Leviton 2610

Leviton 2610 30 Amp 125V Flush Mount Locking Receptacle User Manual

1. Sarrera

The Leviton 2610 is an industrial-grade flush mounting locking receptacle designed for reliable electrical connections. This 30 Amp, 125 Volt device ensures secure power delivery in demanding environments, preventing accidental disconnection of power cords. It is built with high-quality materials to provide superior performance and dependability.

Leviton 2610 30 Amp 125V Flush Mount Locking Receptacle

1.1. irudia: Aurrealdea view of the Leviton 2610 30 Amp 125V Flush Mount Locking Receptacle.

2. Segurtasun informazioa

OHARRA: Risk of electric shock. Improper installation or use can result in serious injury or death. Always follow these safety guidelines:

3. Produktuaren ezaugarriak

4. Zehaztapenak

Modelo zenbakia2610
MarkaLeviton
Balorazio elektrikoa30 Amp, 125 Volt
Konfigurazioa3-Wire, Grounding
Muntatze MotaFlush mendia
KoloreaBeltza
MaterialaSolidoa
Produktuaren neurriak1.3 cm-ko luzera x 3.5 cm-ko zabalera
Elementuaren pisua3.68 ontza
FabrikatzaileaLEVITON MFG CO INC

5. Konfigurazioa eta instalazioa

Installation of this electrical device should only be performed by a qualified electrician. Adherence to all national and local electrical codes is mandatory.

  1. Deskonektatu energia: Before beginning any work, ensure the power supply to the circuit is completely disconnected at the main circuit breaker or fuse box. Use a voltage tester to confirm the circuit is de-energized.
  2. Prestatu kableatua: Strip insulation from the circuit wires (hot, neutral, ground) to the appropriate length as specified by the receptacle's terminals. Ensure only copper conductors are used.
  3. Konektatu kableak: Connect the wires to the corresponding terminals on the Leviton 2610 receptacle. Typically, the hot wire connects to the brass terminal, the neutral wire to the silver terminal, and the ground wire to the green terminal. Tighten all terminal screws securely.
  4. Muntaiaren hartunea: Carefully fold the wires into the electrical box and secure the receptacle to the box using the provided mounting screws. Ensure the receptacle is flush with the wall surface.
  5. Estalki-plaka instalatu: Attach a compatible cover plate (sold separately) over the installed receptacle.
  6. Berrezarri boterea: Once installation is complete and all connections are secure, restore power at the circuit breaker and test the receptacle for proper operation.

6. Funtzionamendu-argibideak

To use the Leviton 2610 locking receptacle:

  1. Txertatu entxufea: Align the blades of the compatible locking plug with the corresponding slots on the receptacle.
  2. Lock Plug: Insert the plug fully into the receptacle. Once inserted, twist the plug clockwise until it locks securely into place. This locking action prevents accidental disconnections.
  3. Kendu entxufea: To disconnect, twist the plug counter-clockwise to unlock it, then pull the plug straight out from the receptacle.

7. Mantentzea

Regular inspection and basic maintenance can help ensure the longevity and safe operation of your Leviton 2610 receptacle:

8. Arazoak

If you encounter issues with your Leviton 2610 receptacle, consider the following:

9. Bermea eta Laguntza

For detailed warranty information, technical support, or to find authorized service centers, please visit the official Leviton website or contact Leviton customer service directly. Keep your purchase receipt as proof of purchase for any warranty claims.

Erlazionatutako dokumentuak - 2610

Aurreview Leviton GFCI Receptacle Installation and Testing Guide
A comprehensive guide on how to install and test a Leviton SmartLock Pro GFCI Receptacle, including wiring instructions, safety precautions, and troubleshooting tips.
Aurreview Leviton GFCI entxufea USB atakekin instalazio eta erabilera eskuliburua
Leviton GFCI entxufeak USB atakekin instalatzeko eta erabiltzeko gida osoa, kableatu argibideak, segurtasun abisuak, probak egiteko prozedurak eta bermearen informazioa barne.
Aurreview Installing and Testing Leviton Smart GFCI Outlet: A Comprehensive Guide
Step-by-step instructions for installing and testing Leviton Smart GFCI outlets (models D2GF1, D2GF2). Learn about GFCI functionality, wiring, troubleshooting, and safety precautions.
Aurreview Leviton SmartlockPro GFCI Receptacle Installation and Testing Guide
Comprehensive guide to installing and testing Leviton SmartlockPro Ground Fault Circuit Interrupter (GFCI) receptacles. Covers safety precautions, wiring, troubleshooting, and product features.
Aurreview Leviton Commercial & Industrial Grade Switches Selection Guide
A comprehensive selection guide from Leviton detailing commercial and industrial grade switches, including toggle, Decora Plus, Lev-lok, antimicrobial, and specialty switch types with application details and wiring diagrams.
Aurreview Leviton EV40P EV Seriea 40 AMP Entxufagarriaren kargagailuaren instalazio eskuliburua
Leviton EV40P EV Serieko 40 ibilgailuaren instalazio eskuliburua AMP Plug-In Electric Vehicle Charger. Includes safety warnings, specifications, installation steps, operating procedures, RFID card usage, error messages, maintenance, and warranty information.