1. Sarrera
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your U.S. Solid Motorized Ball Valve, Model USS-MSV00052. This 1/4 inch, 85-265V AC, 2-wire automatic return valve is designed for various applications requiring reliable fluid control. Please read this manual thoroughly before use and retain it for future reference.
2. Segurtasun informazioa
Abisua: Improper installation or operation can result in property damage, injury, or death. Always follow local codes and regulations.
- Ensure power is disconnected before performing any installation, wiring, or maintenance.
- Installation should be performed by qualified personnel familiar with electrical and plumbing systems.
- Verify the valve's voltage rating (85-265V AC) matches your power supply.
- Do not exceed the maximum operating pressure of 1000 Pascal.
- Protect the valve from extreme temperatures and corrosive environments unless specifically rated for such conditions.
3. Produktua amaitu daview
The U.S. Solid Motorized Ball Valve is a robust solution for automated fluid control. Key features include:
- NPT Threading: Features 1/4 inch Stainless Steel NPT threading, ensuring compatibility with standard pipe systems. This is a full port valve.
- Zabala Voltage Barrutia: Operates effectively on 85-265V AC power.
- Eragiketa azkarra: Opens or closes the valve within 3-5 seconds.
- Energia eraginkorra: Once fully open or closed, the valve consumes minimal to no power, reducing the likelihood of overheating.
- 2-Wire Automatic Return: Simple wiring for automatic return to a closed position upon power loss.
- Iraunkortasuna: Designed for a long lifespan of 80,000-100,000 cycles.
- IP65 balorazioa: Provides protection against dust ingress and low-pressure water jets from any direction.

3.1. irudia: Aurrealdea view of the U.S. Solid 1/4 inch motorized ball valve, showing the blue actuator and stainless steel body.

3.2. irudia: Aldea view of the motorized ball valve, illustrating the blue actuator, stainless steel valve body, and the two-wire connection.
4. Zehaztapenak
| Zehaztapena | Balioa |
|---|---|
| Marka | AEB Solidoak |
| Modelo zenbakia | USS-MSV00052 |
| Materiala | Altzairu herdoilgaitza |
| Tamaina | 1/4 hazbete |
| liburukiatage | 85-265V AC |
| Konexio mota | NPT Threading, Full Port |
| Kablearen konfigurazioa | 2 Wire, Automatic Return |
| Operating Time (Open/Close) | 3-5 segundo |
| Funtzionamendu-presio maximoa | 1000 Pascal |
| Portu kopurua | 2 |
| Sarrera babesteko (IP) balorazioa | IP65 |
| Elementuaren neurriak (L x W x H) | 3.35 x 2.68 x 2.28 hazbete |
| Elementuaren pisua | 9.2 ontza |
| UPC | 888107088790 |

4.1. irudia: Technical drawing showing the dimensions of the motorized ball valve in millimeters, including length, height, and thread size.

4.2. irudia: Diagram illustrating the IP65 ingress protection rating for solids and liquids, and visual representations of normally closed, full port, normally open, and standard port valve configurations.
5. Instalazioa
Before installation, ensure the power supply is off and the system is depressurized. This valve is designed for NPT threaded connections.
- Hariak prestatu: Apply appropriate thread sealant (e.g., PTFE tape) to the male pipe threads. Wrap the tape clockwise around the threads, ensuring full coverage.
- Connect Valve: Carefully screw the valve onto the pipe ends. Tighten securely to prevent leaks, but do not overtighten.
- Kokalekua: Ensure the valve actuator is positioned to allow for easy access for wiring and future maintenance.
- Ikuskatu: After installation, visually inspect all connections for proper alignment and tightness.

5.1. irudia: Gertutik view of the 1/4 inch NPT threading on the valve, highlighting the full port design.

5.2. irudia: Visual guide demonstrating the application of Teflon tape to male pipe threads for a watertight seal, and the resulting threaded connection to the valve.
6. Kableatuen Diagrama
This valve features a 2-wire automatic return configuration. This means the valve will open when power is applied and automatically return to its closed position when power is removed.
- Konexioa: Connect the two wires from the valve to your 85-265V AC power source, typically through a switch.
- Eragiketa: When the circuit is closed (switch is ON), the valve will open and remain open. Once open, power consumption is nominal.
- Itzulera automatikoa: When the circuit is open (switch is OFF or power is lost), the valve will close. In this state, the valve is fully de-energized, consuming zero power.

6.1. irudia: Schematic diagram illustrating the 2-wire automatic return wiring for the motorized ball valve, showing how a switch controls the open and closed states.

6.2. irudia: Detailed wiring diagrams for 2-wire auto return valves, applicable for both DC and AC power sources, showing the open and closed states.
7. Funtzionamendua
The U.S. Solid Motorized Ball Valve operates based on the presence or absence of electrical power to its two-wire connection.
- Balbula irekitzeko: Apply 85-265V AC power to the valve's two wires. The internal motor will rotate the ball to the open position within 3-5 seconds. Once fully open, the motor de-energizes, and the valve remains open with minimal power consumption.
- Balbula ixteko: Remove the 85-265V AC power from the valve's two wires. The valve will automatically return to its fully closed position within 3-5 seconds. Once fully closed, the valve is completely de-energized.
This automatic return feature makes it suitable for applications where a default closed state is desired, especially in case of power interruption.
8. Mantentzea
The U.S. Solid Motorized Ball Valve is designed for long-term, reliable operation with minimal maintenance. However, periodic checks are recommended:
- Ikus-ikuskapena: Regularly inspect the valve and connections for any signs of leaks, corrosion, or physical damage.
- Konexio elektrikoak: Ensure all electrical connections are secure and free from moisture or damage.
- Actuator Function: Periodically cycle the valve (open and close) to ensure the actuator operates smoothly and fully.
- Garbiketa: Keep the exterior of the valve and actuator clean and free from debris.
For internal components, refer to qualified service personnel only.
9. Arazoak
If you encounter issues with your motorized ball valve, consider the following troubleshooting steps:
- Valve Not Opening/Closing:
- Check if power is correctly supplied to the valve (for opening) or completely removed (for closing).
- Egiaztatu liburukiatage matches the valve's rating (85-265V AC).
- Begiratu kableatua konexio solte edo kalterik dagoen ikusteko.
- Konexioetako ihesak:
- Ensure pipe threads were properly prepared with thread sealant (e.g., PTFE tape).
- Check if connections are tightened sufficiently. Do not overtighten, as this can damage threads.
- Ezohiko zarata funtzionamenduan:
- Ensure the valve is not obstructed internally or externally.
- Zarata jarraitzen badu eta errendimenduari eragiten badio, jarri harremanetan bezeroarentzako arreta-zerbitzuarekin.
If these steps do not resolve the issue, please contact U.S. Solid customer support.
10. Bermea eta Laguntza
U.S. Solid stands by the quality of its products. This motorized ball valve is backed by a 1-year warranty or money-back promise, ensuring customer satisfaction. For technical assistance, warranty claims, or any product-related inquiries, please contact U.S. Solid customer support through the retailer where the product was purchased or visit the official U.S. Solid webgunea.