QuietWarmth THERMST-D Non-Programmable Thermostat User Manual

For 120V or 240V Radiant Heat Systems

1. Sarrera

The QuietWarmth THERMST-D Non-Programmable Thermostat is designed to provide reliable control for 120V or 240V electric radiant floor heating systems. This thermostat offers flexible temperature management, allowing you to configure it for control based on floor temperature, room temperature, or a combination of room temperature with a floor temperature limit. It features a built-in Ground Fault Circuit Interrupter (GFCI) for enhanced safety and a clear, backlit display for easy monitoring and operation. A floor sensor is included to ensure accurate temperature readings and optimal comfort.

Aurrealdea view of the QuietWarmth THERMST-D Non-Programmable Thermostat, showing the digital display and control buttons.

1. irudia: Aurrealdea view of the THERMST-D Thermostat.

2. Segurtasun informazioa

Please read all instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or property damage.

  • OHARRA: To reduce the risk of electric shock, do not connect this device to a circuit with any phase operating down more than 150 volts to ground.
  • Instalazioa elektrizista kualifikatu batek egin behar du, tokiko eta estatuko araudi elektrikoen arabera.
  • The thermostat requires connection to a dedicated 20 Amp Zirkuitu.
  • The resistive load connected to the thermostat must not exceed 15 Amps.
  • Electric radiant floor heating systems are required by the National Electrical Code to be protected by a Ground Fault Circuit Interrupter (GFCI). This thermostat has a built-in GFCI.
  • Always turn off power at the circuit breaker before installing or servicing the thermostat.
Aldea view of the QuietWarmth THERMST-D Thermostat showing a warning label regarding electric shock risk.

2. irudia: Aldea view of the thermostat with safety warning label.

3. Paketearen edukia

Egiaztatu elementu guztiak paketean daudela:

  • QuietWarmth THERMST-D Non-Programmable Thermostat
  • Zoruaren sentsorea

4. Produktua amaitu daview

4.1 Ezaugarri nagusiak

  • Non-Programmable operation for radiant floor heat systems.
  • Compatible with both 120V and 240V heating systems.
  • Integrated Ground Fault Circuit Interrupter (GFCI) for safety.
  • Clear, backlit LED display for easy reading.
  • Includes a floor sensor for precise temperature control.
  • Configurable for floor temperature, room temperature, or room temperature with a floor temperature limit.
  • Seven-day energy log to monitor power consumption.
  • Supports multiple QuietWarmth mats: up to 120 sq ft for 120V systems, or 240 sq ft for 240V systems.

4.2 Osagaiak

The thermostat consists of a front display unit with control buttons and a back plate for electrical connections.

  • Aurrealdeko panela: Features a digital display showing time and temperature, along with 'Up', 'OK', and 'Down' buttons for navigation and setting adjustments.
  • Atzeko panela: Contains wiring terminals for power input (L1, L2) and load output, as well as a connection point for the floor sensor.
Itzuli view of the QuietWarmth THERMST-D Thermostat showing wiring terminals labeled L1(L), L2(N), and Load, along with a mounting screw.

3. irudia: Atzealdea view termostatoaren kableatu-terminalekin.

Image of the QuietWarmth floor sensor, a black cable with a small probe at the end.

Figure 4: Included floor sensor.

5. Konfigurazioa eta instalazioa

Instalazioa elektrizista kualifikatu batek bakarrik egin behar du.

5.1 Muntaketa

  • The thermostat is designed for wall mounting.
  • Ensure the mounting location is free from direct sunlight, drafts, or other heat sources that could affect temperature readings.

5.2 Kableatua

Before wiring, ensure power is OFF at the circuit breaker.

  1. Connect the thermostat to a dedicated 20 Amp Zirkuitu.
  2. Identify the Line (power supply) and Load (heating mat) wires.
  3. Connect the Line wires to the L1(L) and L2(N) terminals on the thermostat's back panel.
  4. Connect the Load wires from the heating mat to the 'Load' terminals on the thermostat.
  5. Ziurtatu lurreratze egokia tokiko araudi elektrikoen arabera.
  6. The thermostat is dual-voltage; it can be used with either 120V or 240V heating mats, but not simultaneously. Verify your heating mat's voltage bat dator elikadura-iturria.

5.3 Floor Sensor Placement

The floor sensor is crucial for accurate floor temperature control.

  • Place the sensor next to the long edge of the QuietWarmth heating mat.
  • Ensure the sensor is positioned in the heated area and not near any unheated zones or external heat sources.
  • Route the sensor wire carefully to avoid damage during installation of flooring materials.
An illustration showing a golden retriever dog sleeping on a floor with radiant heat film installed underneath, indicating warmth for floating floors.

5. irudia: Adibample of radiant heat film installation under floating floors.

An illustration showing a French bulldog puppy sleeping on a floor with radiant heat film installed underneath, indicating warmth for tile and glued floors.

6. irudia: Adibample of radiant heat film installation under tile and glued floors.

6. Funtzionamendu-argibideak

6.1 Piztu

After installation, restore power at the circuit breaker. The thermostat display will illuminate.

6.2 Tenperatura ezartzea

  • Erabili Up eta Behera nahi duzun tenperatura doitzeko botoiak.
  • Sakatu OK botoia zure hautaketa berresteko.

6.3 Kontrol moduak

The thermostat can be configured to operate in one of three control modes:

  • Floor Temperature Control: The thermostat maintains the floor at the set temperature using the floor sensor.
  • Gela-tenperatura kontrola: The thermostat maintains the room air temperature at the set point.
  • Room Temperature Control with Floor Limit: The thermostat primarily controls room air temperature but prevents the floor temperature from exceeding a specified maximum limit, protecting sensitive flooring materials.

Refer to the full installation guide for instructions on how to select and configure these control modes.

6.4 Energy Log

The thermostat features a seven-day energy log, allowing you to monitor the power consumption of your radiant heating system. Consult the detailed manual for accessing and interpreting this data.

7. Mantentzea

7.1 GFCI Testing

For continued safety, the built-in GFCI should be tested monthly.

  1. Sakatu PROBA button located on the bottom of the thermostat.
  2. The GFCI should trip, cutting power to the heating system and indicating a fault.
  3. Sakatu Berrezarri button to restore power.
  4. If the GFCI does not trip or reset correctly, discontinue use and contact a qualified electrician.
Behean view of the QuietWarmth THERMST-D Thermostat showing the GFCI test button and 'Test Monthly' text.

Figure 7: Bottom of the thermostat with GFCI test button.

7.2 Garbiketa

Garbitu termostatoaren kanpoaldea zapi leun eta lehor batekinamp oihal. Ez erabili garbitzaile edo disolbatzaile urratzailerik.

8. Arazoak

If you encounter issues with your QuietWarmth THERMST-D thermostat, refer to the following common problems and solutions:

  • Pantailarik ez/Energiarik ez:
    • Check the circuit breaker for the dedicated circuit and ensure it is in the ON position.
    • Egiaztatu kableatu-konexio guztiak ondo eta ondo daudela.
  • Heating System Not Activating:
    • Ensure the thermostat is set to a temperature higher than the current room or floor temperature.
    • Check if the GFCI has tripped (press the RESET button if it has).
    • Confirm the correct control mode is selected (floor, room, or room with limit).
  • GFCI Trips Frequently:
    • This indicates a ground fault. Immediately turn off power at the circuit breaker.
    • Inspect the heating mat and wiring for any damage or moisture.
    • Ensure the total resistive load does not exceed 15 Amps.
    • Contact a qualified electrician for diagnosis and repair.
  • Tenperatura-irakurketa okerrak:
    • Verify the floor sensor is correctly installed and not damaged.
    • Ensure the thermostat is not exposed to drafts, direct sunlight, or other external heat sources.

For issues not covered here, please contact QuietWarmth customer support or a qualified electrician.

9. Zehaztapenak

ZehaztapenaXehetasuna
MarkaQuietWarmth
Ereduaren izenaQuietWarmth Non-Programmable Thermostat
Zati zenbakiaTERMISTIKA-D
Produktuaren neurriak3" L x 4" W x 6" H
Elementuaren pisua11.4 ontza
KoloreaZuria
MaterialaPlastikoa
liburukiatage120 voltio, 240 voltio
Max Resistive Load15 Amps
Energia iturriaKableatua
Kontrolagailu motaSakatu botoia
Tenperatura Kontrol MotaEskuliburua
Bistaratzeko motaLED (Atzeko argiztapena)
Konektibitate TeknologiaKableatua
Ezaugarri BereziaEnergy Usage Tracking, Built-in GFCI
Muntatze MotaHormako Muntaia
Zehaztapena MetUL
UPC696087109103

10. Bermea eta Laguntza

10.1 Bermearen informazioa

The QuietWarmth THERMST-D Non-Programmable Thermostat comes with a 3-year limited warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims.

10.2 Bezeroarentzako laguntza

For technical assistance, troubleshooting, or warranty inquiries, please contact QuietWarmth customer support. Refer to the product packaging or the manufacturer's webuneko harremanetarako informazioa lortzeko gunea.

Erlazionatutako dokumentuak - TERMISTIKA-D

Aurreview QuietWarmth teila erradiaziozko bero-filmaren instalazio-gida
QuietWarmth Tile Radiant Heat Film-aren instalazio eskuliburu osoa, konfigurazio zehatza, konexio elektrikoak eta baldosa eta itsatsitako gainazaletarako zoru-integrazioa. Ikasi zure zoru-berogailu erradiatzaile sistema modu seguru eta eraginkorrean instalatzen.
Aurreview QuietWarmth Float Berogailu Erradiatzailearen Filmaren Instalazio Gida
QuietWarmth Float berogailu erradiatzaileko filmaren instalazio eskuliburu osoa, xehetasunen plangintza, instalazio elektrikoa, zoruaren azpiko prestaketa, alfonbraren instalazioa, probak eta arazoak konpontzea zoru-berotze eroso eta eraginkorra lortzeko.
Aurreview Azel D-508F Digital Radiant Floor Heating Thermostat Instruction Manual
Comprehensive instruction manual for the Azel Technologies D-508F digital non-programmable universal radiant floor heating thermostat. Learn about installation, operation modes (A, F, AF), temperature settings, wiring, error codes, and specifications.
Aurreview MP Global Products Radiant Heat Film Limited-en bermea eta erregistroa
Dokumentu honek MP Global Products-en bero-film erradiatzailearen berme mugatua azaltzen du, zoru flotatzaile edo baldosen azpian erabilia. Berme-aldia, estaldura, bazterketak eta erreklamazioa egiteko prozesua zehazten ditu. Sistemaren kontrol-zerrenda bat eta etxejabeek instalazioa egin ondoren betetzeko bermearen erregistro-inprimakia ere baditu.
Aurreview THERMAEGH Termostato Adimendunaren Erabiltzailearen Eskuliburua eta Google Home Integrazio Gida | MP Global
MP Global THERMAEGH termostato adimendunaren erabiltzailearen eskuliburu osoa, instalazioa, funtzionamendua, ezarpenak, arazoak konpontzea eta Google Home-rekin integrazioa jorratzen dituena. Bermeari buruzko informazioa barne hartzen du.