Legrand 042786

Legrand 042786 Isolation Transformer User Manual

Eredua: 042786 | Marka: Legrand

1. Sarrera

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Legrand 042786 single-phase isolation transformer. This device is designed to provide electrical isolation between primary and secondary circuits, enhancing safety and protecting sensitive equipment from power fluctuations. Please read this manual thoroughly before installation and use to ensure safe and efficient operation.

2. Segurtasun-argibideak

Adherence to the following safety guidelines is crucial for preventing injury and damage to the equipment:

  • Pertsonal kualifikatua soilik: Installation and maintenance must be performed by qualified electricians in accordance with local and national electrical codes.
  • Potentzia deskonexioa: Always disconnect power to the primary circuit before performing any installation, wiring, or maintenance tasks. Verify zero voltage with appropriate testing equipment.
  • Lurreratze egokia: Ensure the transformer and associated equipment are properly grounded as per electrical standards.
  • Aireztapena: Install the transformer in a well-ventilated area to prevent overheating. Do not obstruct ventilation openings.
  • Ingurumen-baldintzak: Avoid installing the transformer in environments with excessive moisture, dust, corrosive gases, or extreme temperatures.
  • Gainkarga babesa: Ensure appropriate overcurrent protection devices (fuses or circuit breakers) are installed on both primary and secondary circuits, sized according to the transformer's ratings.
  • Terminal konexioak: Ensure all screw terminal connections are tight and secure to prevent loose connections, which can cause overheating or arcing.

3. Produktua amaitu daview

3.1 Ezaugarriak

  • Single-phase isolation transformer.
  • Lehen liburuatage options: 230V and 400V.
  • Bigarren mailako liburukiatage options: 115V and 230V (derived from 2 x 115V windings).
  • Output power: 63 VA.
  • Connection via robust screw terminals.
  • Designed for panel mounting.
  • Complies with international standards EN 61131-2, EN 60204-1, and EN 61439-1.

3.2 Osagaiak

The Legrand 042786 isolation transformer consists of a core and windings encased in a protective housing, featuring clearly marked screw terminals for primary and secondary connections. The unit is designed for secure panel mounting.

Legrand Isolation Transformer with screw terminals

1. irudia: Illustrative image of a Legrand isolation transformer. Please note that this image displays model 42789 with a 220VA rating, which is similar in appearance but differs in model number and power rating from the 042786 (63VA) model described in this manual. The image shows the primary input terminals (230V, 400V) and secondary output terminals (115V, 230V) with screw connections.

4. Zehaztapenak

ParametroaBalioa
Modelo zenbakia042786
MarkaLegrand
MotaSingle-phase Isolation Transformer
Lehen mailako liburukiatage230V / 400V
Bigarren mailako liburukiatage2 x 115V (configurable for 115V or 230V)
Irteera Potentzia63 VA
Konexio motaTorloju terminalak
Muntatze MotaPanelaren muntaketa
Neurriak (L x W x H)33 x 26.5 x 15 cm
Pisua959 gramo
Bolumena3.82 dm³
Arauak betetzeaEN 61131-2, EN 60204-1, EN 61439-1

5. Instalazioa (Konfigurazioa)

Before beginning installation, ensure all safety instructions (Section 2) are thoroughly understood and followed.

5.1 Muntaketa

  1. Select a suitable location within an electrical panel or enclosure that provides adequate ventilation and protection from environmental hazards.
  2. Ensure the mounting surface is robust enough to support the transformer's weight (approximately 959 grams).
  3. Secure the transformer to the panel using appropriate fasteners through the designated mounting points.

5.2 Kableatua

The transformer features clearly labeled screw terminals for primary and secondary connections. Refer to the wiring diagram provided with the product or on the unit itself for precise connections. The image in Section 3.2 provides a visual reference for terminal layout.

  • Primary Connection (Input): Connect the incoming power supply to the primary terminals. The transformer supports 230V and 400V primary inputs. Ensure the correct terminals are used for your supply voltage.
  • Secondary Connection (Output): Connect your load to the secondary terminals. The transformer provides 2 x 115V windings, which can be configured for either 115V or 230V output, depending on your application requirements. Consult the wiring diagram for series or parallel connections to achieve the desired secondary voltage.
  • Lurreratzea: Connect the protective earth (ground) conductor to the designated grounding terminal on the transformer.
  • Terminalen estutzea: After connecting all wires, ensure all screw terminals are tightened to the recommended torque to prevent loose connections.

6. Funtzionamendua

Once properly installed and wired, the Legrand 042786 isolation transformer operates automatically upon application of primary voltage. It provides a stable, isolated secondary voltage to the connected load.

  • Hasierako piztea: After completing installation and verifying all connections, apply power to the primary circuit.
  • Jarraipena: Periodically check the transformer for any unusual noises, excessive heat, or odors, which may indicate a problem.
  • Karga kudeaketa: Ensure the connected load does not exceed the transformer's 63 VA output power rating to prevent overheating and potential damage.

7. Mantentzea

The Legrand 042786 isolation transformer is designed for minimal maintenance. However, regular inspections can help ensure its longevity and reliable operation.

  • Aldizkako ikuskapena: At regular intervals (e.g., annually), inspect the transformer for dust accumulation, loose connections, or signs of physical damage.
  • Garbiketa: Disconnect power before cleaning. Use a dry, soft cloth or compressed air to remove dust from the transformer's surfaces and ventilation openings. Do not use liquid cleaners.
  • Terminalaren egiaztapena: With power disconnected, periodically re-tighten terminal screws to ensure secure electrical connections.
  • Ingurumen-kontrola: Ensure the operating environment remains within the specified conditions (temperature, humidity).

8. Arazoak

If the transformer is not functioning as expected, consider the following common issues before contacting support:

  • Irteerarik ez Voltage:
    • Check if primary power is supplied and active.
    • Verify primary and secondary wiring connections are correct and secure.
    • Check for tripped circuit breakers or blown fuses in both primary and secondary circuits.
  • Gehiegizko berotzea:
    • Ensure the transformer is not overloaded (load current exceeds 63 VA rating).
    • Check for adequate ventilation around the transformer.
    • Verify ambient temperature is within acceptable limits.
  • Ezohiko zarata:
    • Ensure all mounting hardware is tight.
    • Check for loose internal components (if accessible and safe to do so after disconnecting power).

If troubleshooting steps do not resolve the issue, contact Legrand technical support or a qualified service professional.

9. Standards and Compliance

The Legrand 042786 isolation transformer is designed and manufactured to comply with the following international standards:

  • EN 61131-2: Programmable controllers - Part 2: Equipment requirements and tests.
  • EN 60204-1: Safety of machinery - Electrical equipment of machines - Part 1: General requirements.
  • EN 61439-1: Volumen baxuatage switchgear and controlgear assemblies - Part 1: General rules.

Compliance with these standards ensures the product meets stringent safety and performance criteria for industrial electrical applications.

10. Bermea eta Laguntza

Legrand products are manufactured to high-quality standards and are typically covered by a manufacturer's warranty against defects in materials and workmanship. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or visit the official Legrand webgunea.

For technical assistance, product inquiries, or to report a problem, please contact Legrand customer support through their official channels. When contacting support, please have your product model number (042786) and purchase details readily available.

Legrand Ofiziala Webgunea: www.legrand.com

Erlazionatutako dokumentuak - 042786

Aurreview Legrand 4 120 69 Fase bakarreko MID energia-neurgailua: zehaztapenak, instalazioa eta adierazpena
Legrand 4 120 69 fase bakarreko MID ziurtagiridun energia-neurgailu bat da, 45A-rainoko konexio zuzenerako diseinatua. Dokumentu honek funtsezko zehaztapen teknikoak, instalazio-jarraibideak, segurtasun-abisuak eta EBko Adostasun Adierazpena eskaintzen ditu.
Aurreview Legrand ALB2212WH Bi norabideko etengailua adierazle-argiarekin - Instalazio gida
Legrand ALB2212WH gainazaleko bi norabideko etengailuaren informazioa eta instalazio gida, adierazle-argi integratua duena. Zehaztapen teknikoak, kableatuak eta muntatzeko argibideak zehazten ditu.
Aurreview Legrand 4 120 40/4 120 41 EMDX³ Energia Kontagailuaren Ezaugarri Teknikoak eta Kableatu Gida
Legrand 4 120 40 eta 4 120 41 EMDX³ hiru faseko energia-neurgailuen zehaztapen tekniko zehatzak, instalazio-argibideak eta kableatu-diagramak. RS485 Modbus konexioa eta segurtasun-jarraibideak barne hartzen ditu.
Aurreview Legrand 2 bideko argiztatutako etengailua (gainazaleko muntaketa) - ALB2211WH modeloa instalazio gida
Legrand ALB2211WH gainazalean muntatutako bi norabideko etengailu argiztatuaren instalazio gida eta zehaztapen teknikoak. Konexio erraza, 2300W-ko gehienezko ahalmena eta iluntasunean ikusteko adierazle-argia barne hartzen ditu.
Aurreview Legrand 310332 19-inch Rack PDU with Integrated UPS: Safety Information and Operation Guide
Comprehensive safety information, installation, operation, and disposal guidelines for the Legrand 310332 19-inch rack PDU with an integrated 800 VA / 480 W UPS, featuring 8 Schuko outlets.
Aurreview Legrand Konektatutako Hiru Faseko Energia Kontagailuaren 4 121 75 Instalazio Gida
Legrand-en hiru faseko energia-neurgailu konektatuaren instalazio eta konexio gida osoa (4 121 75 modeloa). Kableatu-diagramak, segurtasun-neurriak, aplikazioen integrazioa eta EBko adostasunari buruzko informazioa barne hartzen ditu.