Dwyer WMT2-B-C-11-1

Dwyer WMT2-BC-11-1 Irteera Pultsatuko Ur-neurgailu Multi-Jet Erabiltzailearen Eskuliburua

1. Produktua amaitu daview

The Dwyer Series WMT2 Multi-Jet Water Meter is engineered for commercial and industrial applications requiring accurate water flow measurement. Its multi-jet design ensures reliable performance and accuracy across a broad range of flow rates, including low-flow conditions. The meter is built for durability and minimal maintenance, even in challenging environments. It features a magnetically driven, hermetically sealed register that prevents leaks and fogging, completely isolating it from the water flow. A reed switch, activated by a magnet on the dial, generates a pulsed output directly proportional to the flow rate. This output is suitable for remote monitoring of flow rate or totalization and can be integrated with PLCs, counters, data loggers, and SCADA systems.

Dwyer WMT2-B-C-11-1 Multi-Jet Water Meter with Pulsed Output

Image 1.1: The Dwyer WMT2-B-C-11-1 Multi-Jet Water Meter, showing its brass body, blue casing, and the meter face with a pulsed output connection.

2. Segurtasun informazioa

WARNING: This product is NOT FOR POTABLE WATER USE. The brass construction contains lead in excess of low-lead limits. Do not use this meter in applications where water will be consumed by humans or animals.

Always ensure proper installation by qualified personnel to prevent leaks and ensure accurate operation. Adhere to all local codes and regulations regarding plumbing and electrical connections.

3. Produktuaren ezaugarriak

  • Multi-Jet Design: Provides high accuracy and wide flow range capabilities.
  • Pulsed Output: Equipped with a reed switch for remote monitoring and integration with control systems.
  • Hermetically Sealed Register: Magnetically driven, preventing leaks and fogging for clear readings.
  • Eraikuntza iraunkorra: Designed for long service life in commercial and industrial settings.
  • Letoizko gorputza: Robust construction for demanding applications.

4. Zehaztapenak

ZehaztapenaBalioa
EreduaWMT2-B-C-11-1
Akoplamenduaren Tamaina1" BSPT
Gehienezko Emaria7 m³/h
Emaria Nominala0.25 eta 3.5 m³/h
Transitional Flow Rate0.07 m³/h
Pultsu-tasa1 gallon per pulse
Tenperatura maximoa104 °F (40 °C)
Presio maximoa232 psi (16 bar)
Konexio elektrikoakColor-coded lead wires, 4.5' (1.5 m) long
Elementuaren pisua13.52 kilo
FabrikatzaileaDwyer Instruments, Inc.

5. Konfigurazioa eta instalazioa

Installation of the Dwyer WMT2-B-C-11-1 water meter should be performed by a qualified professional in accordance with all applicable local and national plumbing and electrical codes.

  1. Kokapena aukeratzea: Choose a location that is easily accessible for reading and maintenance, protected from freezing temperatures, and where the meter can be installed horizontally with the flow arrow pointing in the direction of water flow.
  2. Hodien prestaketa: Ensure the piping is clean and free of debris before installation. Use appropriate pipe thread sealant on the 1" BSPT couplings.
  3. Instalazio mekanikoa: Install the meter into the pipeline, ensuring a tight, leak-free connection. The meter should be installed in a straight run of pipe, ideally with at least 10 pipe diameters of straight pipe upstream and 5 pipe diameters downstream for optimal accuracy.
  4. Konexio elektrikoa: Connect the color-coded lead wires from the pulsed output to your remote monitoring system (PLC, counter, data logger, SCADA). Refer to your system's documentation for specific wiring requirements. Ensure all electrical connections are secure and properly insulated.
  5. Ihesak egiaztatzea: After installation, slowly open the water supply to the meter and check for any leaks at the connections.

6. Funtzionamendu-argibideak

Once installed and the water supply is restored, the Dwyer WMT2-B-C-11-1 meter will begin measuring water flow. The meter's register displays the totalized volume of water that has passed through it. The pulsed output provides an electrical signal (1 pulse per gallon) that can be used by external devices for remote monitoring and data logging.

  • Reading the Meter: The main display on the meter face shows the total accumulated volume. Smaller dials may indicate fractional units for more precise readings.
  • Pulsed Output: The reed switch generates a pulse for every gallon of water that flows through the meter. Connect the lead wires to a compatible device (e.g., PLC, counter) to record these pulses and calculate flow rate or total volume remotely.
  • Fluxuaren Norabidea: Ensure water flows in the direction indicated by the arrow on the meter body for accurate measurement.

7. Mantentzea

The Dwyer WMT2-B-C-11-1 Multi-Jet Water Meter is designed for relatively maintenance-free operation. However, periodic checks are recommended to ensure continued accuracy and performance:

  • Ikus-ikuskapena: Regularly inspect the meter for any signs of physical damage, leaks, or corrosion.
  • Register Clarity: Ensure the hermetically sealed register remains clear and free of fogging, allowing for easy reading.
  • Konexioaren Osotasuna: Verify that all plumbing and electrical connections remain secure and free of corrosion.
  • Garbiketa: If the exterior of the meter becomes dirty, wipe it with a damp oihal. Ez erabili produktu kimiko gogorrak edo garbitzaile urratzaileak.

No internal user-serviceable parts are present. Do not attempt to disassemble the meter, as this will void the warranty and may damage the device.

8. Arazoak

If you encounter issues with your Dwyer WMT2-B-C-11-1 water meter, consider the following troubleshooting steps:

  • No Flow Reading:
    • Check if water is actually flowing through the pipe.
    • Verify the meter is installed with the flow arrow in the correct direction.
    • Inspect for any blockages upstream or downstream of the meter.
  • Irakurketa okerrak:
    • Ensure the meter is installed horizontally.
    • Check for air in the pipeline, which can affect accuracy.
    • Verify that the flow rate is within the meter's specified nominal flow range.
  • No Pulsed Output:
    • Confirm that water is flowing through the meter and the mechanical register is advancing.
    • Check the electrical connections of the lead wires to your monitoring device.
    • Ensure the monitoring device is correctly configured to receive pulses.
  • Konexioetako ihesak:
    • Tighten connections carefully, ensuring not to overtighten.
    • If necessary, drain the system, reapply pipe thread sealant, and reassemble.

If problems persist after performing these checks, contact Dwyer Instruments, Inc. technical support for assistance.

9. Bermea eta Laguntza

For information regarding the product warranty, technical support, or replacement parts, please contact Dwyer Instruments, Inc. directly or visit their official website. Keep your purchase receipt and product model number (WMT2-B-C-11-1) readily available when seeking support.

Erlazionatutako dokumentuak - WMT2-B-C-11-1

Aurreview Dwyer Serieko 477AV Eskuko Manometro Digitala: Zehaztapenak, Instalazioa eta Funtzionamendu Argibideak
Dwyer Series 477AV Eskuko Manometro Digitalaren gida osoa, presio, emari eta abiadura neurketen zehaztapenak, instalazioa, funtzionamendu argibideak, ezaugarriak eta mantentze-lanak biltzen dituena.
Aurreview Dwyer Serieko IEF Txertatze Fluxu Elektromagnetikoko Transmisoreak: Instalazio eta Funtzionamendu Argibideak
Dokumentu honek Dwyer Serieko IEF Txertatze Fluxu Elektromagnetikoko Transmisorearen zehaztapen osoak, instalazio gida eta funtzionamendu argibideak eskaintzen ditu, eta haren ezaugarriak, aplikazioak eta fluido industrialen abiadura neurtzeko komunikazio protokoloak zehaztu ditu.
Aurreview Dwyer Fluxu Neurketa eta Kontrol Produktuak: Aukeraketa Gida Osoa
Explore Dwyer Instruments' extensive range of flowmeters, flow switches, and flow transmitters. This guide provides detailed specifications and selection criteria to help identify the optimal product for your industrial or commercial application.
Aurreview Dwyer Serieko VFC Visi-Float Fluxu-neurgailuen Hasiera Azkarreko Gida
Dwyer Serieko VFC Visi-Float emari-neurgailuentzako hasiera azkarreko gida, instalazio, muntaketa eta irakurketa argibide garrantzitsuak eta funtzionamendu-abisu garrantzitsuekin batera.
Aurreview Dwyer Serieko TUF Energia Neurgailu Ultrasonikoak: Fluxuaren eta Tenperaturaren Monitorizazioa
Dwyer Serieko TUF Energia Neurgailu Ultrasonikoen zehaztapen, ezaugarri, aplikazio eta eskaera-informazio zehatza, Modbus® edo BACnet komunikazioarekin emaria eta tenperatura zehatz-mehatz monitorizatzeko diseinatua.
Aurreview Dwyer Prozesuen Automatizazioko Produktuen Aplikazioak eta Hautaketa Gidak
Arakatu Dwyer Instrumentsen prozesuen automatizaziorako gida osoa, HVAC, uraren tratamendua, petrolioa eta gasa eta gehiagorako produktuen aplikazioak eta hautaketa biltzen dituena. Ezagutu presio, fluxu, maila, tenperatura eta airearen kalitaterako instrumentazio-irtenbideak.