Littelfuse SC-30

Littelfuse Bussmann SC-30 Fuse Instruction Manual

1. Sarrera

This manual provides essential information for the safe and effective use of the Littelfuse Bussmann SC-30 Fuse. It covers product overview, safety guidelines, installation, and specifications. Please read this manual thoroughly before handling or installing the fuse.

2. Segurtasun informazioa

WARNING: Electrical shock hazard. Always disconnect power before installing or replacing fuses. Installation should only be performed by qualified personnel.

  • Ensure the power supply is completely disconnected and locked out before any work involving fuses.
  • Never touch electrical components with wet hands or while standing on wet surfaces.
  • Erabili beti bolumen egokia duten fusibleaktage eta amperage ratings for the circuit they are protecting. Using an incorrect fuse can lead to equipment damage, fire, or personal injury.
  • Ez saihestu edo tamper with fuses.
  • Wear appropriate personal protective equipment (PPE), such as insulated gloves and safety glasses, when working with electrical systems.

3. Produktua amaitu daview

The Littelfuse Bussmann SC-30 is a Class G, time-delay cartridge fuse designed for general purpose basic protection against overcurrents. It is rated for 30 Amperes and suitable for both AC (480V) and DC (300V) applications. The time-delay characteristic allows for temporary overcurrents, such as motor starting surges, without blowing, while still providing protection against sustained overloads and short circuits.

Bussmann SC-30 Class G Time-Delay Fuse with green label

3.1. irudia: Aurrealdea view of the Bussmann SC-30 fuse, showing the green label with "BUSS Class G Fuse Type Ampere SC-30 Time-Delay" markings.

Bussmann SC-30 General Purpose Time-Delay Class G Fuse with white label

3.2. irudia: Aldea view of the Bussmann SC-30 fuse, displaying detailed specifications including "General Purpose Basic Protection Time-Delay Class G Fuse SC-30 480Vac AC IR 100kA 300Vdc DC IR 10kA".

4. Instalazioa

Follow these steps for proper installation of the SC-30 fuse:

  1. Egiaztatu bateragarritasuna: Ensure the SC-30 fuse matches the required amparoa eta voltage ratings for your specific electrical circuit and equipment. Refer to your equipment's documentation.
  2. Deskonektatu energia: Absolutely ensure all power to the circuit where the fuse will be installed is turned off and locked out. Use a voltage tester to confirm the circuit is de-energized.
  3. Remove Old Fuse (if applicable): Carefully remove the existing fuse from its holder. Note its orientation if it's a specific type.
  4. Sartu fusible berria: Insert the Bussmann SC-30 fuse into the fuse holder. Ensure it is seated firmly and correctly. Do not force the fuse.
  5. Berrezarri boterea: Once the fuse is securely in place and all safety checks are complete, restore power to the circuit.
  6. Proba funtzionaltasuna: Verify that the protected equipment operates as expected.

Note: Fuses are designed for one-time use. A blown fuse must be replaced with a new one of the identical type and rating.

5. Funtzionamendu-printzipioa

The Bussmann SC-30 fuse functions as a sacrificial device designed to protect electrical circuits from overcurrent conditions. When the current flowing through the circuit exceeds the fuse's 30 Ampere rating for a sustained period (due to an overload) or instantaneously (due to a short circuit), the metallic element inside the fuse melts, creating an open circuit. This action interrupts the flow of electricity, preventing damage to wiring, equipment, and reducing the risk of fire.

As a time-delay fuse, the SC-30 is engineered to withstand temporary current surges that are common during the startup of motors or other inductive loads. This prevents nuisance blowing while still providing reliable protection against harmful overcurrents.

6. Mantentzea

Fuses are generally maintenance-free components. However, periodic visual inspection of the fuse and its holder is recommended, especially in environments prone to vibration, dust, or extreme temperatures. Look for any signs of physical damage, discoloration, or loose connections. If any issues are observed, disconnect power and address them immediately.

7. Arazoak

If a circuit protected by an SC-30 fuse stops functioning, the fuse may have blown. Follow these troubleshooting steps:

  • Identify Blown Fuse: Disconnect all power to the circuit. Visually inspect the fuse for a broken filament or discoloration, which indicates it has blown. Some fuse holders may have an indicator.
  • Determine Cause: A blown fuse indicates an overcurrent condition. Investigate the circuit for potential causes such as:
    • Overloaded circuit (too many devices drawing power).
    • Short circuit in wiring or equipment.
    • Faulty equipment connected to the circuit.
  • Ordeztu fusiblea: Once the cause of the overcurrent is identified and rectified, replace the blown fuse with a new Littelfuse Bussmann SC-30 fuse. Never replace it with a fuse of a different rating.
  • Repeated Blowing: If the fuse blows repeatedly after replacement, it indicates a persistent problem in the circuit or equipment. Consult a qualified electrician to diagnose and repair the issue.

8. Zehaztapenak

ZehaztapenaBalioa
MarkaLittelfuse (Bussmann)
Modelo zenbakiaSC-30
Amperage Balorazioa30 Amps
AC Boltage Balorazioa480 Vac
DC bolumenatage Balorazioa300 Vdc
Interrupting Rating (AC)100 kA
Interrupting Rating (DC)10 kA
Fusible motaClass G, Time-Delay
MaterialaKobrea
Muntatze MotaSurface Mount (Cartridge)
Elementuaren pisua0.317 ontza
Paketearen neurriak2.56 x 1.1 x 0.43 hazbete

9. Bermea eta Laguntza

For warranty information and technical support regarding your Littelfuse Bussmann SC-30 fuse, please refer to the official Littelfuse webwebgunera edo jarri harremanetan zuzenean bezeroarentzako arreta-zerbitzura. Gorde erosketa-agiria berme-erreklamazioetarako.

Littelfuse Official Webgunea: www.littelfuse.com

Erlazionatutako dokumentuak - SC-30

Aurreview Littelfuse JLLN Series Class T Fuses | Fast-Acting, High Interrupting Capacity
Explore Littelfuse JLLN Series Class T fuses, offering compact design, fast-acting overload and short-circuit protection, and high interrupting ratings up to 200,000 AIR. Ideal for drives, inverters, and power supplies. View specifications, ordering information, and dimensions.
Aurreview Littelfuse POWR-SPEED L70QS Series High-Speed Fuses - Technical Data
Explore the Littelfuse POWR-SPEED® L70QS Series high-speed fuses. This datasheet provides detailed specifications, dimensions, time-current curves, and application information for these 700V ac/dc fuses, designed for protecting power semiconductor devices in industrial applications.
Aurreview Littelfuse Sealed M10 ZCASE Fuse Installation Instructions
Installation instructions for the Littelfuse Sealed M10 ZCASE Fuse, including specifications, ordering information, and step-by-step assembly guide.
Aurreview CT biraketa-erlazioaren aldaketa gida: Littelfuse ohar teknikoa
Ikasi Littelfuse korronte-transformadoreen (CT) bira-erlazioa nola aldatu ohar tekniko honekin, birak gehitzeko eta kentzeko metodoak eta adibide praktikoak barne.ampCT funtzionamenduaren printzipioak eta erlazio doikuntzak ulertu.
Aurreview Littelfuse MEGA® Flex Series Bolt-Down Fuse Holder
Discover the Littelfuse MEGA® Flex Series 32V Bolt-Down Fuse Holder, designed for high-current applications up to 500 amps. Learn about its features, benefits, and ordering information for this versatile fuse holder.
Aurreview Littelfuse Protection Relays: Comprehensive Catalog for Industrial Safety and Efficiency
Explore the Littelfuse range of protection relays, including advanced solutions for ground-fault protection, arc-flash mitigation, motor and pump monitoring, feeder protection, and neutral grounding systems. Enhance industrial safety and operational efficiency.