Sarrera
The Seco-Larm E-37EV Alarm Pager System is designed to monitor up to three zones for premises or vehicles, providing alerts via a portable receiver. This system features a 4W output transmitter for extended range and a belt-clip receiver with code-learning capabilities. It is compatible with various alarm control panels and communication systems.
Ezaugarriak
- Monitors up to three zones per premises or vehicle, including manual paging.
- Transmitter can page an unlimited number of receivers.
- Up to ½-mile range in ideal conditions.
- Connects to nearly any type of burglar alarm control panel, vehicle alarm, or communication panel.
- One positive and two negative instant trigger inputs.
- Automatic power antenna control.
- Connects to a CB antenna, car AM radio antenna (cable included), or optional external antenna (E-37ANT).
- Over two million possible coding combinations.
- Belt-clip receiver included.
- Code-learning receiver learns up to three transmitters.
- Color LEDs on the receiver indicate triggered zone (Green, Orange, or Red).
- Audible or vibration page indicator.
- EEPROM memory stores codes for up to one year without power.
- Stores the last six pages for easy recall.
- Unattended page indicator.
- Bateria baxuaren adierazlea.

Image: Features list on the product packaging for the Seco-Larm E-37EV Alarm Pager System.
Paketearen edukia
Egiaztatu osagai guztiak paketean daudela:
- 1 Igorlea
- 1 Vibrating Receiver (Batteries not included)
- 1 Radio Antenna Adapter Cord (18")

Image: Front of the Seco-Larm E-37EV Alarm Pager System box, showing the transmitter, receiver, and kit contents.
Konfigurazioa
Transmisor instalazioa
- Potentzia-konexioa: Connect the transmitter to a 12VDC power source. Ensure proper polarity.
- Antena konexioa: Connect the provided radio antenna adapter cord to the transmitter. For optimal range, consider connecting to a CB antenna, car AM radio antenna, or the optional E-37ANT external antenna. Ensure the antenna body is properly grounded for best performance.
- Trigger sarrerak: Connect the alarm system's trigger outputs to the transmitter's one positive and two negative instant trigger inputs. Refer to your alarm system's manual for specific wiring instructions.
Hargailuaren konfigurazioa
- Bateriaren instalazioa: The receiver requires two AAA batteries (not included). Open the battery compartment and insert the batteries, observing correct polarity.
- Kodearen ikaskuntza: The receiver is designed to learn up to three transmitter codes. Follow the specific instructions provided with the product for the code-learning procedure. This typically involves activating the transmitter while the receiver is in a learning mode.
- Modu aukeraketa: Select between audible or vibration page indication using the switch on the receiver.
Funtzionamendua
Manual Paging
The system supports manual paging. Consult the specific product documentation for instructions on how to initiate a manual page from the transmitter, if applicable.
Zonaren adierazlea
When an alarm is triggered, the receiver's color LEDs will illuminate to indicate which zone was activated:
- LED berdea: Indicates Zone 1 trigger.
- LED laranja: Indicates Zone 2 trigger.
- LED gorria: Indicates Zone 3 trigger.
Page Recall
The receiver stores the last six pages received. Use the recall function (refer to receiver buttons) to review aurreko alertak.
Unattended Page Indicator
If a page is received and not acknowledged, the receiver will provide an unattended page indication (e.g., a flashing LED or repeated alert) until it is cleared.
Bateria baxuaren adierazlea
The receiver features a low battery indicator to alert you when the AAA batteries need replacement.
Mantentzea
Bateria ordezkatzea
When the low battery indicator activates on the receiver, replace the two AAA batteries promptly. Ensure correct polarity during installation.
Garbiketa
Clean the units with a soft, dry cloth. Avoid using abrasive cleaners or solvents, which may damage the casing edo barne osagaiak.
Arazoak konpontzea
| Arazoa | Kausa posiblea | Irtenbidea |
|---|---|---|
| No page received | Receiver batteries low or dead | Ordeztu hargailuaren bateriak. |
| No page received | Transmitter not powered | Check 12VDC power connection to the transmitter. |
| No page received | Transmitter not triggered | Verify alarm system trigger output is connected correctly and functioning. |
| Tarte murriztua | Poor antenna connection or grounding | Ensure antenna is securely connected and properly grounded. Avoid obstructions. |
| Receiver not responding to transmitter | Receiver not coded to transmitter | Perform the code-learning procedure for the receiver. |
Zehaztapenak
| Ezaugarri | Igorlea | Hartzailea |
|---|---|---|
| Number of Codes | Over 2 million factory pre-set | Up to 3 transmitter codes |
| Boterea | 12VDC | 3VDC (2 AAA bateria) |
| RF Irteerako Potentzia | 4W gehienez | N/A |
| Uneko drainatzea | Standby: 10mA, Active: 1A | Standby: 1mA, Active: 50mA |
| Maiztasuna | 27MHz | 27MHz |
| Antena Inpedantzia | 50Ω | N/A |
| Barrutia | Up to ½ mile1 | Up to ½ mile1 |
| Neurriak | 4⅛"x3⅛"x1⅝" (105x79x33mm) | 3"x2⅛"x⅝" (76x54x16mm) |
| Pisua | 5.1 oz (145g) | 1.6-oz (45g) (without battery) |
| Bateriaren iraupena (hartzailea) | N/A | Gutxi gorabehera. 1 hilabete2 |
1Actual range may vary depending on the environment, installation, and/or antenna.
2Based on 5 transmissions/day.

Image: Back of the Seco-Larm E-37EV Alarm Pager System box, detailing transmitter and receiver specifications.
Bermearen informazioa
This Seco-Larm E-37EV Alarm Pager System comes with a 1 urteko bermea from the date of purchase. This warranty covers defects in materials and workmanship under normal use. For warranty claims or service, please contact Seco-Larm customer support.
Laguntza
For further assistance, technical support, or to inquire about optional accessories such as the E-37RV extra vibrating receiver or E-37ANT external antenna, please refer to the official Seco-Larm website or contact their customer service department. Always ensure to follow local regulations and safety guidelines during installation and operation.