Intermatic MIL72ESTUZH-120

Intermatic MIL72ESTUZH-120 24-Hour 120V Flush Mount Electromechanical Time Control Instruction Manual

Model: MIL72ESTUZH-120

1. Sarrera

This manual provides detailed instructions for the installation, operation, and maintenance of the Intermatic MIL72ESTUZH-120 24-Hour 120V Flush Mount Electromechanical Time Control. Please read this manual thoroughly before attempting to install or operate the device to ensure safe and correct usage.

2. Segurtasun informazioa

OHARRA: Deskarga elektrikoaren arriskua. Deskonektatu zirkuitu-hauslean edo fusible-kutxan korrontea instalazioa edo mantentze-lanak egin aurretik.

  • Kableatu guztiak tokiko eta estatuko kode elektrikoekin bat etorri behar dira.
  • Instalazioa elektrizista kualifikatu batek egin behar du.
  • Do not exceed the maximum electrical ratings of the device.
  • Ziurtatu lurrerako egokia den arrisku elektrikoak saihesteko.
  • Keep children away from electrical devices.

3. Produktua amaitu daview

The Intermatic MIL72ESTUZH-120 is a robust 24-hour electromechanical timer module designed for flush or panel mounting within a control panel. It is suitable for light-duty commercial applications requiring precise time control for 120 VAC single-phase circuits. Common uses include lighting, HVACR systems, pumps, motors, and general electrical circuit management.

Intermatic MIL72ESTUZH-120 24-Hour Electromechanical Time Control with a clear cover, showing the black dial with white markings for hours and minutes, and a manual override switch.

Irudia: Aurrealdea view of the Intermatic MIL72ESTUZH-120 timer. The device features a clear protective cover over a black dial. The dial displays a 24-hour format with AM/PM indicators and minute markings. A central clock mechanism with hour and minute hands indicates the current time. The outer edge of the dial contains captive trippers for setting ON/OFF periods. A manual override switch is visible on the right side of the dial.

Ezaugarri nagusiak:

  • 21 A SPDT Switch: Provides reliable switching for various loads.
  • Synchronous Drive with Self-Recharging Battery Backup: Ensures accurate timekeeping and operation during power outages.
  • Captive Trippers: Allows for easy setting of 15-minute ON/OFF intervals.
  • Eskuz gainditzea: Provides flexibility to temporarily bypass programmed settings.
  • Muntaiaren diseinua: Integrates seamlessly into control panels.

4. Zehaztapenak

ZehaztapenaXehetasuna
Modelo zenbakiaMIL72ESTUZH-120
MarkaIntermatic
liburukiatage120V
Aldatu motaSPDT (Polo Bakarreko Bi Jaurtiketa)
Amparoa21 A
Zikloa24 ordu
Muntatze MotaFlush/Panel Mount
Bateria babeskopiaSelf-recharging Nickel Metal Hydride (non-replaceable)
Minimum ON/OFF Time15 minutes (using captive trippers)
MaterialaMetala
Produktuaren neurriak30"D x 8"W x 6"H (Note: These dimensions appear to be for packaging or a larger assembly, actual timer module dimensions will be smaller for flush mounting.)
Elementuaren pisua4 ontza

5. Instalazioa

Hasi aurretik:

  • Ziurtatu zirkuitu-etengailu nagusian korrontea itzalita dagoela.
  • Egiaztatu hornidura voltage matches the timer's rating (120V AC).
  • Have appropriate tools ready (screwdriver, wire strippers, etc.).

Muntaketa:

  1. Select a suitable location within a control panel for flush mounting.
  2. Cut an appropriate opening in the panel according to the timer's dimensions.
  3. Insert the timer into the opening and secure it using the provided mounting hardware.

Kableatua:

Refer to the wiring diagram provided with the product packaging for specific connections. General wiring steps include:

  1. Connect the incoming 120V AC line wire to the designated terminal.
  2. Konektatu kable neutroa terminal neutrora.
  3. Connect the load wire(s) (e.g., to lights, motor) to the appropriate switched terminals (normally open or normally closed, depending on desired operation).
  4. Ziurtatu konexio guztiak seguru eta isolatuta daudela.

After wiring, restore power and proceed to initial setup.

6. Funtzionamendua

Uneko ordua ezartzea:

  1. Rotate the entire dial clockwise until the current time aligns with the time indicator arrow (usually a small triangle or line on the stationary part of the timer housing).
  2. Ensure you distinguish between AM and PM hours on the 24-hour dial.

ON/OFF programak ezartzea:

The timer uses captive trippers around the dial to set program times. Each tripper represents a 15-minute interval.

  1. To set an ON period, push the trippers outwards for the desired duration.
  2. To set an OFF period, leave the trippers in their inward position for the desired duration.
  3. The timer will activate the connected load when the dial rotates past an outward-pushed tripper and deactivate it when it rotates past an inward-pushed tripper.

Eskuz gainditzea:

The MIL72ESTUZH-120 features a manual override switch, typically a small lever or button, located on the timer face. This allows you to temporarily switch the load ON or OFF, overriding the programmed schedule without affecting future cycles.

  • Move the override switch to the desired position (ON or OFF).
  • The timer will resume its programmed schedule at the next scheduled ON or OFF event.

7. Mantentzea

The Intermatic MIL72ESTUZH-120 is designed for minimal maintenance.

  • Garbiketa: Periodically wipe the exterior of the timer with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Bateria: The unit contains a non-replaceable, self-recharging Nickel Metal Hydride battery for power outage carry-over. No user maintenance is required for the battery.
  • Ikuskapena: Annually inspect the timer for any signs of damage, loose connections, or unusual operation. If any issues are found, disconnect power and consult a qualified electrician.

8. Arazoak

ArazoaKausa posibleaIrtenbidea
Tenporizadorea ez dago martxanNo power to the timer; Motor failureCheck circuit breaker/fuse; Verify wiring connections; Contact support if motor is faulty.
Load not turning ON/OFF at programmed timesIncorrect time setting; Trippers not set correctly; Manual override engagedAdjust current time; Ensure trippers are pushed in/out as desired; Check manual override switch position.
Manual override not workingSwitch mechanism faulty; Internal wiring issueEnsure switch is fully engaged; Contact support if issue persists.
Timer making unusual noisesBarne arazo mekanikoaDisconnect power immediately; Contact support.

9. Bermea eta Laguntza

For warranty information and technical support, please refer to the documentation included with your product or visit the official Intermatic webgunea. Gorde erosketa-agiria erosketaren frogagiri gisa, berme-erreklamazioetarako.

Intermatic Customer Support:

  • Webgunea: www.intermatic.com
  • Contact information can typically be found in the 'Support' or 'Contact Us' section of their webgunea.

Erlazionatutako dokumentuak - MIL72ESTUZH-120

Aurreview Intermatic GM40AV Series Electromechanical Commercial Time Switch: Installation and Operation Manual
Comprehensive installation, operation, and programming guide for the Intermatic GM40AV Series electromechanical commercial time switches. Includes electrical ratings, wiring diagrams, and warranty information.
Aurreview Intermatic T170, T1400 & T1800 Series Electromechanical Time Switches
Comprehensive details on Intermatic T170, T1400, and T1800 Series 24-Hour Electromechanical Time Switches, covering features, specifications, ratings, model variations, and wiring diagrams for commercial, industrial, and residential applications.
Aurreview Intermatic WHQ Serieko 40A Ur-berogailuen Tenporizadoreak Bateria Erreserbarekin - Instalazio eta Erabilera Eskuliburua
Intermatic WHQ Serieko 24 orduko/7 eguneko ur-berogailu elektromekanikoen tenporizadoreei buruzko informazio zehatza, ezaugarriak, zehaztapenak, instalazio-gida, programazio-argibideak eta bermearen informazioa barne. Etxebizitza, merkataritza eta industria-erabilerarako diseinatua.
Aurreview Intermatic T105 24-Hour Dial Time Switch: Installation, Wiring, and Operation Guide
Comprehensive guide for the Intermatic T105 24-hour mechanical dial time switch. Covers model specifications, safety warnings, wiring instructions for various configurations (SPNO, SPNC, SPDT), programming procedures, and manual operation. Includes a detailed table of electrical ratings and wire gauge recommendations.
Aurreview Intermatic T103 24-Hour Dial Time Switch: Installation and Operation Manual
Detailed guide for the Intermatic T103 24-Hour Dial Time Switch, covering specifications, safety warnings, wiring instructions, programming, and operation. Suitable for indoor use with 120/208/240 VAC power.
Aurreview Intermatic T101P201/T101R201 24-Hour Time Switch with Fireman Switch