The Johnson Controls TE-6100-2 Series Nickel Temperature Sensing Element is designed for a wide variety of temperature sensing applications. This unit features a nickel sensor element, providing specific resistance ranges suitable for various control systems. It is often used in HVAC systems as an accessory for thermostats.

Ezaugarri nagusiak hauek dira:

  • Nickel Sensor Element: Provides specific resistance ranges for diverse applications.
  • Conduit Box Design: Facilitates secure and protected wiring connections.
  • Averaging Capability: Designed for 8-foot averaging temperature sensing.
Johnson Controls TE-6100-2 Nickel Temperature Sensing Element with conduit box and 8-foot averaging wires.

Figure 1: Johnson Controls TE-6100-2 Nickel Temperature Sensing Element. This image shows the metallic conduit box with an attached label indicating "TE-6100-2 AVERAGING TEMP. SENSOR 1000 OHM-8 FOOT" and several copper wires extending from the top, coiled for an 8-foot averaging length.

2. Konfigurazioa eta instalazioa

Proper installation is crucial for accurate temperature sensing. This device is intended for use by qualified personnel.

2.1 Segurtasun-neurriak

  • Disconnect all power to the system before installation to prevent electrical shock or equipment damage.
  • Jarraitu tokiko eta estatuko kode elektriko guztiak.
  • Ensure proper grounding of the conduit box if required by local codes.

2.2 Muntaketa

The TE-6100-2 can be mounted using various optional mounting assemblies, such as brackets or wall plates, depending on the application requirements. Secure the conduit box firmly to a stable surface in the desired sensing location.

2.3 Kableatua

Connect the sensor wires to the appropriate terminals on your control system or thermostat. Refer to the wiring diagram provided with your specific control system for correct connections. The nickel sensor element provides a 1000 ohm resistance at a reference temperature (typically 70°F or 21°C).

  • Ziurtatu konexio guztiak seguru eta isolatuta daudela.
  • Avoid routing sensor wires near sources of electromagnetic interference.

3. Funtzionamendua

The TE-6100-2 functions by changing its electrical resistance in response to temperature variations. This resistance change is then interpreted by a compatible control system (e.g., a thermostat or building management system) to regulate heating, ventilation, or air conditioning.

  • The sensor provides an 8-foot averaging temperature measurement, meaning it senses the average temperature along its 8-foot length.
  • The 1000 ohm nickel element offers specific resistance characteristics that must be matched with the input requirements of the connected controller.

Once installed and wired correctly, the sensor continuously provides temperature data to the connected control system without requiring user interaction.

4. Mantentzea

The Johnson Controls TE-6100-2 is designed for reliable, long-term operation with minimal maintenance. Regular inspection can help ensure optimal performance.

  • Aldizkako ikuskapena: Annually inspect the sensor and its wiring for any signs of physical damage, corrosion, or loose connections.
  • Garbiketa: If the conduit box or sensor wires accumulate dust or debris, gently clean them with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Ingurumen-baldintzak: Ensure the sensor remains within its specified operating environmental conditions to prevent premature failure.

5. Arazoak

If the temperature sensing system is not functioning as expected, consider the following troubleshooting steps:

  • Irakurketarik ez edo irakurketa okerra:
    • Verify that power is supplied to the control system.
    • Egiaztatu kableatu guztien konexioak estu daudela eta polaritate zuzena dutela.
    • Inspect the sensor wires for any breaks or damage.
    • Ensure the sensor type (nickel 1000 ohm) is correctly configured in the connected control system.
  • Etengabeko irakurketak:
    • Egiaztatu kable bidezko konexio solteak.
    • Investigate potential sources of electromagnetic interference near the sensor wiring.
  • Sentsorearen kaltea: If the sensor or its wires are physically damaged, replacement may be necessary.

If issues persist after performing these checks, consult a qualified HVAC technician or contact Johnson Controls technical support.

6. Zehaztapenak

Ezaugarri Zehaztapena
Modelo zenbakia TE-6100-2
Sentsore mota Nickel Temperature Sensing Element
Erresistentzia 1000 ohms (+/-1%)
Averaging Length 8 oin
Produktuaren neurriak 11.5 x 9 x 3 hazbete
Elementuaren pisua 1.15 kilo
Fabrikatzailea Johnson Controls Inc.

7. Bermearen informazioa

Specific warranty details for the Johnson Controls TE-6100-2 are typically provided at the point of purchase or can be found in the official product documentation from Johnson Controls. Please retain your proof of purchase for warranty claims. For detailed warranty terms and conditions, refer to the official Johnson Controls webwebgunean edo jarri harremanetan bere bezeroarentzako zerbitzuarekin.

8. Bezeroarentzako arreta

For technical assistance, product inquiries, or support, please contact Johnson Controls directly. Their official website usually provides contact information for customer service and technical support departments.

  • Visit the official Johnson Controls website for the latest support resources.
  • Have your product model number (TE-6100-2) and any relevant system information ready when contacting support.

Erlazionatutako dokumentuak - TE-6100-2

Aurreview TE-7710-100 eta TE-7720-100 RF haririk gabeko seinalearen indarraren gunearen azterketa tresnen instalazio gida
Johnson Controls TE-7710-100 eta TE-7720-100 RF haririk gabeko seinalearen indarraren gune-inkesta tresnen instalazio-argibideak eta gida, TE-7700 serieko RF haririk gabeko gela-tenperatura neurtzeko sistemaren aplikazioa, muntaketa, konfigurazioa, seinale-egiaztapena eta zehaztapen teknikoak zehaztuz.
Aurreview Johnson Controls A421 Serieko Tenperatura Kontrol Elektronikoak Ziklotik Kanpoko Desizoztearekin Instalazio Argibideak
Johnson Controls PENN A421 Serieko Tenperatura Kontrol Elektronikoen instalazio gida osoa, ziklotik kanpoko desizozte funtzionalitatea duena. Produktua hartzen du barne.view, aplikazioak, neurriak, muntaketa, kableatua, konfigurazioa, doikuntzak, arazoak konpontzea eta zehaztapen teknikoak.
Aurreview Hx 3 ukipen-pantailako termostatoaren erabiltzailearen informazio eskuliburua
Erabiltzailearen informazio eskuliburu honek Johnson Controls Hx 3 ukipen-pantailako termostatoari (modeloa: S1-THXU430W) buruzko argibide eta gida zehatzak eskaintzen ditu, instalazioa, ezaugarriak, funtzionamendua, aplikazioen konexioa eta ezarpenak jorratzen dituena.
Aurreview TEC3000 Series On/Off or Floating Fan Coil Thermostats Quick Start Guide
This Quick Start Guide provides essential information for installing, configuring, and troubleshooting the Johnson Controls TEC3000 Series On/Off or Floating Fan Coil Thermostats. It covers emissions compliance, installation steps, wiring diagrams, setup procedures, and technical specifications.
Aurreview Johnson Controls FCP Largo Termostatoaren Erabiltzailearen Gida: FCP-NA-701-L eta FCP-PA-701-L
Johnson Controls FCP-NA-701-L eta FCP-PA-701-L Largo termostatoen erabiltzailearen gida osoa. Fan coil eta PTAC sistemen ezaugarriak, instalazioa, konfigurazioa, funtzionamendua, ezarpen aurreratuak, arazoak konpontzea eta zehaztapen teknikoak biltzen ditu.
Aurreview Johnson Controls Metasys VAV Controller Technical Manual (636.3)
This technical manual (636.3) for the Johnson Controls Metasys Variable Air Volume (VAV) Controller provides comprehensive guidance for advanced HVAC system control. It details installation, configuration, wiring, networking, and troubleshooting for optimal air volume management in commercial and industrial environments.