Fluke 28IIEX/ETL

Fluke 28IIEX/ETL Intrinsically Safe True-RMS Digital Multimeter User Manual

1. Sarrera

This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of the Fluke 28IIEX/ETL Intrinsically Safe True-RMS Digital Multimeter. This device is engineered for precise electrical measurements in potentially hazardous environments, offering robust performance and advanced safety features.

2. Segurtasun informazioa

WARNING: Read and understand all safety information before using this product. Failure to do so may result in serious injury or death.

2.1 Segurtasun Jarraibide Orokorrak

  • Always use the multimeter with the specified test leads and accessories.
  • Ez erabili multimetroa hondatuta badago edo arraro funtzionatzen badu.
  • Bete tokiko eta nazioko segurtasun-kode guztiak.
  • Neurketak egin aurretik, ziurtatu funtzio eta tarte zuzenak hautatuta daudela.
  • Avoid working alone in hazardous environments.

2.2 Berez Segurtasuneko Funtzionamendua

The Fluke 28IIEX/ETL is designed for use in hazardous locations classified as:

  • ATEX: II 2 G Ex ia IIC T4 Gb, II 2 D Ex ia IIIC T130°C Db, I M1 Ex ia I Ma
  • NEC-500: Class I, Div 1, Groups A-D, 130 °C
  • IEXEx: Ex ia IIC T4 Gb, Ex ia IIIC T130°C Db, Ex ia I Ma

These ratings ensure the device will not ignite explosive atmospheres under normal or fault conditions. Always ensure the device is used within its specified environmental and electrical limits for intrinsically safe operation.

2.3 Electrical Safety Ratings

The multimeter meets International Electrotechnical Commission (IEC) safety standard 61010 and is certified for:

  • Category III 1000V: For measurements on building circuit installations (e.g., service panel parts, branch circuits, fixed installations).
  • Category IV 600V: For measurements at the origin of the installation (e.g., electricity meters, primary over-current protection equipment).
  • Kutsadura 2. maila: Barruko erabilerarako.

2.4 Ingurumena babestea

The device is Ingress Protection (IP) certified IP67, meaning it is waterproof, dust-proof, and drop-proof, suitable for harsh industrial environments.

3. Produktua amaitu daview

The Fluke 28IIEX/ETL is a robust digital multimeter designed for reliability and accuracy. It features a large LCD display with a two-level bright white backlight for visibility in various lighting conditions.

Fluke 28IIEX/ETL Intrinsically Safe True-RMS Digital Multimeter

1. irudia: Aurrealdea view of the Fluke 28IIEX/ETL Digital Multimeter. The image displays the device with its red protective holster, gray body, LCD screen showing '28.20 V AC', and the rotary dial for function selection. Below the dial are the input jacks for current, voltage, and common connections, along with safety warnings and certifications.

3.1 Ezaugarri nagusiak

  • True-RMS measurements for accurate readings on linear and non-linear loads.
  • Auto- and manual-ranging capabilities.
  • Neurriak voltage, current, resistance, capacitance, frequency, temperature, conductance, and duty cycle.
  • Performs continuity and diode tests.
  • Low-pass filter for accurate voltage and frequency measurements on variable-speed motor drives.
  • MIN/MAX/AVG and Peak Capture functions to record transients and measurement variations.
  • Relative mode to remove test lead interference.
  • Backlit keypad buttons and display for low-light conditions.
  • Audible alarm for incorrect test lead connection.

4. Konfigurazioa

4.1 Bateriaren instalazioa

The Fluke 28IIEX/ETL requires four (4) AA alkaline batteries for operation. To install or replace batteries:

  1. Ziurtatu multimetroa itzalita dagoela.
  2. Kendu gomazko babes-zorroa.
  3. Locate and open the battery compartment cover on the rear of the device.
  4. Insert four new AA alkaline batteries, observing the correct polarity markings.
  5. Securely close the battery compartment cover and reattach the holster.

4.2 Proba-kableak konektatzea

Always connect test leads to the appropriate input jacks for the measurement being performed. The multimeter will sound an alarm if leads are connected incorrectly for the selected function.

  • COM Jack: Connect the black test lead to the common (COM) jack for all measurements.
  • VΩHz Jack: Konektatu proba-kable gorria entxufe honetara bolumenaren arabera.tage, resistance, frequency, capacitance, and diode tests.
  • mAµA Jack: Connect the red test lead to this jack for current measurements up to 400mA. This input is fused.
  • 10A Max Fused Jack: Konektatu proba-kable gorria entxufe honetara 10A-rainoko korronte-neurketak egiteko. Sarrera hau fusible batekin hornituta dago.

5. Funtzionamendu-argibideak

Turn the rotary switch to the desired function. The multimeter defaults to auto-ranging mode, automatically selecting the correct measurement range. Press the 'RANGE' button to switch to manual ranging.

5.1 Neurketa Voltage (AC/DC)

  1. Connect the black lead to COM and the red lead to VΩHz.
  2. Turn the rotary switch to V~ (AC Voltage) edo V- (DC bolumenatageta).
  3. Konektatu proba-kableak neurtu beharreko zirkuituan edo osagaian.

5.2 Measuring Current (mA/A/µA)

WARNING: Never attempt to measure current by connecting the multimeter in parallel with a voltage source. This can damage the meter and cause injury.

  1. Connect the black lead to COM. Connect the red lead to mAµA for small currents or 10A Max Fused for larger currents.
  2. Turn the rotary switch to mA/A~ (AC Current) or mA/A- (DC Current).
  3. Ireki zirkuitua eta konektatu multimetroa kargarekin seriean.

5.3 Erresistentzia neurtzea (Ω)

  1. Connect the black lead to COM and the red lead to VΩHz.
  2. Turn the rotary switch to Ω.
  3. Ensure the circuit is de-energized. Connect the test leads across the component.

5.4 Jarraitasun proba

  1. Connect the black lead to COM and the red lead to VΩHz.
  2. Turn the rotary switch to the continuity symbol (speaker icon).
  3. Ensure the circuit is de-energized. Connect the test leads across the component. An audible tone indicates continuity.

5.5 Diodoaren proba

  1. Connect the black lead to COM and the red lead to VΩHz.
  2. Turn the rotary switch to the diode symbol.
  3. Ensure the circuit is de-energized. Connect the test leads across the diode. The display shows the forward voltage tanta.

5.6 Kapazitantzia neurtzea (F)

  1. Connect the black lead to COM and the red lead to VΩHz.
  2. Turn the rotary switch to the capacitance symbol.
  3. Ensure the capacitor is discharged before connecting the test leads.

5.7 Measuring Frequency (Hz) and Duty Cycle (%)

  1. Connect the black lead to COM and the red lead to VΩHz.
  2. Turn the rotary switch to Hz.
  3. Connect the test leads across the signal source. Press the '%' button to view lan zikloa.

5.8 Measuring Temperature (°C/°F)

  1. Connect the K-type thermocouple (included) to the VΩHz and COM jacks, observing polarity.
  2. Turn the rotary switch to the temperature symbol.
  3. Place the thermocouple tip on the object to be measured.

5.9 Funtzio bereziak

  • MIN MAX: Press to record minimum, maximum, and average readings over time.
  • PEAK MIN MAX: Captures fast transients.
  • REL Δ (Modu erlatiboa): Subtracts the stored reading from subsequent readings, useful for nulling out test lead resistance.
  • EUTSI: Uneko pantailaren irakurketa izozten du.

6. Mantentzea

6.1 Garbiketa

Garbitu kasua iragarkiarekinamp oihal eta detergente leun bat. Ez erabili urratzailerik edo disolbatzailerik. Ziurtatu gailua lehor dagoela erabili aurretik.

6.2 Bateria ordezkatzea

Ikusi 4.1 atala bateria ordezkatzeko argibideak ikusteko. Ordeztu bateriak bateria baxuaren adierazlea pantailan agertzen denean.

6.3 Fusiblearen ordezkapena

WARNING: To prevent injury or damage to the multimeter, use only specified replacement fuses with the correct amparoa, liburukiatage, eta eten balorazioak.

The Fluke 28IIEX/ETL has two internal fuses:

  • 10A Max Fused: For the 10A current input.
  • 400mA Fused: For the mA/µA current input.

Fuse replacement should only be performed by qualified personnel. Consult the full service manual or contact Fluke customer support for detailed instructions.

7. Arazoak

If the multimeter is not functioning as expected, review honako arazo ohiko hauek:

  • Ez dago pantailarik edo pantaila ahula: Egiaztatu bateriak eta ordeztu behar izanez gero.
  • Irakurketa okerrak: Ensure test leads are correctly connected, the function and range are appropriate for the measurement, and the circuit is de-energized for resistance/continuity/diode tests.
  • Korrontearen neurketak ez du funtzionatzen: Check the fuses for the respective current input (10A or 400mA). Replace if blown.
  • Multimeter does not respond: Turn the unit off and then on again. If the issue persists, remove batteries for a few minutes and reinsert.

For persistent issues or complex problems, contact Fluke customer support.

8. Zehaztapenak

ParametroaZehaztapena
Maximum AC/DC Current Input10 A
Maximum AC/DC Voltage Sarrera1000 V
Maximum Resistance Detected50 MΩ
Gehienezko Maiztasuna199.99 kHz
Kapazitate maximoa9999 µF
Temperature Range (excluding probe)-200 eta +1090 °C artean / -328 eta +1994 °F artean
Duty Cycle Range%0etik 99.9era
BistaratzeaLCD with 20,000-count resolution, two-level backlight
Elikatze Hornidura4 AA batteries (Alkaline)
Segurtasun balorazioakATEX, NEC-500, IEXEx, IEC 61010, CAT III 1000V, CAT IV 600V, Pollution Degree 2
Sarrera babesaIP67 (Waterproof, Dust-proof, Drop-proof)
Pisua2.85 lb (1.29 kg)
Neurriak (L x W x H)9.7 x 6.3 x 3.36 hazbete (24.6 x 16.0 x 8.5 cm)

9. Bermea eta Laguntza

Fluke Corporation products are designed for reliability and performance. For warranty information, technical support, or service, please visit the official Fluke website or contact your local Fluke representative.

Official Fluke Webgunea: www.fluke.com

Erlazionatutako dokumentuak - 28IIEX/ETL

Aurreview Fluke 110 True-RMS multimetroa: zehaztapen teknikoak eta ezaugarriak
Fluke 110 True-RMS multimetro trinkoaren zehaztapen eta ezaugarri zehatzak, instalazio elektriko zehatzerako eta arazoak konpontzeko diseinatua. Zehaztasuna, segurtasun-balorazioak eta barne hartzen dituen osagarriak barne hartzen ditu.
Aurreview Fluke 116 True-rms Multimeter: Quick Reference Guide
Quick reference guide for the Fluke 116 True-rms Multimeter, detailing its functions, measurement capabilities, and usage for electrical testing.
Aurreview Fluke 179 Multimetro Digitala: Mantentze-lanen eta Zerbitzuaren Gida
Ezagutu Fluke 179 True-rms multimetro digitala, mantentze elektriko eta HVAC eraginkorrerako diseinatua. Ikasi bere ezaugarriak, zehaztapenak eta gomendatutako osagarriak landa-zerbitzu fidagarria lortzeko.
Aurreview Fluke 323/324/325 Clamp Multimetroaren erabiltzailearen eskuliburua
Fluke 323, 324 eta 325 cl-rako erabiltzailearen eskuliburu osoaamp metroak, ezaugarrien xehetasunak, segurtasun neurriak, zehaztapenak eta neurketa elektriko zehatzak egiteko funtzionamendu-jarraibideak.
Aurreview Fluke 114, 115, 116, 117 Digital Multimeters: User Manual and Specifications
Detailed specifications, features, and user guide for Fluke 114, 115, 116, and 117 True-rms Digital Multimeters, covering safety, operation, maintenance, and technical data.
Aurreview Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters - Technical Data
Detailed technical specifications, features, and ordering information for the Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters, including models 374 FC, 375 FC, and 376 FC. Covers measurement capabilities, comparison charts, and the Fluke Connect system.