1. Sarrera
The AT1-4000X Variable Frequency Drive (VFD) is designed to provide precise speed control for 3-phase 4kW AC motors, operating from a single-phase 220V AC input. This VFD utilizes a unique control method to achieve high torque, high accuracy, and a wide speed regulating range, ensuring high performance in various applications.
Ezaugarri nagusiak hauek dira:
- Excellent anti-trip performance and adaptability to challenging power conditions, temperature fluctuations, humidity, and dust interference, significantly enhancing stability.
- Optimized PWM control technology and electromagnetic compatibility for low noise and reduced electromagnetic interference.
- User-friendly design for easy operation and wiring.
- Fast start and stop response with substantial torque at low speeds.
2. Segurtasun-neurriak
Failure to follow these instructions may result in death, serious injury, or significant property loss.
- Always ensure the power supply is disconnected before performing any wiring or maintenance.
- Never connect the U/V/W output terminals to the AC power supply. Doing so will cause severe damage to the inverter.
- Do not install the inverter in environments with flammable or explosive gases, as this poses a risk of explosion.
- The ground terminal (GND) of the inverter must be properly and securely grounded.
- Only qualified professionals should perform internal wiring or open the inverter's casing due to the presence of high voltage.

3. Produktua amaitu daview
The AT1-4000X VFD features a clear digital display and an intuitive control panel for easy monitoring and adjustment of motor parameters. The unit is designed for efficient heat dissipation with integrated cooling fins and fans.
3.1 Kontrol-panela
Aurrealdeko panelak honako hauek ditu:
- Bistaratze digitala: Shows operational parameters such as frequency (Hz), forward/reverse status (FWD/REV), and revolutions per minute (r/min).
- Adierazleak: Power, Hz, FWD, REV, r/min.
- Botoiak:
DISP: Display mode selection.PROG: Program mode entry/exit.FUNC/DATA: Function/Data entry.FWD/REV: Forward/Reverse direction control.▲(Up Arrow): Increase value or navigate menus.▼(Down Arrow): Decrease value or navigate menus.RUN: Start motor operation.STOP/RESET: Stop motor operation or reset errors.
- Botoi birakaria: For fine adjustment of frequency or parameter values.
3.2 Terminalak
The VFD is equipped with clearly labeled terminals for power input and motor output.

4. Zehaztapenak
| Ezaugarri | Zehaztapena |
|---|---|
| Eredua | AT1-4000X |
| Balorazio baloratuatage (sarrera) | AC 220V (Single Phase) |
| Suitable Motor Power | 4 kW |
| Kontrol-metodoa | V/F Open Loop |
| Irteera boltage Adjustable Method | PWM Kontrola |
| Irteera-korronte nominala | 20A |
| Maximum Output Frequency Range | 0 - 400Hz |
| Mota | Inverter Motor Drive |
| Jatorria | Txina kontinentala |
| Paketearen neurriak (L x W x H) | 23 cm x 23 cm x 16 cm |
| Paketearen pisua | 1.498 kg |
5. Konfigurazioa
Before proceeding with installation and wiring, ensure all safety precautions are understood and followed. Installation should be performed by qualified personnel.
5.1 Instalazio-ingurunea
- Install the VFD in a clean, dry, and well-ventilated area.
- Avoid direct sunlight, high temperatures, excessive humidity, and dusty environments.
- Ensure there is sufficient space around the unit for proper heat dissipation.
- Ez instalatu material sukoi edo lehergarrien ondoan.
5.2 Kableatzeko jarraibideak
The VFD is designed for simple wiring. Always ensure the power supply is OFF before connecting any wires. Connect wires after removing the terminal screws.

| Terminala | Funtzioa | Deskribapena |
|---|---|---|
| L, N | 220V AC sarrera | Connect to single-phase AC 220V power supply. |
| U, V, W | 3-Phase AC Motor Output | Connect to the three-phase AC motor terminals. |
| GND | Lurra | Konektatu lurrerako konexio fidagarri batera. |
6. Funtzionamendu-argibideak
Once the VFD is correctly installed and wired, you can begin operation. Familiarize yourself with the control panel functions.
6.1 Oinarrizko funtzionamendua
- Piztu: Ensure all connections are secure, then apply single-phase 220V AC power to the L and N terminals. The VFD display should illuminate.
- Abiarazi motorra: Sakatu
RUNbutton to start the motor. The FWD or REV indicator will light up depending on the current direction setting. - Maiztasuna/Abiadura doitu: Use the rotary knob to adjust the output frequency, which in turn controls the motor speed. The display will show the current frequency (Hz) or RPM (r/min).
- Norabidea aldatu: Sakatu
FWD/REVbutton to toggle the motor's rotation direction. - Motorra gelditu: Sakatu
STOP/RESETbotoia motorra gelditzeko.
6.2 Parameter Programming
The PROG eta FUNC/DATA buttons, along with the arrow keys (▲, ▼), are used to access and modify various operating parameters. Refer to the detailed programming manual (if available) for specific parameter settings relevant to your application.
- Sakatu
PROGto enter or exit programming mode. - Erabili
▲eta▼to navigate through parameter groups or individual parameters. - Sakatu
FUNC/DATAto select a parameter for editing or to confirm a value. - Use the rotary knob or arrow keys to change the parameter value.
- Sakatu
FUNC/DATAberriro balio berria gordetzeko.
7. Mantentzea
Regular maintenance helps ensure the longevity and reliable operation of your VFD.
- Garbiketa: Mantendu VFD-a garbi eta hautsik eta hondakinik gabe. Erabili zapi leun eta lehor bat garbitzeko. Ez erabili garbitzaile likidorik.
- Aireztapena: Ensure that the cooling fans and ventilation openings are not obstructed to prevent overheating.
- Ikuskapena: Aldian-aldian egiaztatu kableatu-konexio guztiak estutasuna eta higadura edo kalteen zantzurik dagoen egiaztatzeko.
- Zerbitzu profesionala: Due to high internal voltages, any internal inspection or repair should only be performed by qualified service personnel. Do not attempt to open the VFD casinzeure burua.
8. Arazoak
Atal honek arazo arruntetarako jarraibide orokorrak eskaintzen ditu. Arazo konplexuetarako, jarri harremanetan laguntza teknikoarekin.
| Arazoa | Kausa posiblea | Irtenbidea |
|---|---|---|
| VFD does not power on | No input power; Incorrect wiring | Check power supply and input wiring (L, N). |
| Motorrak ez du martxan | Motor wiring incorrect; VFD in STOP mode; Parameter error | Verify motor wiring (U, V, W); Press RUN; Check programmed parameters. |
| Motor abiadura ezegonkorra | Incorrect V/F settings; Motor load fluctuations | Adjust V/F curve parameters; Ensure motor is suitable for load. |
| Gainkargaren errorea | Motor overloaded; Incorrect overload protection setting | Reduce motor load; Check and adjust overload protection parameters. |
If an error occurs, the VFD display may show an error code. Press the STOP/RESET button to clear the error after addressing the cause.
9. Erabiltzaileentzako aholkuak
- For optimal performance, ensure the VFD is matched correctly to your motor's power rating (e.g., 4kW motor for this 4kW VFD).
- When adjusting frequency, make gradual changes to avoid sudden motor stress.
- Always ensure proper grounding to prevent electrical hazards and ensure stable operation.
- Keep the VFD's ventilation clear to prevent overheating, especially during continuous operation.
10. Bermea eta Laguntza
For warranty information, technical support, or service inquiries, please refer to the documentation provided at the point of purchase or contact the seller directly. Keep your purchase records handy when seeking support.