a horizontal coil is required.
  • Hozgarri-lerroak: Proper sizing and installation of refrigerant lines are critical for system performance and efficiency.
  • Konexio elektrikoak: All electrical wiring must comply with local codes and be performed by a licensed electrician.
  • Drainatzea: Ensure proper condensate drainage from the indoor coil to prevent water damage.

Regional Compliance: This system does not comply with Federal regulations for installation in the following states: AL, AR, AZ, CA, DE, FL, GA, KY, LA, MD, MS, NC, NM, NV, OK, SC, TN, TX, and VA. Installation in these states is prohibited.

Zure sistema eragilea

Once installed by a qualified professional, your Goodman AC system is designed for reliable cooling. Familiarize yourself with your thermostat's operation to control temperature settings and fan modes.

SEER2 Efficiency Standards:

The Seasonal Energy Efficiency Ratio 2 (SEER2) is a new standard set by the U.S. Department of Energy to more accurately reflect real-world energy efficiency. This Goodman system has a 13.4 SEER2 rating.

  • North Region: A minimum of 13.4 SEER2 is required.
  • Hegoaldeko eskualdea: A minimum of 14.3 SEER2 is required.

Always ensure your system meets the minimum SEER2 requirements for your geographical region. Higher SEER2 ratings generally indicate greater energy efficiency and potential long-term savings on utility bills.

EnergyGuide Label for Goodman GLXS3BN6010A

Image: EnergyGuide label for the Goodman GLXS3BN6010A model, showing an efficiency rating of 13.40 SEER2 and indicating allowed installation states for the North Region.

Video: SEER2 Regulations - 02. This video explains the updated SEER2 efficiency standards.

Mantentzea

Regular maintenance is essential to ensure the longevity and efficient operation of your Goodman AC system. It is recommended to schedule annual inspections and tune-ups with a qualified HVAC technician.

Erabiltzaileen mantentze-lanak:

  • Iragazkiaren ordezkoa: Regularly check and replace your furnace/air handler filter every 1-3 months, or more frequently if you have pets or allergies.
  • Clear Outdoor Unit: Keep the area around the outdoor condenser unit free from debris, leaves, and vegetation to ensure proper airflow.
  • Hustubide-hodiaren egiaztapena: Periodically check the condensate drain line for clogs.

Mantentze profesionala:

A professional technician can perform comprehensive checks, including refrigerant levels, electrical connections, coil cleaning, and overall system performance to prevent potential issues.

Arazoak konpontzea

If your system is not operating correctly, consider the following basic troubleshooting steps before contacting a technician:

  • Hozterik ez: Check your thermostat settings to ensure it's set to "Cool" mode and the temperature is below the current room temperature. Verify the circuit breaker for the HVAC system hasn't tripped.
  • Aire-fluxu eskasa: Check and replace dirty air filters. Ensure no vents are blocked.
  • Ezohiko zaratak: Strange noises can indicate various issues. Turn off the system and contact a professional for diagnosis.
  • Ur-ihesak: Check the condensate drain pan and line for blockages.

For any issues beyond basic checks, it is strongly recommended to contact a qualified HVAC technician to avoid further damage or safety risks.

Zehaztapenak

EzaugarriXehetasuna
MarkaGoodman
Ereduaren izenaGLXS3BN6010CAPTA6030C3
Edukiera5 tona
Sasoiko energia-eraginkortasunaren ratioa (SEER2)13.4
HozgarriaR-32
Iragazki motaIragazki lehorgailua
Energia iturriaKable elektrikoa
Forma-faktoreaZatiketa Sistema
Instalazio motaZatiketa Sistema
KoloreaBeltza
EraginkortasunaAlta
AHRI ziurtagiri zenbakia215271993

Bermearen informazioa

This Goodman AC system comes with a 10 urteko piezen berme mugatua. To validate the warranty, the system must be installed by a qualified installer and registered online within 60 days of installation. Online registration is not required in California.

10 Urteko Berme Mugatuaren Ezkutua

Image: A shield graphic indicating a 10-year limited warranty.

For complete warranty details and terms, please contact the seller or refer to the official Goodman warranty documentation.

Laguntza eta Harremana

For any questions regarding installation, operation, maintenance, or warranty claims, please contact Superior Home Supplies, the seller of this product. They are available to assist with product-related inquiries.

Saltzailea: Superior Home Supplies

For general information about Goodman products, you may visit the Goodman denda Amazonen.

© 2024 Goodman. Eskubide guztiak erreserbatuta.

Erlazionatutako dokumentuak - GLXS3BN6010CAPTA6030C3

Aurreview Goodman GPCH3 Aire Girotu Ontziratuaren Ezaugarriak eta Zehaztapenak
Goodman GPCH3 serieko aire girotu ontziratuen gida osoa, ezaugarri estandarrak eta kabineteko ezaugarriak, nomenklatura, produktuaren zehaztapen zehatzak, hozte eta aire-fluxuaren datu zabalduak, berogailu-kiten informazio elektrikoa, neurriak, kableatu-diagramak eta eskuragarri dauden osagarriak biltzen dituena. Eraginkortasunerako eta iraunkortasunerako diseinatuta, unitate hauek 2 eta 5 tona arteko tarteetan daude eskuragarri, 13.4 SEER2 balorazioekin.
Aurreview Goodman GPCH3 Serieko Aire Girotu Ontziratua - Zehaztapenak eta Datuak
Goodman GPCH3 serieko aire girotu ontziratuen gida osoa, 2 eta 5 tona arteko unitateen zehaztapenak, nomenklatura, aire-fluxua, datu elektrikoak, neurriak eta osagarriak zehaztuz, 13.4 SEER2 eraginkortasunarekin.
Aurreview Goodman GPHH5 Bero-ponpa ontziratuak: zehaztapenak eta ezaugarriak
Osoa baino gehiagoview Goodman GPHH5 Serieko Bero Ponpa Ontziratuei buruzko informazioa, ezaugarri estandarrak eta kabinetearen ezaugarriak, modeloaren nomenklatura, SEER2 balorazioak barne hartzen dituzten zehaztapen nagusiak, hozte/berotze ahalmenak, aire-fluxuaren datuak, eskakizun elektrikoak, neurriak, eskuragarri dauden osagarriak eta bermearen informazioa zehaztuz.
Aurreview Goodman GPG13 Gas/Elektrizitate Unitate Ontziratuaren Produktuaren Zehaztapenak
Goodman GPG13 serieko gas/elektrizitate unitate monofasiko eta autonomoen produktuaren zehaztapen zehatzak, ezaugarriak, armairuaren xehetasunak, nomenklatura, zehaztapenak, neurriak, kableatu-diagramak eta osagarriak barne hartzen dituztenak.
Aurreview Goodman GPHH3 Bero-ponpa ontziratua: zehaztapenak eta errendimendu-datuak
Goodman GPHH3 serieko bero-ponpa ontziratuen zehaztapen zehatzak, errendimendu-datuak eta ezaugarriak, hozte- eta berotze-ahalmena, aire-fluxua, datu elektrikoak, neurriak eta osagarriak barne.
Aurreview Goodman & Amana Split System HVAC Zerbitzu Argibideak R-22 Unitateetarako
Goodman eta Amana sistema zatituetako aire girotu eta bero-ponpetarako zerbitzu-argibideen eskuliburu osoa, R-22 hozgarria erabiltzen dutenak. Produktuaren identifikazioa, diseinua, sistemaren funtzionamendua, arazoak konpontzea eta HVAC teknikari kualifikatuentzako mantentze-prozedura zehatzak biltzen ditu.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.