Sarrera
This manual provides essential information for the safe and efficient use of your Philips Lighting ER55LD3WR LED Exit Sign. Please read these instructions carefully before installation and operation, and retain them for future reference. This product is designed for commercial lighting applications, specifically as a lighted exit sign.
Segurtasun Informazioa
- Always disconnect power before installing or servicing the unit.
- Installation should be performed by a qualified electrician in accordance with national and local electrical codes.
- Ez erabili produktu hau aurreikusitako erabilera ez den beste helburuetarako.
- Ziurtatu konexio guztiak seguru eta behar bezala isolatuta daudela.
- Mantendu uretatik eta gehiegizko hezetasunetik urrun.
Paketearen edukia
Instalazioa hasi aurretik, egiaztatu osagai guztiak daudela:
- Philips Lighting ER55LD3WR LED Exit Sign unit
- Muntatzeko hardwarea (torlojuak, aingurak)
- Argibide eskuliburua (dokumentu hau)
Konfigurazioa eta Instalazioa
The Philips Lighting ER55LD3WR LED Exit Sign is designed for wall mounting. Ensure the mounting surface is suitable to support the weight of the unit.
- Instalazio eremua prestatu: Disconnect power to the circuit where the exit sign will be installed.
- Muntaketa:
- Identify the desired wall mounting location.
- Use the provided mounting hardware to securely attach the exit sign to the wall. Ensure the unit is level.
- Kableatua:
- Connect the building's 120V AC power supply to the corresponding wires on the exit sign. Refer to the wiring diagram inside the unit's housing for specific connections.
- Bermatu lurreratzea egokia.
- Connect the internal battery (if not pre-connected). This is crucial for emergency operation.
- Azken Batzarra: Secure any covers or diffusers.

1. irudia: Aurrealdea view of the Philips Lighting ER55LD3WR LED Exit Sign. This image shows the white housing with the red "EXIT" lettering illuminated, indicating its primary function as an emergency egress indicator.
Funtzionamendu-argibideak
Once installed and power is restored, the Philips Lighting ER55LD3WR LED Exit Sign will operate automatically.
- Funtzionamendu normala: When AC power is present, the "EXIT" sign will be illuminated by the internal LEDs. The green indicator light on the unit will be ON, signifying operating status.
- Larrialdi Eragiketa: In the event of an AC power failure, the unit will automatically switch to battery backup, illuminating the "EXIT" sign for a specified duration (typically 90 minutes).
- Proba botoia: A test button is provided on the unit to verify emergency operation. Press and hold the "Push to Test" button to simulate an AC power failure. The sign should remain illuminated, and the green indicator light will blink, indicating testing. Release the button to return to normal operation.

2. irudia: hurbileko planoa view of the test button and indicator lights on the Philips Lighting ER55LD3WR LED Exit Sign. The green indicator shows operating status (ON for ready, Blinking for testing). The red indicator shows service alerts such as battery, charger board, transformer, or LED strip faults.
Mantentzea
Regular maintenance ensures the reliability and longevity of your LED Exit Sign.
- Hileroko proba: Press the "Push to Test" button for at least 30 seconds to ensure the battery backup system is functioning. The sign should remain illuminated.
- Annual Test: Disconnect AC power to the unit for 90 minutes to verify the battery can sustain emergency illumination for the required duration.
- Garbiketa: Garbitu unitatearen kanpoaldea leun batekin, damp oihal. Ez erabili garbitzaile edo disolbatzaile urratzailerik.
- Bateria ordezkatzea: The internal battery has a limited lifespan. If the unit fails to hold a charge or the red "Battery fault" indicator illuminates, the battery may need replacement. Contact qualified service personnel for battery replacement.
Arazoak konpontzea
Ikusi beheko taula arazo ohikoenak eta haien irtenbideak ikusteko.
| Arazoa | Kausa posiblea | Irtenbidea |
|---|---|---|
| Sign does not illuminate (AC power present) | No AC power; faulty wiring; LED strip fault | Check circuit breaker; verify wiring connections; contact service for LED replacement. |
| Sign does not illuminate during power outage (emergency mode) | Battery not connected; discharged battery; faulty battery; charger board fault | Ensure battery is connected; allow 24 hours for initial charge; replace battery; contact service for charger board repair. |
| Red Service Alert indicator is ON | Indicates battery, charger board, transformer, or LED strip fault (refer to unit label) | Identify specific fault from unit label; perform monthly/annual tests; contact qualified service personnel. |
| Green Operating Status indicator is OFF (AC power present) | No AC power; internal fault | Check AC power supply; contact qualified service personnel. |
Zehaztapenak
| Ezaugarri | Xehetasuna |
|---|---|
| Modelo zenbakia | ER55LD3WR |
| Marka | Philips Argiztapena |
| Argi iturri mota | LED |
| liburukiatage | 120 Volt |
| Energia iturria | Kable elektrikoa |
| Muntatze Mota | Hormako Muntaia |
| Materiala | Metala |
| Kolorea | Zuria |
| Produktuaren neurriak | 4.25 x 6.25 x 4.8 hazbete |
| Elementuaren pisua | 4.98 kilo |
| UPC | 781370410117 |
Bermea eta Laguntza
For warranty information or technical support, please contact Philips Lighting customer service. Keep your purchase receipt as proof of purchase.
Fabrikatzailea: Philips Argiztapena
Webgunea: Visit the PHILIPS Store on Amazon