American Volt AV-1022

Universal Electric Radiator Cooling Fan Thermostat Temp Sensor Switch User Manual

Brand: American Volt | Model: AV-1022

1. Sarrera eta Produktuaren Azalpenaview

This manual provides detailed instructions for the installation, operation, and maintenance of your American Volt Universal Electric Radiator Cooling Fan Thermostat Temp Sensor Switch. This product is designed to automatically control electric cooling fans in automotive applications based on engine or fluid temperature.

The kit includes two temperature sensor switches, each featuring a brass thread-in probe compatible with 3/8" and 1/2" NPT threaded ports. The switch is engineered to activate (ground) the cooling fan when the temperature reaches 180°F and deactivate it when the temperature drops to 165°F, ensuring optimal engine cooling.

Two brass temperature sensor switches with electrical terminals

Image 1.1: Two American Volt Universal Electric Radiator Cooling Fan Thermostat Temp Sensor Switches. These are the primary components of the product, showing their brass construction and electrical terminals.

2. Produktuaren ezaugarriak

Gertutik view of a single brass temperature sensor switch

2.1 irudia: Xehetasun zehatza view of a single American Volt temperature sensor switch. This image highlights the brass probe and the threaded body, which allows for secure installation into various automotive components.

3. Zehaztapenak

ZehaztapenaBalioa
Eragiketa moduaAutomatikoa
Bolumen eragileatage12 voltio (DC)
Kontaktu motaNormalean irekita
Konektore motaTorlojua
TerminalaTorlojua
Zirkuitu Motanorabide bakarrekoa
Muntatze MotaHaridun mendia
Harremanetarako materialaLetoia
Nazioarteko Babesteko BalorazioaIP00
Postu kopurua2
Lower Temperature Rating (Turn-Off)165 gradu Fahrenheit
Upper Temperature Rating (Turn-On)180 gradu Fahrenheit
Unitate kopurua2.0 zenbaketa
Fabrikatzailearen pieza zenbakiaAV-1022

4. Konfigurazioa eta instalazioa

Proper installation is crucial for the correct operation of the temperature sensor switch. Always disconnect the vehicle's battery before beginning any electrical work.

4.1. Instalazio kokapena aukeratzea

The sensor can be threaded into any suitable 1/2" NPT port that accurately reflects the temperature of the fluid you wish to monitor. Common locations include:

Ensure the chosen location allows the brass probe to be fully immersed in the fluid for accurate temperature readings. If your port is 3/8" NPT, use the provided adapter.

NPT American Standard Pipe Thread Taper Guide

Image 4.1: NPT - American Standard Pipe Thread/Taper Guide. This guide helps in identifying the correct NPT size for your application, ensuring a proper fit for the sensor switch.

4.2. Instalazio Mekanikoa

  1. Ensure the engine and cooling system are cool to prevent burns.
  2. Drain a small amount of coolant if installing directly into the cooling system to prevent spills.
  3. Apply a suitable thread sealant (e.g., PTFE tape or liquid thread sealant) to the threads of the sensor probe.
  4. Carefully thread the sensor into the chosen port. Do not overtighten, as this can damage the sensor or the port. Tighten until snug and leak-free.
  5. Refill any drained coolant and check for leaks.

4.3. Kableatu elektrikoa

The sensor switch operates by providing a ground signal to activate a relay, which in turn powers the electric cooling fan. Refer to the wiring diagram below for proper connections.

Wiring diagram for electric cooling fan thermostat switch

Image 4.2: Typical Wiring Diagram for Electric Cooling Fan Thermostat Switch. This diagram illustrates how to connect the temperature sensor switch to a relay, circuit breaker, battery, and the electric fan for automatic operation.

  1. Connect to Sensor: Use the provided insulated female wire connectors to attach a wire to the single terminal on the temperature sensor switch.
  2. Connect to Relay: Connect the other end of this wire to the appropriate terminal on your fan relay (typically pin 85 or the coil ground terminal).
  3. Power and Fan Connections: Follow the relay manufacturer's instructions for connecting the relay to the battery (via a circuit breaker), ignition/fan switch (if applicable), and the electric cooling fan. Ensure all connections are secure and properly insulated.
  4. Lurreratzea: Ensure the fan and battery have proper chassis grounds. The sensor switch provides a ground signal to the relay.

Garrantzitsua: Always use an appropriately rated circuit breaker or fuse in the main power line to protect the circuit.

5. Funtzionamendu-argibideak

Once properly installed and wired, the American Volt temperature sensor switch operates automatically. There are no user-adjustable settings.

This cycle will repeat as necessary to maintain the desired operating temperature range for your cooling system.

6. Mantentzea

The American Volt temperature sensor switch is designed for long-term, maintenance-free operation. However, periodic checks can help ensure continued reliability:

7. Arazoak

If your electric cooling fan is not operating as expected with the temperature sensor switch, consider the following troubleshooting steps:

ArazoaKausa posibleaIrtenbidea
Fan does not turn on at 180°FNo power to relay; Faulty relay; Open circuit in wiring; Sensor not reaching temperature; Faulty sensorCheck circuit breaker/fuse; Test relay operation; Inspect all wiring connections (refer to Image 4.2); Verify engine/fluid temperature with a separate gauge; Test sensor continuity (should show continuity when hot); Replace faulty component.
Haizagailuak etengabe funtzionatzen duSensor stuck closed (grounded); Wiring shorted to ground; Faulty relayDisconnect sensor wire from relay; if fan stops, sensor is faulty. If fan continues, check wiring for shorts or replace relay.
Tenperaturaren irakurketa okerrakSensor not fully immersed in fluid; Air pocket around sensor; Incorrect sensor typeEnsure sensor probe is fully submerged; Bleed cooling system to remove air; Verify correct sensor for application.
Fluid leaks around sensorInsufficient thread sealant; Overtightened/damaged threadsRemove, reapply thread sealant, and reinstall; Inspect threads for damage; Replace sensor or port if threads are stripped.

Arazoa konpontzeko urratsek ez badute konpontzen, komenigarria da automobilgintzako teknikari kualifikatu batekin kontsultatzea.

8. Bermearen informazioa

Specific warranty details for American Volt products are typically provided at the point of purchase or on the manufacturer's official website. Please retain your proof of purchase for any warranty claims. For the most current and detailed warranty information, please refer to the American Volt official webgunera edo jarri harremanetan zuzenean bezeroarentzako arreta-zerbitzuarekin.

9. Laguntza

For technical assistance, product inquiries, or support, please contact American Volt customer service. Visit the official American Volt webharremanetarako informazioa, maiz egiten diren galderak eta baliabide gehigarriak dituen gunea.

American Volt Store: Visit the American Volt Store on Amazon

Erlazionatutako dokumentuak - AV-1022

Aurreview American Volt Dual Electric Fan Wiring Harness Installation Guide
Comprehensive installation instructions for the American Volt Dual Electric Fan Wiring Harness, detailing safety precautions, component connections, and kit assembly.
Aurreview American Volt Adjustable Thermostat Kit Installation Instructions (Model AV-B69)
Comprehensive installation guide for the American Volt AV-B69 adjustable thermostat kit, detailing wiring, probe placement, and safety precautions for vehicle electric radiator fans.
Aurreview Installation Instructions for American Volt Manual Toggle Switch Kit
Detailed installation guide for the American Volt manual toggle switch kit, including wiring instructions, troubleshooting tips, and safety warnings for electric fan systems.
Aurreview Nola sartu AViPAS kameretara IP bidez - Sarearen konfigurazio gida
AViPAS IP kameretara zuzenean zure ordenagailura Ethernet bidez konektatuz sartzeko urratsez urratseko gida, Windows eta macOS-erako sare konfiguraziorako argibide zehatzekin.