1. Sarrera

The DATOUBOSS DN-022 Pure Sine Wave Inverter is a versatile power conversion device designed to transform DC (Direct Current) power from a 12V source into AC (Alternating Current) 220V power. Utilizing advanced MCU microprocessor-controlled SPWM technology, it delivers a pure sine wave output, ensuring compatibility with a wide range of electronic devices and appliances. This inverter is ideal for various applications, including portable solar power systems, automotive use, camping, and providing backup power for home or office electronics.

DATOUBOSS DN-022 Pure Sine Wave Inverter 1000W and 1500W models
Figure 1: DATOUBOSS DN-022 Pure Sine Wave Inverter (1000W and 1500W models)

2. Produktuaren ezaugarriak

  • Uhin sinusoidal hutsaren irteera: Employs MCU microprocessor-controlled SPWM technology for a pure sine wave output, ensuring clean power that is safe for sensitive electronics and appliances, preventing interference.
  • Dynamic Current Loop Control: Unique dynamic current loop control technology guarantees reliable and stable operation of the inverter.
  • Strong Load Adaptability: Capable of handling various load types, including inductive loads (e.g., refrigerators, freezers, induction cookers), capacitive loads, resistive loads, and mixed loads.
  • Babes Funtzio Integralak: Features multiple safety mechanisms including input over-voltage, bolumen azpikoatage, overload, overheat, and output short circuit protection.
  • LCD kristal likidoen pantaila: An ultra-clear LCD provides real-time monitoring of the inverter's working status, displaying internal temperature, input/output voltage, protection symbols, battery capacity, working status, output power, and frequency.
  • Bihurketa-eraginkortasun handia: Achieves a high conversion efficiency of up to 90-95%, minimizing power loss and extending battery life.
  • Buzzer Reminder: An audible buzzer alerts users immediately when a protection mechanism is triggered, indicating the inverter has entered protection mode and shut off power to the load.
  • Multiple Output Interfaces: Equipped with two European plugs for simultaneous use of two electrical appliances, a TYPE-C interface, a USB QC3.0 interface, and two USB 2.1A interfaces for diverse charging needs.
  • Urruneko kontrol erosoa: Includes a remote controller with Bluetooth connectivity, allowing for convenient inverter operation without manual intervention.

3. Segurtasun-informazioa eta neurriak

Mesedez, irakurri eta ulertu segurtasun-jarraibide guztiak inbertsorea instalatu edo erabili aurretik. Argibide hauek ez jarraitzeak deskarga elektrikoak, suteak edo lesio larriak eragin ditzake.

  • Instalazio profesionala: Installation and commissioning of this equipment should only be carried out by qualified electrical maintenance personnel who are familiar with the unit's structure and operational hazards.
  • Ingurumen-baldintzak: Keep the inverter away from water. Avoid any liquids dripping onto or gradually entering the machine. Do not handle the inverter or its connections with wet hands.
  • Flammable Substances: Ensure the inverter is kept away from flammable substances or areas where flammable gases may accumulate.
  • Goi Boltage Abisua: Bolumen altuatage is present inside the inverter. Do not attempt to open or service the machine yourself.
  • Itzali erabiltzen ez denean: Always switch off the inverter when it is not in use to prevent accidental operation or power drain.
  • Correct Input Connection: Never connect the inverter's input in reverse polarity or connect it directly to grid-connected power. Incorrect connections will lead to fuse blowing and can cause permanent damage to the inverter's circuit board.
Inverter with icons for various protections
Figure 2: Multilayer Safety Protection Features

4. Konfigurazioa eta instalazioa

4.1 Ingurumen baldintzak

  • Ingurumena: The installation environment must be dry, clean, and well-ventilated.
  • Lan-tenperatura: The inverter is designed to operate within a temperature range of -20°C to 80°C.

4.2 Konexio-argibideak

  1. Bateria konexioa: Ensure the inverter is securely connected to your 12V DC power source (e.g., battery) with correct polarity. Connect the red cable to the positive (+) terminal of the inverter and the battery, and the black cable to the negative (-) terminal of the inverter and the battery.
  2. Kableatzea: Always use the original connecting cables provided with the inverter to ensure optimal performance and safety.
  3. Aireztapena: Do not cover the inverter. Ensure there is adequate space around the unit for proper airflow and heat dissipation.
Video 1: Inverter connection and internal workings demonstration. This video illustrates the connection of the inverter to a battery and highlights key internal components and heat dissipation mechanisms.
Solar Conversion Wiring Diagram showing inverter connected to solar panels, battery, and various appliances
Figure 3: Solar Conversion Wiring Diagram. This diagram shows how the inverter integrates into a solar power system, connecting solar panels, a controller, a battery, and various household appliances.
Front and back panel of the inverter with labels for switch, USB, AC socket, LCD display, DC terminals, and fan
Figure 4: Inverter Front and Back Panel Layout. This image labels the key connection points and controls on the inverter, including the power switch, USB ports, AC socket, LCD display, DC positive and negative terminals, and the cooling fan.

5. Funtzionamendu-argibideak

5.1 Piztu/Itzaltzea

  1. Konektatu energia iturrira: Ensure the inverter is securely connected to your 12V DC power source (e.g., battery) with correct polarity.
  2. Aktibatu: Locate the power switch on the inverter (refer to Figure 4) and switch it to the "ON" position. The LCD display will illuminate, showing the current ambient temperature as part of the power-on sequence.
  3. Konektatu etxetresna elektrikoak: Plug your AC appliances into the European sockets or use the USB ports for charging. Ensure the total power consumption of connected devices does not exceed the inverter's rated continuous power.
  4. Itzali: Before disconnecting any appliances or the inverter from its power source, switch the power button to the "OFF" position.

5.2 Pantaila-argibideak

The LCD liquid crystal display provides crucial information about the inverter's status:

  • Power-on Display: Upon startup, the display shows the current ambient temperature.
  • Behe-boltage Babesa: Sarrera bolumena badatage drops below the applicable range (e.g., 10V for a 12V system), the inverter will trigger low-voltage protection and stop output. The display will show "9.9V 1500W" (example for 1500W model).
  • Goi-boltage Babesa: Sarrera bolumena badatage exceeds the applicable range (e.g., 15V for a 12V system), high-voltage protection will be triggered. The display will show "15.2V 1500W" (example for 1500W model).
  • Tenperatura altuko babesa: If the inverter's internal temperature becomes too high, it will enter high temperature protection, and the display will show "12.2V 1500W" (example for 1500W model) along with a temperature icon. The inverter will not operate normally under these conditions.
  • Zirkuitu laburren babesa: In case of a fault in the electrical appliance or load circuit, short-circuit protection will activate. The display will show "AC -SC" and "0W".
  • Gainkarga babesa: If the connected load power exceeds the inverter's rated value, overload protection will be triggered. The display will show "AC 220V 1600W" (example for 1500W model with 1600W load).
Detailed LCD display examples for different statuses including battery, voltage, and protection warnings
Figure 5: LCD Display Instructions. This image provides visual examples of the inverter's LCD display under various operating conditions and protection states.

6. Mantentzea

  • Mantendu garbi eta lehor: Regularly clean the exterior of the inverter with a dry cloth. Ensure no dust or debris accumulates in the ventilation openings.
  • Ziurtatu aireztapena: Periodically check that the inverter's cooling fans and air ducts are unobstructed to maintain optimal heat dissipation.
  • Konexioaren egiaztapenak: Inspect all electrical connections (battery terminals, output sockets) for tightness and corrosion. Loose connections can lead to power loss or overheating.
  • Biltegiratzea: If storing the inverter for an extended period, ensure it is kept in a dry, cool, and well-ventilated area, disconnected from any power source.
Inverter with smart fan, mute, power saving, temperature control icons
Figure 6: Smart Cooling Features. This image highlights the inverter's smart fan and temperature control, which are crucial for efficient heat dissipation and longevity.
Airflow diagram for 1000W inverter model
Figure 7: Airflow Diagram. This diagram illustrates the centralized dual air duct design for even heat dissipation, reducing MOS tube temperature and improving conversion efficiency.

7. Arazoak

If the inverter is not functioning correctly, refer to the LCD display for error messages and consult the following table:

Problem Indication (LCD / Buzzer)Kausa posibleaIrtenbidea
"9.9V 1500W" (Low Voltage)Bateria boltage baxuegia da.Recharge or replace the battery. Ensure the battery is fully charged before use.
"15.2V 1500W" (High Voltage)Bateria boltage altuegia da.Check the charging system or battery condition. Disconnect the inverter immediately if voltage ezegonkorra da.
Temperature icon / "12.2V 1500W" (High Temperature)Inverter is overheating due to poor ventilation or excessive load.Ensure adequate ventilation around the inverter. Reduce the connected load. Allow the inverter to cool down.
"AC -SC" (Short Circuit)Short circuit in the connected appliance or wiring.Disconnect all loads. Check appliances and wiring for faults. Reconnect one by one to identify the faulty device.
"AC 220V 1600W" (Overload)Total power consumption of connected devices exceeds inverter's capacity.Reduce the number or power of connected appliances. Ensure total load is within the inverter's continuous power rating.
No display / No power outputNo input power, loose connections, or internal fault.Check battery connections and charge level. Ensure power switch is ON. If problem persists, contact support.

8. Zehaztapenak

EzaugarriDN-022 (1000W Model)DN-023 (1500W Model)
Produktu EreduaDN-022DN-023
Irteerako potentzia (jarraitua)1000W1500W
Bistaratzeko metodoaLCD kristal likidoen pantaila
Sarrera boltage12V/24V
Sarrera boltage Barrutia12 V (10-15 V)24 V (20-30 V)
Vol. Baxuatage Babesa10V
Overboltage Babesa15V
Kargarik Gabeko Korrontea0.7A0.8A
Irteera boltage230V
Irteerako maiztasuna50Hz/60Hz
Irteerako uhin formaSine Wave Pure
Gainberotzearen babesa80°C ± 5°C
Bihurketa-eraginkortasuna≥%90
Hozteko metodoaBuilt-in Air-Cooled Fan
Dimentsio orokorra31*12*6.4cm (12.1*4.7*2.5 inches)
Produktuaren pisua1.9kg2.3kg
Produktuaren neurriak eta kableen luzerak
Figure 8: Product Dimensions and Cable Lengths.

9. Erabiltzaileentzako aholkuak

  • Monitorea pantaila: The inverter features a clear LCD display. Regularly check it for real-time status updates on voltage, power, and any active protection warnings. This helps in proactive troubleshooting.
  • Potentzia polifazetikoa: With multiple output options including European AC sockets, USB QC3.0, and standard USB 2.1A ports, this inverter can power a wide array of devices simultaneously. Plan your connections to stay within the continuous power limit.
  • Urruneko erosotasuna: Utilize the Bluetooth remote control feature for easy power management, especially when the inverter is installed in a less accessible location.

10. Bermea eta Laguntza

For any technical assistance, warranty claims, or support inquiries, please contact the manufacturer or seller directly using the information below:

  • Mobile/WeChat/Whatsapp/LINE: +8613783531376
  • Posta elektronikoa: Manager@xdatou.com

Gorde erosketaren egiaztagiria bermearen ondorioetarako.


Erlazionatutako dokumentuak - DN-022

Aurreview DATOU BOSS Uhin Sinusoidal Puruko Inbertsorearen Argibide Eskuliburua (1000W/1500W)
DATOU BOSS uhin sinusoidal puruko inbertsoreen (DN-022 eta DN-023 modeloak) argibideen eskuliburua, produktuaren ezaugarriak, pantailako adierazleak, zehaztapenak, instalazio-eskakizunak eta 1000W eta 1500W unitateen segurtasun-neurriak zehaztuz.
Aurreview Pure Sine Wave Inverter Manual - DATOUBOSS 1000W-3000W
Comprehensive manual for DATOUBOSS pure sine wave inverters (1000W-3000W), covering specifications, installation, troubleshooting, and operating modes for models DN2000W12V through DN2000W60V.
Aurreview DATOUBOSS Pure Sine Wave Inverter Manual - DN-Series
Comprehensive user manual for DATOUBOSS DN-Series pure sine wave inverters (1000W-3000W). Includes detailed specifications, installation guidelines, operational modes, protection features, and troubleshooting solutions for models DN2000W12V through DN2000W60V.
Aurreview Uhin Sinusoidal Puruko Inbertsorearen Eskuliburua - DATOUBOSS Zehaztapenak eta Gida
DATOUBOSS uhin sinusoidal puruko inbertsorearen eskuliburu osoa, zehaztapenak, babes-funtzioak, pantaila-egoerak, urrutiko agintearen funtzionamendua eta instalazio-jarraibideak zehaztuz.
Aurreview Nedis Power Inverter (1000/2000 Watt) Pure Sine Wave Quick Start Guide
This document provides a quick start guide for the Nedis Power Inverter (1000/2000 Watt) Pure Sine Wave. It covers intended use, safety instructions, mounting, connecting the inverter and remote control, powering devices via AC socket or USB, and troubleshooting. Models covered include PIP100012EBK, PIP100012FBK, PIP100024EBK, PIP100024FBK, PIP200012EBK, PIP200012FBK, PIP200024EBK, and PIP200024FBK.
Aurreview DATOU BOSS Pure Sine Wave Inverter DN-022 - 1000W/1200W/1500W Instruction Manual
Instruction manual for the DATOU BOSS Pure Sine Wave Inverter (DN-022). This document details product features, technical specifications for 1000W, 1200W, and 1500W models, and installation requirements. It highlights the inverter's MCU microprocessor-controlled SPWM technology, pure sine wave output, dynamic current control, and comprehensive protection functions, along with its LCD display for status monitoring.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.