SIMPLEX 4099-9005

Simplex 4099-9005 Addressable Manual Pull Station (Dual Action) User Manual

Eredua: 4099-9005

1. Sarrera

The Simplex 4099-9005 is an addressable manual pull station designed for use with compatible Simplex fire alarm control panels. This dual-action device requires two distinct operations to activate, reducing the likelihood of accidental activation. It is an integral component of a comprehensive fire detection and alarm system, providing a manual means for occupants to initiate an alarm in the event of a fire or other emergency.

2. Segurtasun informazioa

Segurtasun-argibide garrantzitsuak:

3. Produktua amaitu daview

The Simplex 4099-9005 is a red, dual-action manual pull station. Its addressable nature allows the fire alarm control panel to identify the exact location of the activated station. The dual-action design requires a two-step process for activation: first, pushing in a bar, and then pulling down a handle.

Aurrealdea view of the Simplex 4099-9005 Addressable Manual Pull Station, showing the 'FIRE ALARM' label, 'PUSH BAR', and 'PULL HANDLE'.

1. irudia: Aurrealdea view of the Simplex 4099-9005 Addressable Manual Pull Station. This image displays the primary components including the 'FIRE ALARM' text, the 'PUSH BAR' mechanism, and the 'PULL HANDLE' for activation.

4. Instalazioa

Proper installation is crucial for the reliable operation of the manual pull station.

4.1 Muntaketa

4.2 Kableatua

4.3 Helbidea ezartzea

The 4099-9005 is an addressable device. Before connecting to the SLC, set the unique address for the pull station using the appropriate Simplex programming tool or DIP switches, as specified in the device's technical documentation. Each device on the SLC must have a unique address.

Aldea view of the Simplex 4099-9005 Addressable Manual Pull Station, showing its depth and mounting points.

2. irudia: Aldea view of the Simplex 4099-9005 Addressable Manual Pull Station. This image illustrates the depth of the unit and provides a perspective on its mounting configuration.

5. Funtzionamendua

5.1 Alarma aktibatzea

In the event of a fire or emergency, follow these steps to activate the manual pull station:

  1. Sartu barrura: Firmly push the bar labeled "PUSH BAR" on the front of the station.
  2. Tira behera: Once the bar is pushed in, pull down the handle labeled "PULL HANDLE" until it latches in the down position.

Activation will send an alarm signal to the fire alarm control panel, initiating the building's alarm sequence.

5.2 Tiratzeko estazioa berrezartzea

After an alarm has been activated and the emergency resolved, the pull station must be reset. The Simplex 4099-9005 requires a B-Key for resetting.

  1. Insert B-Key: Locate the keyhole on the front of the pull station. Insert the B-Key into the keyhole.
  2. Turn Key: Turn the B-Key clockwise or counter-clockwise (depending on the specific mechanism) to release the latched handle.
  3. Itxi azala: Return the handle to its original, unactivated position and close the front cover.
  4. Remove B-Key: Remove the B-Key.

The B-Key is considered a tool for maintenance and resetting, not a consumable item. If additional B-Keys are required, they can be ordered using PID: 252-019.

6. Mantentzea

Regular maintenance ensures the continued reliability of your Simplex 4099-9005 pull station.

7. Arazoak

If you encounter issues with your Simplex 4099-9005 pull station, consider the following:

For persistent issues, contact a qualified fire alarm technician.

8. Zehaztapenak

EzaugarriZehaztapena
MarkaSIMPLEA
Modelo zenbakia4099-9005
EstiloaSegurtasuna
Energia iturriaEskuliburua
Elementuaren pisua3.53 ontza (100 gramo)
Alarma motaAudible (via FACP)
MaterialaGlass (referring to break-glass type, though this model is dual-action)
Produktuaren neurriak1 x 3.4 x 5 hazbete
UPC643485652991
Zati zenbakiaS4099-9005
Beharrezko bateriakEz

9. Bermearen informazioa

Specific warranty details for the Simplex 4099-9005 Addressable Manual Pull Station are typically provided at the point of purchase or can be obtained directly from Simplex or an authorized distributor. Please retain your proof of purchase for warranty claims. For detailed warranty terms and conditions, refer to the official Simplex documentation or contact their customer service.

10. Bezeroarentzako arreta

For technical assistance, installation queries, or service requests, please contact your authorized Simplex dealer or a certified fire alarm technician. Ensure you have the product model number (4099-9005) and any relevant system information available when seeking support.

Erlazionatutako dokumentuak - 4099-9005

Aurreview Simplex IDNet/MAPNET II Helbideragarri Eskuzko Suteen Alarma Estazioak - Produktuaren Datuak
Simplex 4099 Serieko eskuzko suteen alarma-estazio helbideragarriei buruzko informazio zehatza, IDNet eta MAPNET II sistemekin bateragarriak. Ezaugarriak, zehaztapenak, muntatzeko aukerak eta produktuen hautaketa hainbat modelotarako, ekintza bakarreko, ekintza bikoitzeko (kristala hautsiz eta bultzada bidez) eta GRIP GABEko aukerak barne. ADAren eskakizunak betetzen ditu eta UL, ULC, FM eta CSFM-k zerrendatzen dute.
Aurreview Simplex Addressable Manual Stations: IDNet/MAPNET II Peripherals
Explore Simplex addressable manual fire alarm stations, detailing their features, single/double action types, NO GRIP options, and compatibility with IDNet/MAPNET II systems. Includes mounting and specification information.
Aurreview Simplex 2099 Serieko Ekintza Bakarreko eta Bikoitzeko Eskuzko Suteen Alarma Estazioen Datu-orria
Simplex 2099 Serieko eskuzko suteen alarma-zentralen datu-orria, kodetu gabeko eta helbiderik gabekoak. Ezaugarriak, funtzionamendu motak, aplikazio erreferentziak, produktuen hautaketa, muntaketa aukerak eta zehaztapenak biltzen ditu.
Aurreview Simplex 4010ES: Desagertzeko agindu automatikorako sistemak
Gida-teknika Simplex 4010ES-ek desagertzeko sistema automatikoetarako aginte-modulak xehatzen ditu gicleur-en bidez, deluge- eta prebentzio-moduak jorratu, zehaztapen, homologazio eta kablaje eskemekin.
Aurreview Simplex 4099-9801C IDNet™ 2-Stage Station IAM Installation Instructions
Installation instructions for the Simplex 4099-9801C IDNet™ 2-Stage Station Individual Addressable Module (IAM). Covers mechanical installation, electrical connections, and address configuration for fire alarm systems.
Aurreview Simplex 4004 Suteen Alarma Kontrol Panela: Instalazio eta Erabilera Argibideak
Simplex 4004 Suteen Alarma Kontrol Panela (FACP) instalatzeko, erabiltzeko eta programatzeko gida osoa, sistemaren gaineko kontrola barne.view, eskakizunak, kableatuak, moduluen deskribapenak eta arazoak konpontzea.