1. Produktua amaitu daview
The Linear IEI 212w is an indoor/outdoor flush-mount keypad designed for access control applications. This weather-resistant membrane keypad provides secure entry and is suitable for various environments.

Image of the IEI 212w Indoor/Outdoor Flush-mount Keypad, showing its compact design suitable for flush mounting.
2. Segurtasun informazioa
- Irakurri arretaz argibide guztiak instalatu eta martxan jarri aurretik.
- Ensure power is disconnected before performing any installation or maintenance.
- This device operates on 120 Volts AC. Improper wiring can cause electrical shock or damage to the unit.
- While the keypad is water-resistant, avoid direct high-pressure water jets or prolonged submersion.
- Only use mounting hardware provided or specified by the manufacturer.
- Mantendu haurren eskura.
3. Paketearen edukia
Egiaztatu elementu guztiak paketean daudela:
- IEI 212w Keypad Unit
- Muntatzeko Hardwarea
- Erabiltzailearen eskuliburua (dokumentu hau)
4. Konfigurazioa eta instalazioa
The IEI 212w keypad is designed for flush-mount installation, suitable for both indoor and outdoor environments. Proper installation ensures optimal performance and longevity.
4.1 Gunearen hautaketa
- Choose a flat, stable surface for flush mounting.
- Ensure adequate space behind the mounting surface for wiring and the keypad's depth.
- For outdoor installations, select a location that offers some protection from extreme weather conditions, although the unit is water-resistant.
4.2 Kableatua
- Disconnect power to the installation area before beginning any wiring.
- Connect the keypad to a 120 Volts Corded Electric power source according to local electrical codes and the keypad's wiring diagram (refer to the diagram provided with the unit, not included in this general manual).
- Ziurtatu konexio guztiak seguru eta isolatuta daudela zirkuitu laburrak saihesteko.
4.3 Muntaketa
- Prepare the opening in the mounting surface according to the dimensions specified in the product's detailed installation guide.
- Insert the keypad into the prepared opening.
- Secure the keypad using the provided mounting hardware. Do not overtighten screws.
5. Funtzionamendu-argibideak
The IEI 212w keypad provides access control through a combination of push-button input and remote control capabilities.
5.1 Oinarrizko funtzionamendua
- To gain access, enter your pre-programmed access code using the push buttons on the keypad.
- The keypad will provide visual or audible feedback upon successful code entry.
5.2 Urruneko kontrola
The keypad supports remote control functionality. Refer to the specific remote control's manual for pairing and operation instructions. The remote allows for convenient activation without direct interaction with the keypad.
5.3 Programming Access Codes
Programming new access codes or modifying existing ones typically involves entering a master programming code followed by the desired new code. Consult the detailed programming guide specific to the IEI 212w for step-by-step instructions on managing user codes and system settings.
6. Mantentzea
Regular maintenance ensures the longevity and reliable operation of your IEI 212w keypad.
- Garbiketa: Garbitu teklatuaren gainazala zapi leun batekin,amp cloth. Do not use abrasive cleaners or solvents, as these can damage the membrane and finish.
- Ikuskapena: Periodically check the keypad for any signs of damage, loose connections, or wear. Ensure the flush mount remains secure.
- Ingurumena babestea: For outdoor installations, ensure drainage around the unit is clear to prevent water accumulation.
7. Arazoak
If you encounter issues with your IEI 212w keypad, refer to the following common troubleshooting steps:
| Arazoa | Kausa posiblea | Irtenbidea |
|---|---|---|
| Teklatuak ez du erantzuten | No power; Loose wiring; Internal fault | Check power supply and connections. Ensure circuit breaker is on. If problem persists, contact support. |
| Access code not working | Incorrect code entered; Code not programmed; Keypad malfunction | Verify the access code. Re-program the code if necessary (refer to programming guide). |
| Urruneko kontrola ez dabil | Remote battery low; Remote not paired; Obstruction | Replace remote battery. Re-pair remote with keypad. Ensure clear line of sight if applicable. |
Urrats hauek arazoa konpontzen ez badute, jarri harremanetan bezeroarentzako arreta-zerbitzuarekin.
8. Zehaztapenak
Key technical specifications for the Linear IEI 212w keypad:
- Modelo zenbakia: IEI 212w
- Marka: Lineala
- Instalazio mota: Flush mendia
- Barruko/Kanpoko erabilera: Barruan/Kanpoan
- Energia iturria: Kable elektrikoa
- liburukiatage: 120 Volt
- Kontrol-metodoa: Urrutiko agintea, botoia sakatuz
- Materiala: Aluminioa
- Uraren erresistentzia maila: Urarekiko erresistentea
- Elementuaren pisua: 2 kilo
- Dakarten osagaiak: Muntatzeko Hardwarea
- Fabrikatzailea: iEi Electronics / Linear
- ASIN: B004YHJAXS
9. Bermea eta Laguntza
For warranty information, please refer to the warranty card included with your product or visit the official Linear webgunea. Berme-baldintzek normalean materialen eta fabrikazioaren akatsak estaltzen dituzte erosketa-datatik aurrerako denbora-tarte jakin batean.