Intermatic ET1725C

Intermatic ET1725C Electronic 7-Day SPST Timer Instruction Manual

Model: ET1725C

1. Sarrera

This manual provides detailed instructions for the installation, programming, and operation of your Intermatic ET1725C Electronic 7-Day SPST Timer. This device is designed to automate the control of electrical loads with precise, up-to-the-minute scheduling. It features battery backup for power loss, up to 14 ON/OFF set points per circuit, and automatic daylight saving time corrections.

The ET1725C is an upgrade from basic mechanical time switches, offering enhanced functionality and ease of use. Its contacts can be configured as two independently operated SPST, one simultaneously operated DPST, or independently pulsed SPST for contactor and bell ringing applications. It supports multi-volt operation from 120-277 VAC, 50/60 Hz.

2. Segurtasun informazioa

OHARRA: Risk of electrical shock. More than one disconnect switch may be required to de-energize the equipment before servicing. Always disconnect power at the circuit breaker or fuse box before installing or servicing this timer.

Use 10-18 gauge copper conductors rated for at least 75°C (167°F) for all connections.

DO NOT REMOVE THIS INSULATOR. This insulator is critical for safe operation.

Produktu honek Kaliforniako Estatuak minbizia eta jaiotzetiko akatsak edo bestelako ugalketa-kalteak eragiten dituztela ezagutzen dituen produktu kimikoak ditu (65. Proposamenaren abisua).

Intermatic ET1725C Electronic Timer with internal view showing wiring terminals and safety warnings.

2.1. irudia: Barnekoa view of the Intermatic ET1725C timer, highlighting wiring terminals and critical safety warnings printed on the device. This image shows the LCD display, control buttons, battery compartment, and the terminal block with labels for Timer Power, Line 1, Load 1, Line 2, and Load 2. A prominent yellow label warns about electrical shock and conductor requirements.

3. Instalazioa

3.1 Muntaketa

The Intermatic ET1725C timer is designed for enclosure mounting. Ensure the mounting location is suitable for electrical equipment and provides adequate ventilation.

Closed gray enclosure of the Intermatic ET1725C Electronic Timer.

3.1. irudia: The closed gray enclosure of the Intermatic ET1725C timer, showing its robust design suitable for various installation environments. The Intermatic logo is embossed on the front.

3.2 Kableatua

Before wiring, ensure all power to the circuit is disconnected at the main service panel. Refer to the wiring diagrams below for proper connection based on your specific application. The ET1725C supports various configurations including SPST and DPST.

Wiring diagrams for Intermatic ET1700 series timers, showing various configurations for SPST, DPST, and pulsed applications.

3.2. irudia: Comprehensive wiring diagrams for the Intermatic ET1700 series, including configurations for ET1705-120 VAC-SPST, ET1715-SPDT (load switching), ET1725-240 VAC-DPST, ET1725-2x SPST, ET1725-2x SPST (bell ringing), and ET1725-Pulse 2x SPST (bell ringing). These diagrams illustrate connections for Timer Power, Line, Neutral, and Load terminals.

4. Setup & Programming

The ET1725C allows for flexible programming with up to 14 ON/OFF set points per circuit. The timer automatically adjusts for daylight saving time.

Intermatic ET1725C Electronic Timer with the instruction sheet visible, showing the display and control buttons.

4.1. irudia: The Intermatic ET1725C timer with its front panel open, revealing the LCD display, programming buttons (MODE, DAY, RESET, ENTER NEXT, ON/OFF), and the battery compartment. An instruction sheet is partially visible, indicating the comprehensive nature of the product's documentation.

4.1 Hasierako konfigurazioa

  1. Piztu: After installation and power connection, the display should illuminate.
  2. Ezarri uneko ordua:
    • Sakatu MODUA button until "SET TIME" appears.
    • Erabili UP eta BEHERA geziak ordua eta minutua doitzeko.
    • Sakatu ENTER NEXT baieztatzeko.
  3. Ezarri uneko eguna:
    • Sakatu EGUNA button to cycle through the days of the week until the current day is displayed.
  4. Udako ordua (DST): The timer automatically corrects for DST. Ensure the correct year is set if prompted during initial setup.

4.2 Programming ON/OFF Events

The timer allows for up to 14 ON/OFF set points per circuit. Each set point can be assigned to specific days of the week.

  1. Sakatu MODUA button until "PROGRAM" appears.
  2. The display will show "ON 1". Use the UP eta BEHERA arrows to set the desired ON time for the first event.
  3. Sakatu ENTER NEXT.
  4. The display will show "OFF 1". Use the UP eta BEHERA arrows to set the desired OFF time for the first event.
  5. Sakatu ENTER NEXT.
  6. The display will show the days of the week. Use the EGUNA button to select the days for this program. You can select individual days, weekdays, weekends, or all days.
  7. Sakatu ENTER NEXT programa gordetzeko.
  8. Repeat steps 2-7 for additional ON/OFF events (ON 2, OFF 2, etc.).
  9. Programazio modutik irteteko, sakatu MODUA button until the current time is displayed.

4.3 Eskuz gainidaztea

The timer can be manually overridden using the ON/OFF buttons. Pressing these buttons will toggle the load's state (ON or OFF) without affecting the programmed schedule. The timer will revert to the schedule at the next programmed event.

5. Funtzionamendua

Once programmed, the Intermatic ET1725C will operate automatically according to your set schedule. The LCD display shows the current time, day, and the status of Load 1 and Load 2 (ON/OFF).

6. Mantentzea

6.1 Bateria ordezkatzea

The ET1725C uses a replaceable battery for backup power. If the display becomes dim or the timer loses settings during a power outage, the battery may need replacement.

  1. OHARRA: Disconnect all power to the timer at the circuit breaker before opening the unit.
  2. Open the timer enclosure.
  3. Kokatu bateriaren konpartimendua.
  4. Carefully remove the old battery and replace it with a new, equivalent battery (e.g., standard AAA non-rechargeable alkaline battery).
  5. Close the battery compartment and the timer enclosure.
  6. Restore power and verify the timer's functionality.

6.2 Garbiketa

Clean the exterior of the timer with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no moisture enters the unit.

7. Arazoak

ArazoaKausa posibleaIrtenbidea
Tenporizadorearen pantaila hutsik dago.No power to the unit or dead backup battery.Check circuit breaker. Ensure proper wiring. Replace backup battery.
Load does not turn ON/OFF at programmed times.Incorrect programming, manual override active, or wiring issue.Review programming steps. Check if manual override is active. Verify wiring connections.
Time or settings are lost after power outage.Backup battery is weak or dead.Ordeztu ordezko bateria.
Pantaila irakurtzeko zaila da.Poor lighting conditions or small LCD.Ensure adequate lighting. This is a known characteristic of some LCDs.

8. Zehaztapenak

9. Bermea eta laguntza

9.1 Bermearen informazioa

The Intermatic ET1725C Electronic Timer comes with a 1-year warranty. This warranty covers replacement of the unit due to manufacturing defects but does not cover labor costs associated with removal or reinstallation. Please retain your proof of purchase for warranty claims.

9.2 Bezeroarentzako laguntza

For technical assistance, troubleshooting, or warranty inquiries, please contact Intermatic customer support. Refer to the official Intermatic website or the included instruction guide for current contact information.

Visit Intermatic's Official Webgunea

Erlazionatutako dokumentuak - ET1725C

Aurreview Intermatic Electronic 7-Day Water Heater Time Switches EH10 EH40 User Manual
Comprehensive instruction manual for Intermatic EH10 and EH40 electronic 7-day water heater time switches. Covers installation, programming, specifications, safety, and warranty information.
Aurreview Intermatic Spring Wound Interval Timer Installation and Operation Guide
Detailed installation, operation, and application guide for Intermatic spring wound interval timers (FF and FD models). Includes switch ratings, wiring diagrams, and warranty information.
Aurreview Intermatic EI200 Electronic In-Wall Countdown Timer Installation and Operation Guide
Detailed guide for installing and operating the Intermatic EI200 electronic in-wall countdown timer. Features include 5-30 minute time ranges, continuous HOLD mode, and ratings for 15A general purpose, 1000W tungsten, and 1/4 HP motors. Includes warranty information.
Aurreview Intermatic KM2 Serieko Hormako Tenporizadorea: Instalazio eta Erabilera Argibideak
Intermatic KM2 Serieko Hormako Tenporizadoreak instalatzeko eta erabiltzeko gida osoa. Ikasi argiztapena eta beste zirkuitu batzuk automatikoki kontrolatzeko ezaugarriak, zehaztapenak, programazioa eta kableatua.
Aurreview Intermatic EI210 Electronic In-Wall Countdown Timer - Installation & Operation Guide
Comprehensive guide for the Intermatic EI210 electronic in-wall countdown timer, detailing features, installation steps, operation modes (Timer and Hold), and warranty information. Includes technical specifications and contact details for Intermatic Incorporated.
Aurreview Intermatic Spring Wound Interval Timer Installation Guide
Comprehensive installation and operation guide for the Intermatic Spring Wound Interval Timer, detailing switch ratings, wiring instructions, applications, and warranty information.