Garvee 2026 NEW-12K-115V-22 SEER2-WIFI 2.0

GarveeHome 12000 BTU Inverter Split System Air Conditioner User Manual

Model: 2026 NEW-12K-115V-22 SEER2-WIFI 2.0

1. Sarrera

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your GarveeHome 12000 BTU Inverter Split System Air Conditioner. Please read this manual thoroughly before installation and use, and retain it for future reference.

The GarveeHome 12000 BTU Inverter Split System is a versatile unit designed for energy-efficient cooling and heating, suitable for spaces up to 750 square feet. It features inverter technology, multiple operating modes, and smart Wi-Fi control.

2. Segurtasun informazioa

Segurtasun-argibide garrantzitsuak:

  • Installation must be performed by a qualified professional to prevent electric shock, fire, or serious injury.
  • Ziurtatu elikatze-iturria unitatearen zehaztapenekin bat datorrela (115V).
  • Do not attempt to repair or modify the air conditioner yourself. Contact qualified service personnel.
  • Aire-fluxu egokia bermatzeko, kanpoko unitatearen inguruko eremua oztoporik gabe mantendu.
  • Ez sartu objekturik aire-irteeran edo sarreran.
  • Ziurtatu lurrerako egokia den arrisku elektrikoak saihesteko.
  • Regularly clean air filters to maintain efficiency and air quality.

3. Paketearen edukia

Instalazioa hasi aurretik, egiaztatu osagai guztiak daudela.

Package list for GarveeHome Mini Split AC showing indoor unit, outdoor unit, pipes, wires, remote, and user manual.

3.1. irudia: Paketeen zerrenda - This image displays the main components included in the package: the indoor unit, outdoor unit, copper connection pipes (air and liquid), power line, communication wire, drain pipe, remote control, user manual, tape, and putty.

  • Barne Unitatea
  • Kanpoko Unitatea
  • 13 ft Copper Connection Pipe (Air Pipe)
  • 13 ft Copper Connection Pipe (Liquid Pipe)
  • 8 oineko linea elektrikoa
  • 15 oineko komunikazio-kablea
  • 6.5 ft Drain Pipe
  • Urruneko Kontrola
  • Erabiltzailearen eskuliburua (dokumentu hau)
  • Zinta
  • Luting (Putty)

4. Instalazio gida

Installation of this split system requires specialized tools and knowledge. It is highly recommended that installation be performed by a certified HVAC professional.

4.1 Barruko Unitatearen Instalazioa

The wall for the indoor unit installation must be hard and firm to prevent vibration. Ensure adequate clearance around the unit for proper airflow and maintenance.

Diagram showing recommended clearances for indoor unit installation: 15cm above ceiling, 20cm above side walls, 230-260cm above floor.

Figure 4.1: Indoor Unit Clearance Requirements - This diagram illustrates the minimum recommended distances from the indoor unit to the ceiling, side walls, and floor to ensure optimal operation and maintenance access.

  1. Muntatzeko plaka instalatzea: Drill holes and use appropriate screws to fasten the mounting plate horizontally and vertically on the wall.
  2. Wall Hole for Piping: Create a wall hole (typically Ø60mm-Ø80mm) for refrigerant piping, ensuring it slopes slightly downward to facilitate drainage. Avoid pre-buried power wires or hard wall sections.
  3. Elikatze-kablearen konexioa: Pass the power cable from the back of the indoor unit to the terminal board. Secure the cable with a clamp.
  4. Hodiaren konexioa: Connect the connecting pipes to the indoor unit. Aim at the pipe center, tighten the taper nut with fingers, then use a torque wrench to secure it according to the specified torque values (refer to the table in the video for pipe size and torque). Carefully check for any damage to joints before installation. Do not reuse joints unless re-flared.
  5. Insulation and Sealing: Use insulation sleeves to wrap the joint parts of the indoor unit and connection pipes. Seal insulation material to prevent condensate water generation.
  6. Hustuketa mahuka konexioa: Connect the water outlet with the drain pipe, ensuring the drain hose is straight and slopes downward.
  7. Wrapping Pipes and Cables: Use plastic cable ties to wrap the connecting pipes, cables, and drain hose together. Run the assembly sloping downward.
  8. Refrigerant Piping Through Wall: Carefully guide the wrapped refrigerant piping through the wall hole.
  9. Mounting Indoor Unit: Hang the indoor unit on the mounting plate. Move it from left to right to ensure the hooks are properly positioned.
  10. Sealing Wall Hole: Install a pipe protecting ring and seal the wall hole with putty to prevent air and moisture infiltration.

4.2 Kanpoko Unitatearen Instalazioa

The outdoor unit should be installed in a location that meets the specified clearance requirements for optimal performance and maintenance.

Outdoor unit of the GarveeHome Mini Split AC, showing its robust design for all-weather operation.

Figure 4.2: Outdoor Unit Placement - This image shows the outdoor unit. Ensure adequate space around the unit for proper airflow: 50cm above, 10cm on the air intake side, 50cm to other obstructions, 30cm above the ground, and 200cm clear space for air discharge.

  1. Muntatzeko euskarriaren instalazioa: Use at least 6 expansion bolts to fix the mounting brackets firmly on the wall. Ensure the brackets are level.
  2. Positioning Outdoor Unit: Carefully place the outdoor unit onto the installed brackets.
  3. Securing Outdoor Unit: Use 4 screws to fix the feet of the outdoor unit onto the brackets.
  4. Connecting Refrigerant Pipes: Remove the nuts from the stop valves. Aim at the pipe center of the stop valves and tighten the taper nuts with fingers. Then, use two wrenches to fully tighten the taper nuts.
  5. Konexio elektrikoak: Remove the electrical box cover. Connect the cables respectively to the corresponding terminals of the terminal board of the outdoor unit (refer to the wiring diagram provided in the unit's documentation). Ensure the ground wire is securely connected. Fix all cables reliably with fasteners.
  6. Sistema xurgatzea: Fully open the handle Lo of the manifold valve and apply vacuum for at least 15 minutes. Check that the compound vacuum gauge reads -0.1MPa (-76cmHg).
  7. Opening Stop Valves: After applying vacuum, fully open the stop valves with a hex wrench. Be sure to retighten the caps afterward to prevent potential air leakage.
  8. Securing Caps: Screw all the caps back onto the stop valves and tighten them securely.

4.3 Instalazio bideo gida

Watch this official installation video for a visual step-by-step guide on setting up your GarveeHome Mini Split AC system.

Video 4.1: Garvee Mini Split AC Installation Guide - This video demonstrates the complete installation process for the Garvee 12000 BTU Mini Split AC/Heating System, covering both indoor and outdoor unit setup, piping, electrical connections, and vacuuming.

5. Funtzionamendu-argibideak

Your GarveeHome Mini Split AC offers various modes and features for personalized comfort.

5.1 Urruneko kontrolaren funtzioak

Image of the GarveeHome Mini Split AC remote control with various function icons: Cooling, Heating, Dry, Fan Only, Display On/Off, Sleep, ECO Energy Saving, Self-Cleaning, °C/°F, 24H Timer, 4D Auto Swing.

Figure 5.1: Multifunctional Remote Control - This image displays the remote control for the GarveeHome Mini Split AC, highlighting its various buttons and functions for controlling the unit's modes and settings.

  • Cool modua: Hozte azkarra eskaintzen du.
  • Bero modua: Offers fast heating.
  • Modu lehorra: One-key drying mode to quickly reduce indoor humidity.
  • Fan soilik modua: Selectable low, mid, high, or turbo fan speeds with up to 50ft long-distance airflow.
  • Pantaila piztu/desaktibatu: Toggles the unit's display.
  • Lo egiteko modua: Adjusts temperature for comfortable sleep and quiet operation (41 dB). The remote display turns off automatically after 10 seconds of inactivity.
  • ECO Energy Saving Mode: Energia-kontsumoa murrizteko funtzionamendua optimizatzen du.
  • Autogarbiketa: Initiates an automatic cleaning cycle.
  • °C/°F: Switches between Celsius and Fahrenheit temperature display.
  • 24 orduko tenporizadorea: Automatikoki pizteko/itzaltzeko tenporizadorea ezartzen du.
  • 4D Auto Swing: Controls the automatic swing of the air deflector for wider air distribution.
  • iFEEL modua: Urrutiko agintearen kokapeneko tenperatura hautematen du erosotasun zehatza lortzeko.

5.2 Wi-Fi Smart Control

Image showing a smartphone app controlling the GarveeHome Mini Split AC, with icons for WiFi 2.0, Works With Amazon Alexa, and Works With Google Assistant.

Figure 5.2: Smart Control via App - This image illustrates the capability of controlling the GarveeHome Mini Split AC using a smartphone application, highlighting compatibility with Wi-Fi 2.0, Amazon Alexa, and Google Assistant.

The unit supports Wi-Fi 2.0 for smart control. Download the GarveeHome app (or compatible smart home app) to connect your unit. You can remotely adjust temperatures, change modes, and monitor your AC from anywhere. The system is compatible with Google Home for voice control.

5.3 Energy Efficiency and Performance

  • Inbertsore teknologia: Innovative inverter technology ensures optimal performance with up to 25% energy savings.
  • Funtzionamendu-tenperatura-tarte zabala: Designed to perform in various environments, with low-temperature startup at -4°F (-20°C) and stable operation up to 140°F (60°C).
  • Tenperaturaren kontrol zehatza: AI intelligent sensing of ambient temperature allows for precise control within ±0.1°C.
  • Funtzionamendu isila: 41 dB-ko zarata-maila baxuan funtzionatzen du, ingurune lasaia bermatuz.

6. Mantentzea

Mantentze-lan erregularrak zure aire girotuaren iraupena eta funtzionamendu eraginkorra bermatzen ditu.

6.1 Iragazkien garbiketa

Air filters should be cleaned regularly (e.g., every two weeks) to maintain optimal airflow and air quality.

  1. Ireki barruko unitatearen aurrealdeko panela.
  2. Kendu aire-iragazkiak.
  3. Clean the filters with a vacuum cleaner or wash them with lukewarm water.
  4. Utzi iragazkiak guztiz lehortzen berriro sartu aurretik.
  5. Itxi aurrealdeko panela.

6.2 Auto-garbiketa funtzioa

Diagram illustrating the 57°C high temperature self-cleaning and sterilization process of the indoor unit, showing condensation, frosting, defrosting, and sterilization stages.

Figure 6.1: Self-Cleaning Process - This image depicts the internal self-cleaning mechanism of the indoor unit, which involves condensation, frosting, defrosting, and sterilization at 57°C to ensure clean air.

The unit features a 57°C high-temperature self-cleaning and sterilization function. Activate this mode via the remote control to ensure fresh and clean air by removing dust and bacteria from the evaporator.

6.3 Urtaroen mantentze-lanak

  • Before long periods of inactivity, run the unit in fan-only mode for a few hours to dry the internal components.
  • Clean the outdoor unit's coils and fins to remove any debris that may obstruct airflow.
  • Inspect refrigerant lines for any signs of leakage or damage.

7. Arazoak

Bezeroarentzako arreta-zerbitzuarekin harremanetan jarri aurretik, kontsultatu honako arazo eta irtenbide ohikoenak.

ArazoaKausa posibleaIrtenbidea
Unitatea ez da piztenArgirik ez, etengailu magnetotermikoa jauzi egin du, urrutiko agintearen bateriak agortuta.Egiaztatu energia-iturria, berrezarri etengailua, ordezkatu urrutiko agintearen bateriak.
Hozte/berotze nahikoa ezDirty air filters, blocked outdoor unit, low refrigerant, incorrect mode setting.Clean filters, clear obstructions, check refrigerant levels (professional service), select correct mode.
Barruko unitatetik ur-ihesaClogged drain pipe, improper installation angle.Clear drain pipe, ensure proper slope of drain hose.
Ezohiko zarataLoose parts, fan obstruction, unit not level.Check for loose components, remove obstructions, ensure unit is level.
Wi-Fi konexio arazoakRouter issues, incorrect Wi-Fi password, app not updated.Restart router, verify Wi-Fi credentials, update app, ensure unit is within Wi-Fi range.

Irtenbide hauek saiatu ondoren arazoa konpontzen ez bada, jarri harremanetan zerbitzu-teknikari kualifikatu batekin.

8. Zehaztapenak

Key technical specifications for the GarveeHome 12000 BTU Inverter Split System Air Conditioner.

Product dimensions and technical specifications for the GarveeHome Mini Split AC, including model number, SEER2, cooling/heating/dehumidifying capacity, power supply, max input power, and max input current.

8.1 irudia: Produktuaren neurriak eta zehaztapenak - This image provides a visual overview of the indoor and outdoor unit dimensions, along with key technical data such as cooling capacity, SEER2 rating, and power requirements.

EzaugarriZehaztapena
MarkaGarvee
Modelo zenbakiaWY-l1ZuA6uYMZeQGuNAyxSwIQEaFgBej
Hozte Potentzia12000 BTU
Edukiera1 tona
SEER2 Balorazioa22
liburukiatage115 Volt
Wattage1450 watt
Zarata Maila30 Decibels (Indoor Unit)
Estaldura EremuaGehienez 750 mXNUMX. Ft.
Ezaugarri bereziakFast Cooling, Heating & Cooling Function, Inverter Compressor, Remote Controlled, Sleep Mode, Wi-Fi Enabled

Oharra: Neurriak gutxi gorabeherakoak dira eta apur bat alda daitezke.

OsagaiaNeurriak (W x D x H)
Barne Unitatea29.96" x 7.87" x 11.61"
Kanpoko Unitatea27.76" x 10.98" x 20.87"

9. Bermea eta Laguntza

For warranty information, please refer to the documentation included with your purchase or contact Garvee customer support. Protection plans may be available for extended coverage.

For technical assistance, troubleshooting beyond this manual, or service inquiries, please contact Garvee customer support through their official channels.

Erlazionatutako dokumentuak - 2026 NEW-12K-115V-22 SEER2-WIFI 2.0

Aurreview 14,000 BTU Portable AC - Product Information
Official product information for the 14,000 BTU Portable Air Conditioner, model QCFDI, distributed by Garvee. Includes support contact details.
Aurreview 12'x16' Pergola Instalazio Eskuliburua eta Piezen Zerrenda | Garvee
Garvee 12'x16' Pergola muntatzeko gida osoa, piezen zerrenda zehatza, hardwarearen zehaztapenak eta urratsez urratseko argibideak barne.
Aurreview Garvee Portable Air Conditioner CF14 User Manual
This user manual provides comprehensive instructions for the Garvee Portable Air Conditioner CF14, including safety precautions, features, installation, operation, maintenance, and troubleshooting guidance.
Aurreview Garvee Window Air Conditioner Model NCA-06C/X1E-W & NCA-08C/X1E-W User Manual and Installation Guide
Comprehensive user manual and installation guide for the Garvee Window Air Conditioner, models NCA-06C/X1E-W and NCA-08C/X1E-W. Includes safety instructions, parts identification, installation steps, operation, maintenance, and troubleshooting.
Aurreview Garvee Chest Assembly Manual (Product ID: QCDCR)
Comprehensive assembly instructions and maintenance guide for the Garvee chest, product ID QCDCR.
Aurreview GARVEE PHO_33F4UXTD Bookshelf Assembly Instructions
Comprehensive assembly instructions for the GARVEE PHO_33F4UXTD bookshelf, including a detailed parts list, hardware list, and step-by-step visual guides translated into text.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.