Sarrera
The Intermatic EI215W In-Wall Countdown Timer provides convenient and automatic shut-off for various electrical loads. This timer is designed for silent operation and offers multiple time settings to suit your needs, enhancing energy efficiency and safety in your home or office. It is suitable for controlling lighting, fans, and other appliances.

1. irudia: Aurrealdea view of the Intermatic EI215W In-Wall Countdown Timer, showing the time selection buttons and indicator lights.
Segurtasun Informazioa
OHARRA: To avoid fire, shock, or death, always turn off power at the circuit breaker or fuse box and test that power is off before wiring. Installation should be performed by a qualified electrician or in accordance with local electrical codes. This device is intended for indoor use only.
- Ziurtatu elikadura hornidura deskonektatuta dagoela instalazioa edo mantentze-lanak egin aurretik.
- Do not exceed the maximum electrical ratings of the timer.
- This timer requires a neutral wire for proper operation.
- Use only with compatible electrical loads as specified in the product specifications.
Ezaugarriak
- Provides 15/30/60 Minute, 2/4 Hour time ranges.
- Available in White finish.
- Funtzionamendu isila.
- Replaces single-pole switches in a variety of applications.
- CFL compatible with EI200 series timers (EI210W, EI220W, etc.), EI500C, EI500WC, EI500LAC, EI600C and EI600LAC.
- Designed for use with a decorator-style wall plate (not included).
Paketearen edukia
- Intermatic EI215W In-Wall Countdown Timer
- Instalazio Torlojuak
- Hari intxaurrak
- Argibide eskuliburua
Konfigurazioa eta instalazioa
Follow these steps carefully to install your Intermatic EI215W timer. Ensure all safety precautions are observed.

Figure 2: Wiring diagram for the Intermatic EI215W In-Wall Countdown Timer, showing connections for Hot, Neutral, Load, and Ground wires.
- Turn off power at the circuit breaker and test that power is off before wiring.
- Remove the wall plate and disconnect the light switch. Make sure both 'hot' and 'neutral' wires are present in the junction box. If additional wiring is necessary, it must be completed before installation.
- Connect the black timer wire to the "hot" (usually black or red) wire in the junction box using a wire connector.
- Cut the white wire from the fixture using a wire connector. Connect the white timer wire to the neutral (white) wire in the junction box.
- If the wall switch you are replacing had separate grounding conductors connected to the GREEN screw on the switch, make sure to connect these to the green wire from the timer with a wire connector.
- Egiaztatu hari-konexio guztiak seguru daudela.
- Place all wires inside the junction box. Fit the timer into the junction box. Next, install the timer using the mounting screws furnished.
- Reconnect your electrical power.
Funtzionamendua
To enter timer mode, press and release the push button (for less than 2 seconds) repeatedly to select one of the five time settings or OFF (15 minutes - 30 minutes - 60 minutes - 120 minutes - 240 minutes OFF). The illuminated LED indicators will show the time setting that is selected. The connected load will turn ON. The timer starts counting down until the time runs out, at which point all 5 LEDs will go off and the connected load will turn OFF.
To turn off the timer before the set time expires, repeatedly press the button until all LEDs are off. This will immediately turn off the connected load.
Mantentzea
The Intermatic EI215W timer requires minimal maintenance. Keep the device clean by wiping it with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the wall plate is securely fastened. No user-serviceable parts are inside the unit.
Arazoak konpontzea
| Arazoa | Kausa posiblea | Irtenbidea |
|---|---|---|
| Timer does not turn on/off. | No power to the unit; incorrect wiring; faulty unit. | Check circuit breaker. Verify wiring connections (Hot, Neutral, Load, Ground). If wiring is correct, unit may be faulty and require replacement. |
| LEDak ez dira pizten. | No power; unit not properly reset. | Ensure power is on. Press the button to cycle through settings. |
| Timer turns off prematurely. | Incorrect time setting selected. | Ensure the desired time setting is selected by pressing the button until the correct LED illuminates. |
| Timer does not fit in wall box. | Insufficient space in junction box. | Ensure wires are neatly folded into the back of the box. A deeper electrical box may be required. |
Zehaztapenak
| Atributua | Balioa |
|---|---|
| Modelo zenbakia | EI215W |
| liburukiatage | 120 Volt |
| Wattage | 1800 Watt |
| Aldatu estiloa | SPST (Single-Pole Single-Throw) |
| Denbora tarteak | 15/30/60 Minute, 2/4 Hour |
| Kolorea | Zuria |
| Materiala | Plastikoa |
| Produktuaren neurriak | 1.44" L x 0.75" W x 2.79" H |
| Muntatze Mota | Horma barnean |
| Ziurtagiria | UL (Canada and US) |
Bermearen informazioa
This Intermatic product is covered by a 1-year limited warranty. This warranty covers defects in material and workmanship. It does not cover damage due to improper installation, misuse, abuse, or normal wear and tear. For warranty claims, please contact Intermatic customer support. The warranty provides for unit replacement only and does not cover labor costs.
Bezeroarentzako Arreta
For technical assistance, troubleshooting, or general inquiries regarding your Intermatic EI215W timer, please visit the official Intermatic website or contact their customer support line. Have your model number (EI215W) ready when contacting support for faster service.
Sareko baliabideak: www.intermatic.com