Sarrera
The SurgeX ESP SEQ-1U is a 20 Amp/120V power sequencer and conditioner designed to protect and manage power for sensitive audio/video systems. It ensures proper power-up and power-down sequences, preventing damaging pops, hissing sounds, and excessive inrush currents. This manual provides essential information for the safe and effective operation of your SEQ-1U unit.
Segurtasun Informazioa
OHARRA:
- Ez jarri unitatea euri edo hezetasunera.
- Ez ireki c-a.asing; there are no user-serviceable parts inside. Refer all servicing to qualified service personnel.
- Ziurtatu lurra egokia deskarga elektrikoa saihesteko.
- Deskonektatu korrontea konexioak egin edo mantentze-lanak egin aurretik.
- Unitate hau barrualdean erabiltzeko diseinatuta dago.
Produktua amaituview
Aurrealdeko panela

Figure 1: Front Panel of the SurgeX ESP SEQ-1U
The front panel of the SEQ-1U features the SurgeX brand logo and model number. A central LCD display shows the unit's status, including voltage (e.g., "STATUS: ALL OFF 118V") and protection status (e.g., "PROTECTION: GOOD"). To the left of the display, a key switch with associated lock icons provides security. On the right, "SEL" and "ADJ" buttons are used for navigation and adjustment, alongside a prominent blue "POWER" button.
Ezaugarri nagusiak
- 20 Amp/120V Power Sequencer/Conditioner
- Adjustable 0-40 Second Sequence Delay
- 2 entxufe beti piztuta
- 3 Sequence Banks
- 8-outlet total capacity
- Advanced surge elimination
- EMI/RFI iragazkia
- Muturreko voltage babesa
Konfigurazioa
Rack Muntaketa
The SEQ-1U is designed for standard 19-inch rack mounting. Secure the unit using appropriate rack screws (not included) to ensure stability. Allow adequate ventilation around the unit.
Potentzia-konexioa
- Ensure the main power switch on the SEQ-1U is in the OFF position.
- Connect the unit's power cord to a dedicated 20 Amp, 120V AC power outlet.
- Verify that the power source is stable and within the specified voltagbarrutia.
Konektatzeko ekipoak
The SEQ-1U features two always-on outlets and three sequenced banks, each with two outlets.
- Connect equipment that requires constant power (e.g., network routers, media servers) to the "Always On" outlets.
- Connect equipment that should power on/off in a specific order (e.g., pre-amplifiers, power amplifiers, projectors) to the sequenced outlets (Banks 1, 2, and 3).
- Refer to your system's specific power-up/down requirements to determine the correct sequencing order for your devices.
Funtzionamendu-argibideak
Piztu/Itzaltzea
- Insert the key into the key switch on the front panel and turn it to the "ON" position.
- Press the blue "POWER" button. The unit will begin its power-up sequence, activating the sequenced banks with the configured delays.
- To power off, press the blue "POWER" button again. The unit will initiate the power-down sequence in reverse order.
- For complete power disconnection, turn the key switch to the "OFF" position and/or unplug the unit from the wall outlet.
Adjusting Sequence Delay
The SEQ-1U allows adjustment of the delay between sequenced banks (0-40 seconds).
- Use the "SEL" button to navigate through menu options on the LCD display.
- Use the "ADJ" button to modify the selected value (e.g., sequence delay time).
- Consult the on-screen prompts for specific instructions on saving your custom settings in non-volatile memory.
LCD pantailaren informazioa
LCD pantailak denbora errealeko egoeraren eguneraketak eskaintzen ditu:
- EGOERA: Indicates the current state of the outlets (e.g., "ALL OFF", "BANK 1 ON") and the input voltage.
- BABES: Displays the status of the surge protection (e.g., "GOOD", "FAULT").
Mantentzea
- Garbiketa: Deskonektatu korrontea garbitu aurretik. Erabili zapi leun eta lehor bat unitatearen kanpoaldea garbitzeko. Ez erabili garbitzaile likidorik edo aerosolik.
- Aireztapena: Ensure that ventilation openings are not blocked. Proper airflow is crucial for preventing overheating.
- Kableen kudeaketa: Keep power cables neatly organized and away from signal cables to prevent interference.
Arazoak konpontzea
| Arazoa | Kausa posiblea | Irtenbidea |
|---|---|---|
| Unitatea ez da pizten. | No power from wall outlet; key switch in OFF position; tripped circuit breaker. | Check wall outlet with another device; ensure key switch is ON; reset circuit breaker. |
| Equipment not powering on in sequence. | Incorrect connection to outlets; sequence delay set too long/short; unit in bypass mode. | Verify connections to sequenced banks; adjust sequence delay; ensure unit is in normal operating mode. |
| "PROTECTION: FAULT" displayed. | Internal protection circuit activated due to severe surge. | Disconnect all equipment, power cycle the unit. If fault persists, contact SurgeX support. |
Zehaztapenak
- Eredua: SEQ-1U
- Sarrera boltage: 120 V AC
- Egungo edukiera: 20 Amp
- Saltokiak: 8 (2 Always-on, 6 Sequenced in 3 banks)
- Sequence Delay: 0-40 segundo erregulagarria
- Neurriak (L x W x H): 21.7 x 15.05 x 6.7 hazbete
- Pisua: 16.65 kilo
- Material mota: Kobrea
- Gaindituen babesa: Advanced Series Mode® surge elimination
- Iragazkia: EMI/RFI iragazkia
Bermea eta Laguntza
For warranty information, technical support, or service inquiries, please contact SurgeX customer service. Refer to the official SurgeX webwebgunean edo erosketa-dokumentazioan, azken harremanetarako datuak eta berme-baldintzak ikusteko.
Sareko baliabideak: Visit the SurgeX official webMaiz egiten diren galderen, produktuen erregistroaren eta laguntza-material gehigarrien gunea.