1. Produktua amaitu daview
The Sicce Ultrazero Flat Sucking Pump is designed for efficient removal of water from various areas, including flooded cellars, garages, and other spaces where minimal residual water is desired. This submersible pump is capable of reducing water levels down to 2-3 mm.
Ezaugarri nagusiak:
- Capable of pumping water down to 2 mm residual level.
- Fully submersible design.
- Handles dirt particles up to 3 mm in size.
- Equipped with a 10-meter power cable.
- Features a practical carry handle for easy transport.

1 Irudia: Gainetikview of the Sicce Ultrazero Flat Sucking Pump.
2. Segurtasun informazioa
Read all safety warnings and instructions before operating the pump. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Always disconnect the pump from the power supply before handling, cleaning, or performing any maintenance.
- Ziurtatu elikadura hornidura boltage matches the pump's specifications (230 V/50 Hz).
- Do not operate the pump with a damaged power cord or plug. If damaged, it must be replaced by the manufacturer, service agent, or similarly qualified persons to avoid a hazard.
- Do not use the pump to handle flammable or explosive liquids.
- Mantendu haurrak eta baimenik gabeko pertsonak funtzionamendu-eremutik urrun.
- Ensure the pump is fully submerged during operation to prevent overheating.
- Avoid running the pump dry for extended periods.
- This pump is designed for water only. Do not use it for other liquids without consulting the manufacturer.
3. Konfigurazioa eta instalazioa
Follow these steps to properly set up your Ultrazero pump:
- Deskargatu ponpa: Carefully remove the pump and all accessories from the packaging. Inspect for any damage.
- Connect the Discharge Hose:
The pump features a 26.44 mm (3/4") AG pressure connection. Attach a suitable discharge hose (e.g., 20 mm (3/4") hose connection) to this outlet. Ensure the connection is secure to prevent leaks.

Figure 2: Close-up of the pump's discharge outlet and integrated carry handle.
- Ponpa kokatu: Place the pump directly on the surface from which water needs to be removed. Ensure the pump is stable and upright. The flat base allows for efficient water removal down to minimal levels.
- Route the Discharge Hose: Direct the discharge hose to a suitable drainage area, ensuring the water will not flow back into the area being drained.
- Potentzia-konexioa: Plug the 10-meter power cable into a grounded 230 V/50 Hz electrical outlet. Ensure the outlet is protected by a Ground Fault Circuit Interrupter (GFCI) for added safety, especially in wet environments.

Figure 3: The flat base of the pump designed for low residual water levels.
4. Funtzionamendu-argibideak
The Ultrazero pump is designed for simple operation:
- Urperatu ponpa: Ensure the pump is fully submerged in the water you wish to remove. The pump requires water to cool its motor and operate correctly.
- Hasi ponpatzen: Once submerged and connected to power, the pump will begin operating automatically. It does not feature a float switch, so manual monitoring is required for optimal use.
- Uraren maila kontrolatzea: The pump will continue to operate until the water level reaches its minimum suction capability of 2-3 mm.
- Ponpatzeari utzi: To stop the pump, disconnect it from the power supply. It is recommended to disconnect the pump once the desired water level is reached or if the pump starts to run dry.

Figure 4: The Ultrazero pump effectively draining water from a small pool.

Figure 5: The pump in action on a flooded floor, demonstrating its low-level suction capability.

Figure 6: Illustration of the pump's ability to reduce water levels to approximately 2 mm.
5. Mantentzea
Mantentze-lan erregularrak zure ponparen iraupena eta errendimendu optimoa bermatzen ditu.
- Garbiketa: After each use, especially when pumping dirty water, rinse the pump thoroughly with clean water. This helps prevent sediment buildup.
- Hondakinak ikusteko: Periodically check the pump's intake area for any debris (e.g., leaves, small stones) that might obstruct water flow. Remove any blockages carefully after disconnecting power.
- Kableen ikuskapena: Regularly inspect the power cable for cuts, abrasions, or other damage. Do not use the pump if the cable is damaged.
- Biltegiratzea: When not in use, store the pump in a clean, dry place, protected from frost.

Figure 7: The pump can also be used for transferring water for tasks like garden watering from a rain barrel.
6. Arazoak
If you encounter issues with your Ultrazero pump, refer to the following common problems and solutions:
| Arazoa | Kausa posiblea | Irtenbidea |
|---|---|---|
| Ponpa ez da martxan jartzen. | Ez dago elikadura hornidurarik. Elektrizitate-kablea hondatuta dago. Motorraren gainkarga babesa aktibatuta. | Egiaztatu korronte konexioa eta entxufea. Inspect cable for damage; replace if necessary (by qualified personnel). Disconnect power, allow motor to cool, then reconnect. |
| Ponpa martxan dago baina ez da urik isurtzen. | Intake blocked. Discharge hose kinked or blocked. Airlock in pump. | Disconnect power, clear intake. Check and clear discharge hose. Briefly lift and lower the pump while submerged to release trapped air. |
| Reduced pumping performance. | Partial blockage. Impeller worn. | Disconnect power, clean pump intake and impeller area. Contact customer support for service. |
| Ponpa ustekabean gelditu da. | Overheating due to low water level or blockage. Matxura elektrikoa. | Disconnect power, check water level and clear blockages. Allow to cool. Arazoak jarraitzen badu, jarri harremanetan bezeroarentzako arreta-zerbitzuarekin. |
If the problem persists after attempting these solutions, please contact Sicce customer support.
7. Zehaztapen Teknikoak
Detailed specifications for the Sicce Ultrazero Flat Sucking Pump, Model 925607:
| Zehaztapena | Balioa |
|---|---|
| Marka | Sicce |
| Modelo zenbakia | 925607 |
| Max. Delivery Rate (Flow Rate) | 3000 l/h |
| Max. Entrega-Altuera | 3.1 m |
| Power Consumption (P1) | 80 W |
| Bolumen eragileatage | 220-240V/50Hz |
| Conductor Length (Power Cable) | 10 m (three-core, indoor and outdoor use) |
| Presio-konexioa | 26.44 mm (3/4") AG |
| Hose Connection Diameter | 20 mm (3/4") |
| Max. Solids Size | 3 mm |
| Hondar-ur maila | Down to 2-3 mm |
| Produktuaren neurriak (gutxi gorabehera) | 140 mm (Diameter) x 160 mm (Height) / 5.5" x 6.3" |
| Elementuaren pisua | 2.6 kg (5.72 lb) |
| Flotagailu etengailua | Ez |
| Gainkargaren babesa | No (Internal thermal protection may exist, but no external reset) |
| Jatorria | Italian egina |

Figure 8: Technical drawing illustrating the pump's dimensions and 3/4" GAS connection.
8. Bermea eta Laguntza
For warranty information or technical support regarding your Sicce Ultrazero Flat Sucking Pump, please contact Sicce customer service. Keep your purchase receipt and model number (925607) handy when contacting support.
Fabrikatzailea: Ebara
Marka: Sicce
For further assistance, visit the official Sicce webgunearekin edo jarri harremanetan zure tokiko banatzailearekin.