Intermatic T102

Intermatic T102 24-Hour Mechanical Time Switch User Manual

Eredua: T102

Marka: Intermatic

Produktua amaituview

The Intermatic T102 is a robust 24-hour mechanical time switch designed for industrial, commercial, and residential applications. This device provides direct control of various loads, offering up to 12 'On/Off' operations daily with minimum on/off times of 1 hour. It is equipped with one 'On' and one 'Off' tripper for precise scheduling. Its durable steel construction ensures reliable performance.

Segurtasun informazio garrantzitsua

OHARRA: Produktu honek produktu kimikoen eraginpean jar dezake, besteak beste, beruna, Kaliforniako Estatuak minbizia eta jaiotza-akatsak edo ugalketa-kalte batzuk eragiten dituela ezagutzen duena. Informazio gehiago lortzeko, joan www.P65Warnings.ca.gov.

Always turn off power at the main panel before installing or servicing this switch. Failure to do so may result in serious injury or death from electrical shock. Ensure all wiring is performed by a qualified electrician and complies with all local and national electrical codes. Do not connect aluminum wires to switch terminals.

Ezaugarri nagusiak

Konfigurazioa eta Instalazioa

Installation of the Intermatic T102 time switch should be performed by a qualified professional in accordance with all applicable electrical codes. For detailed wiring diagrams and step-by-step instructions, please refer to the official user guide PDF.

Download the official User Guide (PDF): Intermatic T102 User Guide

Produktuen Diagrama

Intermatic T102 Mechanical Time Switch with cover open, showing internal components and dial.

Image: The Intermatic T102 mechanical time switch with its metal enclosure door open, revealing the yellow 24-hour dial, the manual override lever, and the wiring terminals (Neutral, Line, Load). A warning label regarding aluminum wires is visible at the bottom.

Installation and Operation Video

Bideoa: Amaiera batview of the Intermatic T100 series 24-hour mechanical time switches, highlighting features such as direct 24-hour control, support for loads up to 40A per pole, simple installation, and operation. It demonstrates how to set the time dial, adjust 'On' and 'Off' trippers, and use the manual override switch. The video also emphasizes the product's durability, with many devices still in operation after 50+ years.

Funtzionamendua

Ordua ezartzea

To set the current time, gently pull the dial outwards and rotate it until the current time aligns with the 'TIME SET' arrow. Ensure the dial is pushed back in after setting.

Setting On/Off Trippers

The time switch comes with one 'On' tripper and one 'Off' tripper. These trippers are small pins that are inserted into slots around the perimeter of the dial. Position the 'On' tripper at the desired time for the load to turn on, and the 'Off' tripper at the desired time for the load to turn off. Additional trippers can be purchased separately to allow for up to 12 'On/Off' operations per day.

Eskuzko gainidaztea

The time switch features a manual override lever located below the dial. This lever allows you to manually switch the load 'On' or 'Off' without affecting the programmed schedule. Simply move the lever to the 'On' or 'Off' position as needed. The timer will resume its programmed schedule at the next scheduled 'On' or 'Off' event.

Zehaztapen Teknikoak

ZehaztapenaXehetasuna
Modelo zenbakiaT102
liburukiatage208-277-Volt
Aldatu estiloaSPST
Mota24 orduko ordu-etengailu mekanikoa
MaterialaAltzairua
Produktuaren neurriak3.44" L x 5.13" W x 7.88" H
Elementuaren pisua1 kilo
Max. Number of Operations12 egunean
Min. On/Off Time1 ordu
ZiurtagiriakUL (Canada and US), CSA (Canada and US)
UPC078275102217

Mantentzea

The Intermatic T102 time switch is designed for minimal maintenance. Periodically inspect the unit for any signs of damage or loose connections. Keep the enclosure clean and free from dust and debris. Do not attempt to lubricate any internal components. For any issues beyond basic cleaning, contact a qualified electrician or Intermatic customer support.

Arazoak konpontzea

If the time switch is not operating as expected, first ensure that power is supplied to the unit and that the manual override lever is not in an unintended position. Verify that the 'On' and 'Off' trippers are correctly placed on the dial and that the dial is not stuck. If the clock motor is not turning, or if the unit fails to switch loads, consult the detailed troubleshooting section in the official user guide PDF or contact Intermatic customer support.

Bermea eta Laguntza

The Intermatic T102 Mechanical Time Switch comes with a 1-year limited warranty. For warranty claims or technical support, please contact Intermatic directly.

For more information about Intermatic products and support, visit the official Intermatic Store: Intermatic Store on Amazon

Erlazionatutako dokumentuak - T102

Aurreview Intermatic ET1100 Series Electronic Time Switches: Features, Specifications, and Models
Detailed information on the Intermatic ET1100 Series 24-Hour Electronic Time Switches, including features, technical specifications, contact ratings, enclosure options, and model variations for accurate load control.
Aurreview Intermatic ET100 Series Electronic 24 Hour Time Switch Owner/Installer Manual
Comprehensive owner and installer instructions for the Intermatic ET100 Series electronic 24-hour time switches, including models ET102C, ET102CM, ET104C, and ET104CM. Covers installation, programming, troubleshooting, and warranty information.
Aurreview Intermatic T170, T1400 & T1800 Series Electromechanical Time Switches
Comprehensive details on Intermatic T170, T1400, and T1800 Series 24-Hour Electromechanical Time Switches, covering features, specifications, ratings, model variations, and wiring diagrams for commercial, industrial, and residential applications.
Aurreview Intermatic T101P201/T101R201 24-Hour Time Switch with Fireman Switch
Detailed guide for Intermatic T101P201 (plastic) and T101R201 (metal) 24-hour dial time switches with fireman switch functionality for pool heaters. Includes wiring, programming, and operating instructions.
Aurreview Intermatic T103 24-Hour Dial Time Switch: Installation and Operation Manual
Detailed guide for the Intermatic T103 24-Hour Dial Time Switch, covering specifications, safety warnings, wiring instructions, programming, and operation. Suitable for indoor use with 120/208/240 VAC power.
Aurreview How to Install and Operate Intermatic E-1020 24-Hour In-Wall Timer
Comprehensive guide for installing and operating the Intermatic E-1020 24-hour multiple program in-wall mechanical timer. Includes wiring instructions, programming steps, and warranty information.