True TRUE988284

True 988284 Temperature Control Kit 077B6856 Instruction Manual

Model: TRUE988284

1. Produktua amaitu daview

The True 988284 Temperature Control Kit 077B6856 is a genuine Original Equipment Manufacturer (OEM) replacement part designed for True Refrigeration units. This kit ensures the proper regulation of temperature within your commercial refrigeration equipment, maintaining optimal operating conditions for safety, reliability, and performance.

True 988284 Temperature Control Kit with dial and capillary tube

1.1. irudia: Amaituview of the True 988284 Temperature Control Kit, showing the control unit, dial, and capillary tube.

Ezaugarri nagusiak:

2. Segurtasun informazioa

Garrantzitsua: Read all instructions carefully before installation or operation. Failure to follow these instructions may result in property damage, personal injury, or death.

3. Paketearen edukia

Paketea irekitzean, egiaztatu osagai guztiak daudela eta kalterik gabe daudela.

Components of the True 988284 Temperature Control Kit including control unit, dial, screws, and connectors

Image 3.1: Contents of the True 988284 Temperature Control Kit, typically including the control module, temperature dial, mounting screws, and electrical connectors.

4. Instalatzeko jarraibideak

This section provides general guidance for replacing a temperature control kit. Specific installation steps may vary depending on your True Refrigeration model. Refer to your unit's service manual for detailed, model-specific instructions.

  1. Deskonektatu energia: Locate the main power supply to the refrigeration unit and disconnect it. Verify that power is off using a voltage probatzailea.
  2. Access Control Area: Depending on your unit, you may need to remove access panels or grilles to reach the existing temperature control.
  3. Dokumentuen kableatzea: Before disconnecting any wires, take clear photos or make a diagram of the existing wiring connections to the old temperature control. Note the position of the capillary tube sensor.
  4. Kendu kontrol zaharra:
    • Carefully disconnect the electrical wires from the old control.
    • Unmount the old control from its housing.
    • Gently remove the capillary tube sensor from its sensing location (e.g., evaporator coil, air return).
  5. Install New Control:
    • Insert the new capillary tube sensor into the exact same sensing location as the old one. Ensure it is securely positioned for accurate temperature readings. Avoid kinking or damaging the tube.
    • Mount the new temperature control module in the same position as the old one using the provided screws.
    • Connect the electrical wires to the new control according to your documented wiring diagram. Ensure connections are secure.
  6. Berriz muntatu: Replace any access panels or grilles that were removed.
  7. Berrezarri boterea: Reconnect the main power supply to the refrigeration unit.
  8. Proba funtzionamendua: Allow the unit to run for a period and monitor the temperature to ensure proper operation and temperature regulation. Adjust the dial as needed.

Oharra: If you are unsure about any step, consult a qualified refrigeration technician.

5. Funtzionamendu-argibideak

The temperature control kit features a rotary dial for adjusting the desired temperature within your True Refrigeration unit.

6. Mantentzea

The True 988284 Temperature Control Kit is designed for durability and reliability. Regular maintenance of the overall refrigeration unit is crucial for its longevity and efficient operation.

7. Arazoak

If your refrigeration unit is experiencing temperature issues after installing this kit, consider the following common troubleshooting steps:

ArazoaKausa posibleaIrtenbidea
Unit not cooling or too warm
  • Temperature dial set too high (warmer)
  • Capillary tube not properly seated or damaged
  • Konexio elektriko soltea
  • Other refrigeration system issues (e.g., low refrigerant, dirty condenser)
  • Adjust dial to a colder setting.
  • Verify capillary tube placement and condition.
  • Check and secure all wiring connections (with power disconnected).
  • Consult a qualified technician for system diagnosis.
Unit freezing contents or too cold
  • Temperature dial set too low (colder)
  • Capillary tube sensing incorrect temperature (e.g., too close to evaporator)
  • Kontrol-unitatearen matxura
  • Adjust dial to a warmer setting.
  • Ensure capillary tube is correctly positioned away from direct evaporator contact if applicable.
  • If issues persist, the control unit may require replacement or further diagnosis by a technician.
Tenperatura asko aldatzen da
  • Improper capillary tube placement
  • Kontrol-unitatearen matxura
  • Refrigeration system issues
  • Verify capillary tube placement.
  • Consult a qualified technician for diagnosis.

Abisua: Do not attempt repairs beyond your technical capabilities. Always prioritize safety and consult a professional for complex issues.

8. Zehaztapenak

EzaugarriXehetasuna
MarkaEgia
Modelo zenbakiaEGIA988284
Produktuaren neurriak6 x 6 x 4 hazbete
Elementuaren pisua4.8 ontza
Eragiketa moduaAutomatikoa
Kontaktu motaNormalean irekita
Konektore motaTorloju terminalak
TerminalaTorlojua
Zirkuitu Motanorabide bakarrekoa
Muntatze MotaGainazaleko muntaia
Eragile motaSakatu botoia
Harremanetarako materialaKobrea, Letoia
Eskuragarri dagoen lehen data15ko ekainaren 2011a

9. Bermea eta Laguntza

As a genuine OEM part, this True 988284 Temperature Control Kit is manufactured to high standards. For specific warranty information, please refer to the documentation provided with your original True Refrigeration unit or contact True Refrigeration directly.

Bezeroarentzako laguntza:

For technical assistance, troubleshooting beyond this manual, or to inquire about warranty claims, please contact True Refrigeration customer support or an authorized service provider.

Erlazionatutako dokumentuak - EGIA988284

Aurreview Egiazko Kommerzielle Kühltechnik: Allgemeiner Regelungsleitfaden
Umfassender Leitfaden zur Bedienung, Einstellung und Fehlerbehebung von Temperaturregelungen True kommerziellen Kühl- und Gefriergeräten. Enthält Anleitungen für mechanische und elektronische Steuerungen sowie spezifische Modellinformationen.
Aurreview TRUE Fabrikazio Instalazio Eskuliburua Hasiberrientzako Gida Azkarra
Dokumentu honek TRUE Manufacturing-en hozte eta berogailu komertzialen instalazio, funtzionamendu eta mantentze-lanetarako oinarrizko jarraibideak eskaintzen ditu. Segurtasun-abisuak, zehaztapenak, konfigurazio-prozedurak eta zaintza-argibideak biltzen ditu.
Aurreview True TH Modeloen Berogailudun Armairuen Instalazio Eskuliburua
True TH Models berogailudun armairuen instalazio, funtzionamendu eta mantentze-lanetarako gida osoa. True Manufacturing Co., Inc.-en segurtasun, elektrizitate, konfigurazio, zaintza eta bermeari buruzko informazioa biltzen du.
Aurreview True T-23DF-HC Hozkailu/Izozkailu Komertzialen Instalazio eta Erabilera Eskuliburua
True T-23DF-HC hozkailu/izozkailu komertzial bikoitzeko instalazio, funtzionamendu, mantentze eta segurtasun gida osoa. Arazoak konpontzea, garbiketa argibideak eta bermearen informazioa barne hartzen ditu.
Aurreview True CVM Seriearen Instalazio Eskuliburua
True CVM serieko hozte-unitateen instalazio, funtzionamendu eta mantentze-lanetarako eskuliburu osoa. Segurtasun-neurriak, eskakizun elektrikoak, instalazio-prozedurak, berdintzea, zigilatzea, apalategien muntaketa eta mantentze-lan orokorra biltzen ditu.
Aurreview Manuel d'Installation et de Démarrage Rapide True
Instalaziorako, erabiltzeko eta mantentzeko gailuen gida osoa True Manufacturing Co., Inc. Hozteko eta kontserbatzeko gailuak. Segurtasun funtsezko informazioa eta laguntzarako baliabideak barne.