Cooper Lighting SDC15

SDC15-W Skye Fan/Light Control

Model: SDC15 | Brand: Cooper Lighting

Sarrera

This manual provides detailed instructions for the installation, operation, and maintenance of your Cooper Lighting SDC15-W Skye Fan/Light Control. Please read all instructions carefully before beginning installation or use to ensure proper function and safety.

Segurtasun Informazioa

OHARRA: To avoid fire, shock, or death; turn off power at circuit breaker or fuse box and test that the power is off before wiring. This device is intended for installation in accordance with the National Electric Code and local regulations. It is recommended that a qualified electrician perform this installation.

KONTUZ: For indoor use only. Do not exceed the maximum wattage edo amperage ratings. This device is designed for incandescent light fixtures up to 300W and ceiling fans up to 1.5A. Not for use with fluorescent lights, LED lights, or exhaust fans.

Konfigurazioa eta Instalazioa

Before installation, ensure the power to the circuit is turned off at the circuit breaker. This control is designed for single-gang wall box installation and supports 3-way circuit configurations.

Kableatzeko jarraibideak

  1. Identify the Line (hot), Load (to fan/light), and Ground wires from your wall box.
  2. Connect the green ground wire from the SDC15 to the bare copper or green ground wire in the wall box.
  3. Connect the black wire labeled 'BK' (Common/Line) from the SDC15 to the incoming Line (hot) wire.
  4. Connect the yellow wire labeled 'YL Light' from the SDC15 to the wire leading to your light fixture.
  5. Connect the yellow wire labeled 'YL Fan' from the SDC15 to the wire leading to your ceiling fan.
  6. Secure all wire connections with appropriate wire nuts.
Itzuli view of the SDC15-W Fan/Light Control showing wiring terminals

Irudia: Atzealdea view of the SDC15-W control, illustrating the screw terminals for wiring connections. Labels for 'YL Light', 'BK', 'YL Fan', and 'GND' are visible, indicating connections for light, common/line, fan, and ground respectively. This view is crucial for correct electrical installation.

Aldea view of the SDC15-W Fan/Light Control

Irudia: Alboko profesionalafile of the SDC15-W control, showing its depth and mounting bracket. This view helps in understanding the physical dimensions for fitting into a standard wall box.

Muntaketa

  1. Carefully push the wired control into the wall box.
  2. Lotu kontrola hormako kaxari emandako muntaketa-torlojuak erabiliz.
  3. Attach the wall plate (not included) over the control.
  4. Berrezarri energia etengailuan.

Funtzionamendu-argibideak

The SDC15-W features two independent slider controls: one for the ceiling fan speed and one for the light dimmer.

Aurrealdea view of the SDC15-W Fan/Light Control

Irudia: Aurrealdea view of the SDC15-W Fan/Light Control, showcasing the two vertical slider controls. The left slider has a fan icon, and the right slider has a light bulb icon, with an 'OFF' position clearly marked between them. This is the primary user interface for controlling fan speed and light intensity.

Fan Abiadura Kontrola

  • To turn the fan ON, slide the left control lever upwards from the 'OFF' position.
  • Slide the lever further upwards to increase fan speed.
  • Slide the lever downwards to decrease fan speed.
  • To turn the fan OFF, slide the lever all the way down to the 'OFF' position.

Argiaren dimmer kontrola

  • To turn the light ON, slide the right control lever upwards from the 'OFF' position.
  • Slide the lever further upwards to increase light brightness.
  • Slide the lever downwards to decrease light brightness.
  • To turn the light OFF, slide the lever all the way down to the 'OFF' position.

Mantentzea

The SDC15-W Fan/Light Control requires minimal maintenance. Ensure the power is off before cleaning.

  • Clean the surface of the control with a soft, damp oihal. Ez erabili garbitzaile edo disolbatzaile urratzailerik.
  • Periodically check the mounting screws for tightness.
  • No user-serviceable parts inside. Do not attempt to disassemble the unit.

Arazoak konpontzea

ArazoaKausa posibleaIrtenbidea
Fan/Light does not turn ON.No power to the control; Incorrect wiring; Blown fuse/tripped breaker.Check circuit breaker/fuse. Verify wiring connections. Ensure power is restored.
Fan speed or light brightness does not change.Incorrect wiring; Incompatible fan/light type; Control is faulty.Verify wiring. Ensure fan/light is compatible (incandescent for light, standard ceiling fan for fan). Replace control if necessary.
Fan hums or wobbles.Fan motor incompatibility; Fan balance issue.Ensure fan is compatible with solid-state speed controls. Check fan blade balance.
Argia keinuka edo burrunba egiten du.Incompatible bulb type; Loose bulb; Overloaded circuit.Ensure incandescent bulbs are used. Tighten bulb. Reduce total wattage if exceeding 300W.

Zehaztapenak

EzaugarriXehetasuna
Modelo zenbakiaSDC15
Eragiketa moduaEskuliburua
Uneko balorazioa (haizagailua)1.5 Amps
Wattage (Argia)300 Watts (Incandescent Max)
Bolumen eragileatage120 Volt
Maiztasuna60 Hz
Zirkuitu Motanorabide bakarrekoa
Kontaktu motaNormalean irekita
Konektore motaTorlojua
Eragile motaPush Button (Slider)
Kontrol-metodoaTouch (Slider)
KoloreaZuria
Neurriak (L x W x H)4.25 x 1.75 x 2 hazbete
Elementuaren pisua4.8 ontza
Nazioarteko Babesteko BalorazioaIP44
FabrikatzaileaCooper Industries

Bermearen informazioa

Warranty information for the Cooper Lighting SDC15-W Fan/Light Control is typically provided with your purchase or can be obtained directly from the manufacturer. Please retain your proof of purchase for warranty claims.

Bezeroarentzako Arreta

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact Cooper Lighting customer support. Refer to the packaging or the official Cooper Lighting webgunea kontaktu-informazio eguneratuena lortzeko.

Erlazionatutako dokumentuak - SDC15

Aurreview Cooper Lighting Occupancy and Vacancy Sensors Catalog
Product catalog from Cooper Lighting featuring a range of ultrasonic, PIR, and dual technology occupancy and vacancy sensors for various applications, including wall, ceiling, and fixture mount. Details include catalog numbers, descriptions, UPC codes, weights, quantities, and country of origin.
Aurreview LENSGO 15A COB LED argia: Argibide eskuliburua eta zehaztapenak
LENSGO 15A COB LED argiaren argibide eskuliburu osoa. Ikasi argazkilaritzarako argiztapen-soluzio eramangarri honen konfigurazioari, funtzionamenduari, ezaugarriei, zehaztapenei eta segurtasun-neurriei buruz.
Aurreview Eaton xDetect-en txosten zuria: CF3000 sute-paneletik xDetect-era migratzea
A white paper from Eaton exploring the migration path from the discontinued CF3000 fire control panel range to the new xDetect system, focusing on safety, compliance, cost efficiency, and business continuity. It details the challenges of discontinuation and the benefits of upgrading.
Aurreview GL LED US Lighting OMP-300W-12V LED kontrolatzailea - 300W, 12V DC, IP68
GL LED US Lighting OMP-300W-12V LED kontrolatzailearen zehaztapen zehatzak. 300W-ko irteera maximoa, 12V DC, 90-277VAC sarrera, IP68 sailkapena, 5 urteko bermea eta bolumen konstantea ditu.taghainbat argiztapen aplikaziotarako funtzionamendua.
Aurreview PROLIGHTS EclExpo Flood300VW User Manual: 300W Asymmetric LED Floodlight
Comprehensive user manual for the PROLIGHTS EclExpo Flood300VW, a 300W asymmetric LED floodlight with variable white CCT (2,700K - 6,500K). Covers safety, installation, DMX control, RDM functions, maintenance, and troubleshooting.
Aurreview Harbor Breeze 300W Landscape Lighting Transformer Installation and Operation Manual
Comprehensive guide for installing and operating the Harbor Breeze 300W Landscape Lighting Transformer, including safety instructions, assembly steps, wiring guidance, operating modes, troubleshooting, and warranty information.