Intermatic SW12HWK

Intermatic SW12HWK 12-Hour Spring Wound Timer Instruction Manual

1. Sarrera

The Intermatic SW12HWK is a mechanical, spring-wound timer designed to replace standard wall switches. It provides energy-saving control by automatically limiting the ON time of connected loads such as fans, lights, motors, and heaters. This timer operates without electricity and offers a maximum timing duration of 12 hours, making it suitable for residential and commercial applications.

2. Segurtasun informazio garrantzitsua

Please read and understand all instructions before installing or operating this device. Failure to follow these instructions may result in electrical shock, fire, or property damage.

  • Always turn off power at the circuit breaker or fuse box before installation, maintenance, or servicing.
  • Installation should be performed by a qualified electrician or in accordance with all local and national electrical codes.
  • Do not exceed the specified electrical ratings of the timer. Refer to the 'Specifications' section for details.
  • Gailu hau barrualdean erabiltzeko bakarrik dago pentsatuta.
  • Ensure all wire connections are secure and properly insulated to prevent electrical hazards.

3. Produktuaren ezaugarriak

The Intermatic SW12HWK timer offers several features designed for convenience and energy efficiency:

  • 12-Hour Spring Wound Timer: Provides automatic shut-off for durations up to 12 hours.
  • Energia eraginkorra: Operates mechanically without requiring electricity, contributing to reduced energy consumption and utility costs.
  • Bateragarritasun polifazetikoa: Suitable for controlling various electrical loads including lights (compatible with LED and CFL bulbs), fans, motors, and heaters.
  • Instalazio erraza: Engineered to replace any standard single or multi-gang wall switch. Features upfront terminal connections and a simple press-on knob design.
  • Diseinu iraunkorra: CSA certified for reliability and safety.
Intermatic SW12HWK timer highlighting energy saving features

This image illustrates the timer's key benefits, including its 12-hour spring-wound mechanism and compatibility with LED and CFL lighting, emphasizing energy and cost savings.

4. Instalatzeko jarraibideak

Follow these steps for safe and proper installation of your Intermatic SW12HWK timer:

  1. Itzali energia: Locate the circuit breaker or fuse that controls the switch you are replacing and turn it to the OFF position. Verify that power is off at the switch location using a voltagprobatzailea jarraitu aurretik.
  2. Kendu etengailu zaharra: Carefully remove the existing wall plate and unscrew the old switch from the wall box. Disconnect the wires from the old switch, noting which wire was connected to which terminal if applicable.
  3. Wire the Timer: The SW12HWK timer has two black wires. Connect one black wire from the timer to the 'Hot Wire' (incoming power) in the wall box. Connect the other black wire from the timer to the 'Load Wire' (going to the appliance/light) in the wall box. Use appropriate wire connectors (e.g., wire nuts) to secure these connections.
  4. Muntatu tenporizadorea: Gently push the wired timer into the wall box. Secure the timer to the wall box using the screws provided.
  5. Instalatu horma-plaka: Attach your existing or a new wall plate over the timer. The timer is designed to fit both toggle and decorator style switch plates without field modifications. (Wall plate sold separately).
  6. Lotu botoia: Press the timer knob firmly onto the timer shaft until it is securely seated.
  7. Berrezarri boterea: Piztu berriro korrontea etengailu elektrikoan edo fusible-kutxan.
Wiring diagram for Intermatic SW12HWK timer

This diagram shows a simplified wiring setup for the Intermatic SW12HWK timer, illustrating how to connect the timer's two black wires to the hot and load wires within a standard wall box.

5. Funtzionamendu-argibideak

Operating the Intermatic SW12HWK timer is straightforward:

  • Tenporizadorea ezartzea: To activate the connected load, simply turn the knob clockwise to the desired ON time (e.g., 1 hour, 6 hours, 12 hours). The timer will begin counting down immediately from the selected duration.
  • Itzaltze automatikoa: The connected load will automatically turn OFF once the set time has elapsed.
  • Eskuz OFF: To turn the connected load OFF before the set time expires, rotate the knob counter-clockwise to the 'OFF' position.
Close-up of Intermatic SW12HWK 12-Hour Spring Wound Timer dial

Gertu bat view of the Intermatic SW12HWK 12-Hour Spring Wound Timer, showing the white dial with time markings and the central knob for setting the countdown duration.

Intermatic SW12HWK timer installed in a bathroom

This image depicts the Intermatic SW12HWK timer installed in a bathroom setting, highlighting its function as a countdown timer for various applications such as exhaust fans.

6. Mantentzea

The Intermatic SW12HWK timer is designed for maintenance-free operation under normal conditions.

  • Garbiketa: To clean the timer's surface, wipe it with a soft, slightly damp oihal. Ez erabili garbitzaile urratzailerik, disolbatzailerik edo produktu kimiko gogorrik, hauek akabera edo barneko osagaiak kaltetu baitezakete.
  • Aldizkako ikuskapena: Periodically inspect the timer and its wall plate for any signs of physical damage, loose connections, or unusual operation. If any issues are observed, turn off power at the circuit breaker and consult a qualified electrician for inspection or repair.

7. Arazoak

If you encounter issues with your Intermatic SW12HWK timer, refer to the following troubleshooting guide:

  • Timer does not turn ON:
    • Ensure power is supplied to the circuit. Check the circuit breaker or fuse.
    • Verify that all wiring connections are secure and correctly made according to the installation instructions.
    • Confirm the knob is turned clockwise past the 'OFF' position to a desired time setting.
  • Timer does not turn OFF:
    • Ensure the timer knob is not physically stuck or obstructed.
    • The internal spring mechanism may be faulty. If this is suspected, the unit may require replacement.
  • Intermittent operation or flickering:
    • Check for any loose wiring connections within the wall box.
    • Ensure the total electrical load connected to the timer does not exceed its specified ratings. Overloading can cause erratic behavior.

If these steps do not resolve the issue, contact Intermatic customer support or a qualified electrician.

8. Zehaztapenak

JabetzaBalioa
MarkaIntermatic
Modelo zenbakiaSW12HWK
KoloreaZuria
Karga erresistentea20 Amp, 125 VAC; 10 Amp, 250/277 VAC
Wolframioaren karga7 Amp, 125 VAC
Motor Karga1 HP, 125 VAC; 2 HP, 250 VAC
Maiztasuna50/60 Hz
Aldatu motanorabide bakarrekoa
Muntatze MotaHormako Muntaia
Tenporizadorearen Iraupena12 ordu
ZiurtagiriakCSA ziurtagiria

9. Bermea eta Laguntza

For warranty information, technical assistance, or customer support regarding your Intermatic SW12HWK timer, please contact Intermatic directly. Refer to the official Intermatic webwebgunean edo produktuaren ontzian kontsultatu harremanetarako datu eta berme-baldintza eguneratuenak.

Additional resources, including frequently asked questions and product documentation, may be available on the Intermatic corporate webgunea.

Erlazionatutako dokumentuak - SW12HWK

Aurreview Intermatic Spring Wound Interval Timer Installation and Operation Guide
Detailed installation, operation, and application guide for Intermatic spring wound interval timers (FF and FD models). Includes switch ratings, wiring diagrams, and warranty information.
Aurreview Intermatic Spring Wound Interval Timer Installation Guide
Comprehensive installation and operation guide for the Intermatic Spring Wound Interval Timer, detailing switch ratings, wiring instructions, applications, and warranty information.
Aurreview Intermatic Grässlin CP924 entxufagarri elektronikoaren tenporizadorea: Ezaugarriak eta funtzionamendu argibideak
Intermatic Grässlin CP924 entxufagarri elektronikoaren gida osoa. Ikasi bere ezaugarriei, zehaztapenei eta etxetresna elektrikoetarako ON/OFF orduak nola programatu.
Aurreview Intermatic E-1020 24-Hour Automatic In-Wall Timer: Installation and Operation Guide
Comprehensive guide for installing and operating the Intermatic E-1020 24-hour automatic in-wall multiple program timer. Includes step-by-step instructions, wiring diagrams, and warranty details.
Aurreview Intermatic EJ341C/EJ343C Lighting Timer Switch Installation and Programming Guide
Detailed instructions for installing and programming Intermatic EJ341C (Single Pole) and EJ343C (Three Way) lighting timer switches. Covers setup, controls, programming methods, troubleshooting, and specifications.
Aurreview Intermatic EJ351 Barruko Hormako Etengailu Tenporizadorea: Instalazio, Programazio eta Arazoak Konpontzeko Gida
Intermatic EJ351 Barruko Hormako etengailu-tenporizadorea instalatzeko, programatzeko eta arazoak konpontzeko gida osoa. Ikasi ordutegiak nola ezarri, modu automatikoak eta eskuzkoak nola erabili eta ohiko arazoak nola konpondu.