Intermatic T106R

Intermatic T106R Mechanical Time Switch User Manual

Modeloa: T106R

Sarrera

This manual provides instructions for the installation, operation, and maintenance of the Intermatic T106R Mechanical Time Switch. The T106R is designed to control electrical loads up to 40 Amps, offering direct 24-hour control with up to 12 ON/OFF operations per day. It features a minimum ON/OFF time of 1 hour and includes a manual override function. This device is housed in a durable steel enclosure suitable for indoor and outdoor use.

Segurtasun-argibide garrantzitsuak

Produktua amaituview

The Intermatic T106R Mechanical Time Switch consists of a robust steel enclosure and an internal mechanical timer mechanism.

Intermatic T106R Mechanical Time Switch with open door

1. irudia: Aurrealdea view of the Intermatic T106R Mechanical Time Switch with the enclosure door open, revealing the timer dial and wiring terminals. The gray steel housing and yellow timer mechanism are visible.

Ezaugarri nagusiak

Instalazio-argibideak

WARNING: Ensure power is disconnected at the main circuit breaker before proceeding with installation.

  1. Mounting the Enclosure: Select a suitable location for mounting the timer. The steel enclosure is rated for indoor and outdoor use. Securely mount the enclosure to a flat, stable surface using appropriate hardware through the mounting holes provided.
  2. Kableatu konexioak:
    • Ireki itxiturako atea.
    • Identify the input power terminals (LINE) and output load terminals (LOAD).
    • Connect the incoming power supply wires to the LINE terminals.
    • Connect the wires leading to the electrical load (e.g., pump, lighting) to the LOAD terminals.
    • Ensure all connections are tight and follow the wiring diagram located inside the enclosure or in the separate instruction guide.
    • The T106R is designed for 208-277 Volt applications. Verify your supply voltage matches the timer's rating.
  3. Itxi eta Seguru: Once wiring is complete and verified, close the enclosure door and secure it.
Intermatic T106R Mechanical Time Switch internal view

2 irudia: Gertuko planoa view of the internal components of the Intermatic T106R Mechanical Time Switch, showing the timer dial, wiring terminals, and caution labels. This image highlights the electrical connection points.

Ordu-etengailuaren funtzionamendua

Uneko ordua ezartzea

  1. Rotate the large yellow dial clockwise until the current time aligns with the small arrow or indicator mark on the timer mechanism.
  2. Ensure AM/PM is correctly set if applicable (this model operates on a 24-hour cycle).

ON/OFF zikloen programazioa

The timer uses trippers (pins) on the dial to activate ON and OFF cycles.

  1. Locate the ON (green) and OFF (red) trippers. These are typically small pins that can be pushed in or out, or attached to the dial.
  2. Attach or position the ON tripper at the desired time for the load to turn on.
  3. Attach or position the OFF tripper at the desired time for the load to turn off.
  4. Multiple ON/OFF cycles can be set, up to 12 pairs per 24-hour period. Ensure a minimum of 1 hour between ON and OFF settings.

Eskuzko gainidaztea

The T106R includes a manual override switch, typically a lever or button, that allows you to temporarily turn the load ON or OFF without affecting the programmed schedule.

To use: Move the manual override lever to the desired position (ON or OFF). The timer will resume its programmed schedule at the next scheduled ON or OFF event.

Mantentze-jarraibideak

Ohiko arazoak konpontzea

ArazoaKausa posibleaIrtenbidea
Tenporizadoreak ez du funtzionatzen.No power supply; Incorrect wiring; Trippers not set.Check circuit breaker; Verify wiring connections; Ensure trippers are correctly positioned.
Load does not turn ON/OFF at programmed times.Current time not set correctly; Trippers incorrectly placed; Manual override engaged.Adjust current time; Reposition ON/OFF trippers; Check manual override switch.
Timer makes unusual noise.Barne arazo mekanikoa.Discontinue use and contact a qualified electrician or Intermatic support.

Zehaztapen Teknikoak

Bermea eta Laguntza

The Intermatic T106R Mechanical Time Switch comes with a 1-year limited warranty. This warranty covers defects in materials and workmanship. In the event of a defect, the unit will be replaced. Labor costs are not covered.

For warranty claims or technical support, please contact Intermatic customer service. Refer to the official Intermatic webuneko harremanetarako informazioa lortzeko gunea.

Sareko baliabideak: For additional information, wiring diagrams, or FAQs, visit the official Intermatic webgunea: www.intermatic.com

Erlazionatutako dokumentuak - T106R

Aurreview Intermatic T105 24-Hour Dial Time Switch: Installation, Wiring, and Operation Guide
Comprehensive guide for the Intermatic T105 24-hour mechanical dial time switch. Covers model specifications, safety warnings, wiring instructions for various configurations (SPNO, SPNC, SPDT), programming procedures, and manual operation. Includes a detailed table of electrical ratings and wire gauge recommendations.
Aurreview Intermatic EJ341C/EJ343C Lighting Timer Switch Installation and Programming Guide
Detailed instructions for installing and programming Intermatic EJ341C (Single Pole) and EJ343C (Three Way) lighting timer switches. Covers setup, controls, programming methods, troubleshooting, and specifications.
Aurreview Intermatic DT101 24-Hour Digital Time Switch: Installation and Operation Guide
A comprehensive guide for installing, programming, and operating the Intermatic DT101 24-Hour Digital Time Switch. Covers safety precautions, product specifications, setup, programming, operation modes, and warranty information.
Aurreview Intermatic TIME-ALL HB114 Heavy Duty 240V Timer - Setup and Operation Guide
Comprehensive guide for the Intermatic TIME-ALL HB114 Heavy Duty 240V plug-in timer, covering setup, programming, manual operation, specifications, and safety warnings.
Aurreview Intermatic Spring Wound Interval Timer Installation and Operation Guide
Detailed installation, operation, and application guide for Intermatic spring wound interval timers (FF and FD models). Includes switch ratings, wiring diagrams, and warranty information.
Aurreview Intermatic EJ351 Barruko Hormako Etengailu Tenporizadorea: Instalazio, Programazio eta Arazoak Konpontzeko Gida
Intermatic EJ351 Barruko Hormako etengailu-tenporizadorea instalatzeko, programatzeko eta arazoak konpontzeko gida osoa. Ikasi ordutegiak nola ezarri, modu automatikoak eta eskuzkoak nola erabili eta ohiko arazoak nola konpondu.