ICM Controls ICM203 Atsedenaldiko Atzerapen Tenporizadorearen Argibide Eskuliburua

1. Sarrera

The ICM Controls ICM203 is a universal voltage delay on break timer designed to protect compressors from damage caused by rapid short cycling. This anti-short cycle relay ensures that the compressor remains off for a set period after power interruption, allowing system pressures to equalize before restarting. It operates across a wide voltage range and features an adjustable delay setting.

Aurrealdea view of the ICM Controls ICM203 Delay on Break Timer, showing the adjustable dial, wiring terminals, and product labeling.

Aurrealdea view of the ICM Controls ICM203 Delay on Break Timer, showing the adjustable dial, wiring terminals, and product labeling.

2. Ezaugarri nagusiak

  • Konpresorearen Babesa: Prevents damage from rapid short cycling with built-in lockout safety.
  • Atzerapen erregulagarria: Set custom delay time from 1.8 to 600 seconds for flexible system control.
  • Zabala Voltage Barrutia: Operates on 18–240 VAC, suitable for a broad range of HVAC and refrigeration applications.
  • Instalazio sinplea: Easy 2-wire hookup for quick and reliable setup.
  • Iraunkorra eta fidagarria: Solid-state design ensures long-lasting performance in demanding environments.

3. Zehaztapenak

ZehaztapenaBalioa
Modelo zenbakiaICM203
Sarrera boltage18-240 VAC
Atzerapen erregulagarria1.8–600 Seconds (0.03–10 Minutes)
Karga Korrontea1.5 Amp Max
Produktuaren neurriak5.08 cm x 5.08 cm x 3.18 cm (2" S x 2" Z x 1.25" A)
Elementuaren pisua1.6 ontza (45.36 gramo)
Ezarpen kopurua1 (adjustable dial)
FabrikatzaileaICM kontrolak
Aldea view of the ICM Controls ICM203 Delay on Break Timer, illustrating its depth and mounting hole.

Aldea view of the ICM Controls ICM203 Delay on Break Timer, illustrating its depth and mounting hole.

4. Instalazioa

Segurtasun abisua: Installation of this device involves working with electrical components and potentially high voltages. To prevent electric shock or damage to equipment, installation should only be performed by a qualified professional or person familiar with HVAC electrical systems. Always disconnect power to the unit before beginning installation.

Close-up of the ICM Controls ICM203 Delay on Break Timer being wired, showing the red jumper wire for 120/240 VAC selection.

Close-up of the ICM Controls ICM203 Delay on Break Timer being wired, showing the red jumper wire for 120/240 VAC selection.

Instalazio-urrats orokorrak:

  1. Deskonektatu energia: Ensure all power to the HVAC unit or compressor is completely disconnected at the circuit breaker.
  2. Locate Compressor Contactor: Identify the low voltage control circuit for the compressor contactor.
  3. Hari-konexioa: The ICM203 features a simple 2-wire hookup. Connect the two wires of the ICM203 in series with the 24 VAC control circuit that energizes the compressor contactor coil. This means the timer will interrupt the control voltage kontaktulariari.
  4. liburukiatagHautaketa (aplikagarria bada): The ICM203 is universal voltage. For 120/240 VAC applications, ensure the red jumper wire is correctly configured or cut as indicated on the device label, if necessary for your specific voltage. Refer to the device's printed instructions for precise wiring diagrams.
  5. Muntaketa: Securely mount the ICM203 in a suitable location within the control panel or near the compressor, ensuring it is protected from environmental elements.
  6. Berrezarri boterea: Once wiring is complete and verified, restore power to the unit.
Hands installing the ICM Controls ICM203 Delay on Break Timer into an HVAC unit, showing wiring connections.

Hands installing the ICM Controls ICM203 Delay on Break Timer into an HVAC unit, showing wiring connections.

Symbol of a lightning bolt with text 'Requires installation by a professional or qualified person'.

This device requires installation by a professional or qualified person due to electrical safety considerations.

5. Funtzionamendua

The ICM203 operates automatically once installed. Its primary function is to enforce a delay before the compressor can restart after a power interruption or a call for cooling is removed and then immediately reapplied. This delay protects the compressor from short cycling.

Atzerapen-denbora doitzea:

The delay time is adjustable using the red dial located on the front of the unit. The dial is marked in minutes, typically ranging from 0.03 minutes (approximately 1.8 seconds) to 10 minutes (600 seconds). To adjust the delay:

  1. Locate the Dial: Find the red adjustment dial on the face of the ICM203.
  2. Rotate to Desired Setting: Carefully rotate the dial using a small screwdriver or similar tool to align the indicator with the desired delay time in minutes. Common settings are often between 3 to 5 minutes to allow sufficient pressure equalization.
  3. Egiaztatu funtzionamendua: After setting, observe the system's behavior to ensure the delay functions as intended before the compressor restarts.

6. Mantentzea

The ICM Controls ICM203 Delay on Break Timer is a solid-state device designed for reliable, maintenance-free operation. No routine maintenance is required. Periodically, ensure that electrical connections remain secure and free from corrosion. If the unit appears damaged or is not functioning correctly, it should be inspected by a qualified technician.

7. Arazoak

If the ICM203 is not functioning as expected, consider the following:

  • No Delay: Verify the dial is set to a non-zero delay time. Ensure the unit is correctly wired in series with the compressor contactor's control circuit.
  • Konpresorea ez da martxan jartzen: Check for proper power supply to the ICM203. Ensure all wiring connections are secure. If the delay period has elapsed and the compressor still does not start, investigate other components of the HVAC system.
  • Incorrect Delay Time: Re-adjust the dial to the desired setting. Note that the adjustment at the very low end of the scale can be sensitive.
  • Unit Damage: Visually inspect the ICM203 for any signs of physical damage or burning. If damaged, replace the unit.

For persistent issues, it is recommended to consult a qualified HVAC technician.

8. Bermearen informazioa

ICM Controls products are known for their quality and reliability. The ICM203 is manufactured in the USA and comes with a warranty designed to ensure customer satisfaction. For specific details regarding the warranty period and terms, please refer to the official ICM Controls webgunea edo jarri harremanetan laguntza teknikoarekin.

Seal indicating 'BEST WARRANTY IN THE INDUSTRY' and 'MADE IN AMERICA' with a US flag.

ICM Controls products are proudly Made in America and backed by a strong industry warranty.

9. Laguntza Teknikoa

For technical assistance, installation questions, or troubleshooting support, please contact ICM Controls Technical Support.

Text displaying 'Please call 1-800-365-5525 Opt. 8 Mon-Fri 8-5 EST for Technical Support'.

Contact ICM Controls Technical Support for assistance.

Telefonoa: 1-800-365-5525, Option 8

Ordutegia: Astelehenetik ostiralera, 8:00etatik 5:00etara (EST)

Erlazionatutako dokumentuak - ICM203

Aurreview ICM Controls Timers and Motor Protection Relays Catalog
Comprehensive catalog of ICM Controls timers, delay relays, motor protection modules, and voltage monitors, including delay on make, delay on break, random start, bypass timers, freeze protection, compressor protection, and phase loss/reversal protection devices. Features detailed specifications, applications, and replacement part information.
Aurreview ICM450A eta ICM450A PLUS+ 3 faseko linea programagarria Voltage Monitors Installation and Operation Guide
This guide provides detailed information on the installation, operation, and specifications of the ICM450A and ICM450A PLUS+ programmable 3-phase line voltage monitors. It covers features such as phase unbalance protection, over/under voltage protection, delay on break timer, and Modbus communication for the PLUS+ model. Troubleshooting tips and a one-year limited warranty are also included.
Aurreview ICM493 fase bakarreko voltage Monitor with Surge Protection Installation Guide
Detailed guide for installing, operating, and applying the ICM493 Programmable Single-Phase Voltage Monitor with Surge Protection. Covers safety, installation steps, calibration, specifications, and button functions for HVAC and industrial applications.
Aurreview ICM870 9A/16A Soft Start Installation and Operation Guide
Detailed installation, operation, and application guide for the ICM870 9A/16A soft start controller, including specifications, features, fault codes, and wiring diagram. Designed for HVAC, marine, and RV applications.
Aurreview ICM870-32A Soft Start Controller: Installation and Operation Guide
Comprehensive guide to the ICM870-32A soft start motor controller from ICM Controls. Learn about its features, specifications, installation, operation, and troubleshooting for HVAC, RV, and marine applications.
Aurreview ICM402 3 Faseko Monitorea: Ezaugarriak, Zehaztapenak eta Kableatua
ICM402 3 Faseko Monitoreari buruzko informazio zehatza, bere ezaugarriak, zehaztapen teknikoak eta kableatu-diagramak barne. Gailu honek fase-galera, fase-alderantzikapena eta fase-desoreka babesten ditu, konpresoreetarako aproposa.