1. Sarrera eta Overview

The Altronix 6062 Multi-Function Timer is a versatile programmable timer designed for various applications requiring precise timing control. It operates on either 12VDC or 24VDC and features SPDT (Single Pole Double Throw) contacts rated at 8 amp/115VAC. This unit offers an adjustable timing range from 1 second to 60 minutes, with a unique capability to provide a momentary relay activation at the conclusion of a set timing cycle.

This manual provides essential information for the proper installation, operation, and maintenance of your Altronix 6062 Multi-Function Timer.

2. Ezaugarriak

  • Multi-function programmable timer.
  • Flexible power input: 12VDC or 24VDC operation.
  • High-capacity SPDT contacts rated at 8 amp/115VAC.
  • Wide adjustable timing range: 1 second to 60 minutes.
  • Features momentary relay activation at the end of the timing cycle.
  • Diseinu trinkoa eta iraunkorra.
  • AEBetan fabrikatua
  • RoHS betetzen.

3. Konfigurazioa eta instalazioa

Segurtasun informazio garrantzitsua: Installation should be performed by qualified personnel in accordance with all local and national electrical codes. Disconnect all power before installation or servicing.

3.1. Muntaketa

Mount the Altronix 6062 timer in a secure, dry location, away from excessive heat or moisture. Ensure adequate ventilation around the unit.

3.2. Kableatua

The Altronix 6062 timer requires a 12VDC or 24VDC power source. Connect the power supply to the designated input terminals, observing correct polarity. The unit features SPDT contacts for controlling external devices. Wire your load to the Normally Open (NO) or Normally Closed (NC) contacts and the Common (C) terminal as required by your application. Refer to the product's included wiring diagram for specific connection points.

Altronix 6062 Multi-Function Timer product packaging

Image of the Altronix 6062 Multi-Function Timer in its blue and white retail box, displaying the model number, key features, and Altronix branding.

4. Funtzionamendu-argibideak

4.1. Setting the Timing Range

The Altronix 6062 allows for an adjustable timing range from 1 second to 60 minutes. The timing duration is typically set via an onboard potentiometer or dip switches. Carefully adjust the setting to achieve the desired delay for your application. Test the timing repeatedly to ensure accuracy.

4.2. Momentary Relay Activation

This timer includes a feature for momentary relay activation at the completion of the set timing cycle. This can be utilized to trigger a brief event or signal after the primary delay has elapsed. Consult the specific wiring and configuration details provided with your unit for enabling and utilizing this function.

5. Mantentzea

The Altronix 6062 Multi-Function Timer is designed for reliable, maintenance-free operation under normal conditions. To ensure optimal performance and longevity:

  • Aldian-aldian ikuskatu kableatu-konexio guztiak, ondo finkatuta daudela eta korrosiorik gabe daudela ziurtatzeko.
  • Keep the unit free from dust, dirt, and debris. Use a soft, dry cloth for cleaning.
  • Do not expose the unit to extreme temperatures, humidity, or direct water contact.
  • Ez saiatu c irekitzen.asing or service internal components. Refer all servicing to qualified personnel.

6. Arazoak

If you encounter issues with your Altronix 6062 Multi-Function Timer, consider the following troubleshooting steps:

  • No Power/Unit Not Functioning:
    • Verify that the correct DC input voltage (12VDC or 24VDC) is applied to the power terminals.
    • Check for correct power supply polarity.
    • Ziurtatu energia-konexio guztiak seguruak direla.
  • Incorrect Timing/Relay Not Activating:
    • Re-adjust the timing potentiometer or settings to the desired duration.
    • Confirm that the load connected to the SPDT contacts is within the specified 8 amp/115VAC rating.
    • Check all load wiring connections for security and continuity.
    • Ensure the timing cycle is completing as expected before the relay is supposed to activate.

For persistent issues or problems not covered here, please contact Altronix technical support.

7. Zehaztapenak

AtributuaXehetasuna
FabrikatzaileaAltronix Corporation
Zati zenbakia6062
Elementuaren eredu-zenbakia6062SP
Potentzia Sarrera12VDC edo 24VDC
Kontaktu motaSPDT (Single Pole Double Throw)
Kontaktuen balorazioa8 amp/115VAC
Denbora tartea1 segundotik 60 minutura
Elementuaren pisua2.08 ontza
Produktuaren neurriak1 x 1 x 1 hazbete
MaterialaBeira-zuntza
Eskuragarri dagoen lehen data25ko uztailaren 2010a
RoHS betetzen duenaBai

8. Bermea eta Laguntza

Altronix products are engineered for superior performance and reliability. The Altronix 6062 Multi-Function Timer is backed by a Bizi osorako bermea, ensuring long-term peace of mind.

For technical support, warranty claims, or additional product information, please visit the official Altronix webwebgunera edo jarri harremanetan bezeroarentzako arreta-zerbitzuarekin:

Webgunea: altronix.com

Please have your product model number (6062) and any relevant purchase information ready when contacting support.

Erlazionatutako dokumentuak - 6062

Aurreview Altronix RB30 Relay Module: Specifications and Operation
Detailed specifications and operating instructions for the Altronix RB30 Relay Module, featuring 12VDC/24VDC operation, 30A contacts, and UL recognition.
Aurreview Altronix RBST Relay Module: Specifications and Wiring Configurations
Detailed specifications and wiring diagrams for the Altronix RBST Relay Module, covering dry contacts, polarity reversal, latching dry contacts, and line seizure applications. Includes product information and contact details.
Aurreview Altronix 6062 Multi-purpose Timer: Installation and Application Guide
Detailed guide for the Altronix 6062 Multi-purpose Timer, covering specifications, installation instructions, dip switch and jumper settings, terminal identification, and typical applications for access control, security systems, and automation.
Aurreview Altronix RBSN Relay Module Specifications and Wiring
Detailed specifications and wiring diagrams for the Altronix RBSN Relay Module, including operation, contacts, and mounting.
Aurreview Altronix RB5 Relay Module: Specifications and Application Diagrams
The Altronix RB5 Relay Module offers selectable 6VDC or 12VDC operation with 5A DPDT contacts. It supports Dry Contacts, Polarity Reversal, Latching Dry Contacts, and Line Seizure applications, ideal for security and control systems. Snap track mountable.
Aurreview Altronix OLS120 Power Supply Charger Installation Guide | Technical Specifications
Detailed installation guide and technical specifications for the Altronix OLS120 Off-Line Power Supply/Charger, covering overview, input/output, battery backup, supervision, and terminal identification.