This manual provides essential information for the safe and proper use of your Westinghouse 70641 10-Feet Fixture Ground Wire. Please read these instructions carefully before installation and retain for future reference. This product is designed to provide a reliable grounding path for electrical fixtures and fans.
2. Segurtasun informazioa
Always prioritize safety when working with electrical components. Failure to follow these guidelines may result in electrical shock, fire, or personal injury.
- Deskonektatu energia: Always turn off power at the circuit breaker or fuse box before installing or servicing any electrical fixture.
- Pertsonal kualifikatua: Instalazio prozesuaren edozein atalen inguruan ziur ez bazaude, kontsultatu elektrizista kualifikatu bati.
- Aplikazio egokia: Ensure the wire gauge (18 AWG) is appropriate for your specific application and local electrical codes.
- Ikuskatu kalteak ikusteko: Before installation, inspect the wire for any signs of damage. Do not use damaged wire.
- Konexio seguruak: Ensure all electrical connections are tight and secure to prevent arcing or overheating.
3. Produktua amaitu daview
The Westinghouse 70641 is a 10-foot bare copper ground wire, specifically designed for establishing a safe grounding connection in light fixtures and ceiling fans. It features an 18-gauge construction and is rated for temperatures up to 105 degrees Celsius.

A coiled length of bare copper wire, approximately 10 feet long, used for electrical grounding applications. One end may feature a pre-attached eyelet for easier connection.
4. Instalatzeko jarraibideak
This ground wire is intended to connect the metal housing of a light fixture or fan to the electrical system's ground. Follow these general steps for installation:
- Lan-eremua prestatu: Ensure power to the fixture's circuit is completely off at the main electrical panel. Use a voltage tester to confirm no power is present.
- Access Fixture Wiring: Carefully remove the fixture canopy or cover to expose the wiring connections.
- Connect to Fixture: Attach one end of the Westinghouse 70641 ground wire to the metal housing or designated ground screw of the light fixture or fan. If the wire comes with a pre-attached eyelet, use it for a secure screw connection. If not, strip a small amount of insulation (if present, though this is bare wire) and wrap the bare copper wire clockwise around the ground screw, tightening firmly.
- Connect to Electrical Box: Connect the other end of the Westinghouse 70641 ground wire to the ground wire from the electrical supply (typically a bare copper or green insulated wire) using an appropriate wire connector (e.g., a wire nut). Ensure the connection is secure. Alternatively, if the electrical box has a designated ground screw, connect the wire directly to it.
- Kableatu segurua: Carefully tuck all wires back into the electrical box, ensuring no wires are pinched or exposed.
- Berrezarri boterea: Replace the fixture canopy or cover. Restore power at the circuit breaker and test the fixture's operation.
Always consult local electrical codes and manufacturer instructions for the specific fixture you are installing.
5. Funtzionamendua
Once properly installed, the Westinghouse 70641 ground wire operates passively as a critical safety component. It provides a low-resistance path for fault current to flow safely to the earth in the event of an electrical malfunction, such as a short circuit. This action helps to trip the circuit breaker or blow a fuse, preventing electrical shock and reducing the risk of fire.
6. Mantentzea
The Westinghouse 70641 Fixture Ground Wire is a passive electrical component and requires no routine maintenance. However, it is recommended to periodically inspect visible electrical connections for any signs of corrosion, looseness, or damage. If any issues are found, ensure power is disconnected before attempting any repairs or adjustments.
7. Arazoak
If you encounter issues related to grounding after installation, consider the following:
- Konexio solteak: Ensure all connections involving the ground wire are tight and secure. A loose connection can compromise the grounding path.
- Kableatu okerra: Double-check that the ground wire is correctly connected to both the fixture and the electrical box's ground system.
- Zirkuitu etengailuaren abiapuntua: If the circuit breaker trips immediately after restoring power, there may be a short circuit or an improper connection. Disconnect power and re-examine all wiring.
- Damaged Wire: Inspect the ground wire for any nicks, cuts, or corrosion that could impede its function. Replace if damaged.
For persistent electrical issues, consult a qualified electrician.
8. Zehaztapenak
| Ezaugarri | Xehetasuna |
|---|---|
| Marka | Westinghouse |
| Modelo zenbakia | 70641 |
| Materiala | Kobrea |
| Luzera | 10 oin (gutxi gorabehera 3.05 metro) |
| Kable neurgailua | 18 AWG (American Wire Gauge) |
| Tenperaturaren balorazioa | 105 °C (221 °F) |
| liburukiatage Balorazioa | 120 Volts (typical application) |
| Elementuaren pisua | 0.4 ontza |
| Produktuaren neurriak | 120 x 3.5 x 0.75 inches (uncoiled length x width x height of coil) |
| UPC | 030721706417 |
9. Bermea eta Laguntza
Bermea: This product is covered by the warranty as labelled on its packaging. Please refer to the product packaging for specific warranty terms and conditions.
Bezeroarentzako laguntza: For technical assistance, product inquiries, or warranty claims, please visit the official Westinghouse website or contact their customer service department. Contact information can typically be found on the product packaging or the Westinghouse brand webgunea.