Elitech ILD-100H

Elitech ILD-100H HVAC hozgarri-ihes-detektagailua erabiltzailearen eskuliburua

Model: ILD-100H | Brand: Elitech

1. Sarrera eta Overview

The Elitech ILD-100H is an advanced HVAC refrigerant leak detector designed for precise and efficient detection of various halogenated refrigerants. Utilizing a heated diode sensor, it offers enhanced accuracy and reliability compared to traditional sensors. This manual provides detailed instructions for the proper setup, operation, maintenance, and troubleshooting of your ILD-100H detector, ensuring optimal performance and longevity.

This device is suitable for detecting a wide range of refrigerants, including CFCs, HFCs, HCFCs, HCs, HFOs, and mixed refrigerants such as R11, R22, R404a, R410a, R600a, R1234yf, and various blends like AZ-50, HP62, and MP39. It boasts an immediate response time, making leak detection quick and effective.

2. Ezaugarri nagusiak

  • Heated Diode Sensor: Provides superior accuracy for all halogenated refrigerants, ensuring reliable detection results.
  • TFT pantaila: The innovative TFT screen offers clear and easy-to-read information, including sensitivity levels, leakage alerts, and battery status, enhancing operational clarity.
  • Sentsibilitate handia: Features adjustable sensitivity with High, Medium, and Low levels. The maximum sensitivity reaches up to 0.1 oz/yr, allowing for the detection of even minute leaks.
  • Eragiketa azkarra: Equipped with two intuitive buttons on the front panel for rapid adjustment of sensitivity and direct muting of the buzzer, simplifying user interaction.
  • Broad Refrigerant Compatibility: Capable of detecting all types of halogenated refrigerants, including HFCs (R134a, R410A, R407C, R417A, R404A, R507, R23, R508A, R508B, R152A, R32), HCFCs (R22, R123, R124, R141b, R142b, R402A, R402B, R408A, R409A), CFCs (R11, R12, R13, R502, R503), PFCs (PFC-14, PFC-116, PFC-218), and HFOs (R-1234yf), as well as HCs (R50, R170, R290, R600, R600A, R1150, R1270).
Elitech ILD-100H Halogen Leak Detector highlighting adjustable sensitivity, audible & light alarm, immediate response, and two different modes.

2.1 Irudia: Gainetikview of Elitech ILD-100H key features.

3. Product Components and Dimensions

Elitech ILD-100H with labeled components including flexible probe, UV LED, filter components, display screen, buttons, and buzzer.

Figure 3.1: Labeled components of the Elitech ILD-100H.

Elitech ILD-100H dimensions showing 7.9 inches height, 3.3 inches width, 1.5 inches depth, and a 14-inch probe length. Also lists max sensitivity, response time, battery, and compliance standards.

Figure 3.2: Physical dimensions and key performance specifications.

4. Konfigurazioa

  1. Despaketatzea: Carefully remove the Elitech ILD-100H and all accessories from the packaging. Inspect for any signs of damage.
  2. Bateria kargatzea: The device includes a Lithium Metal battery. Before first use, ensure the battery is fully charged. Connect the appropriate charging cable (not specified in data, assume standard USB-C based on reviews) to the device and a power source. The TFT screen will indicate charging status.
  3. Sensor Preparation: Ensure the flexible probe and filter components are securely attached. The heated diode sensor requires a brief warm-up period after powering on.
Elitech ILD-100H Refrigerant Leak Detector, a handheld device with a flexible probe and a digital display.

Figure 4.1: Elitech ILD-100H ready for setup.

5. Funtzionamendu-argibideak

  1. Piztu: Press the 'ON/OFF' button to power on the device. The TFT screen will illuminate and display a warm-up countdown.
  2. Beroketa: Allow the device to complete its warm-up cycle (typically 20 seconds as seen in image). This ensures the heated diode sensor reaches optimal operating temperature for accurate detection.
  3. Hautatu Sentikortasuna: Use the 'SENS' button to cycle through the sensitivity levels: High (H), Medium (M), and Low (L). Higher sensitivity is recommended for detecting smaller leaks or for initial scanning.
  4. Ihesak hautematea: Slowly move the flexible probe around suspected leak areas. The device will provide visual alerts on the TFT screen (e.g., bar graph, curve display) and an audible alarm when a leak is detected. The intensity of the alarm and display will increase with higher leak concentrations.
  5. Pinpoint vs. Curve Display: The TFT screen offers two display modes. The 'Pinpoint Display' helps in finding the exact leak location, while the 'Curve Display' assists in quickly identifying the general leak area.
  6. Mute Buzzer: Press the 'MUTE' button to silence the audible alarm if needed.
  7. Itzali: Press and hold the 'ON/OFF' button to power off the device after use.
Elitech ILD-100H display modes showing Pinpoint Display for exact leak location and Curve Display for general leak area.

Figure 5.1: Understanding the Pinpoint and Curve Display modes for leak identification.

Elitech ILD-100H detecting various halogenated refrigerants including HFC, HCFC, CFC, PFC, HFO, and HC types.

Figure 5.2: The ILD-100H's capability to detect a wide range of halogenated refrigerants.

5.1. bideoa: Over batview of Elitech's AI HVAC/R tools, demonstrating the advanced capabilities and applications of their products, including the ILD-100H leak detector in action.

6. Mantentzea

  • Garbiketa: Regularly wipe the exterior of the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Sensor and Filter Maintenance: The device features filter components (as shown in Figure 3.1). Refer to the full user manual (PDF link provided in product data) for specific instructions on cleaning or replacing the sensor and filter to maintain optimal performance.
  • Biltegiratzea: Store the detector in a cool, dry place away from direct sunlight and extreme temperatures when not in use.

7. Arazoak

If you encounter issues with your Elitech ILD-100H, consider the following common troubleshooting steps:

  • Gailua ez da pizten: Ensure the battery is fully charged. If the issue persists, try connecting the charger to confirm power supply.
  • Inaccurate Readings/No Detection: Check the sensor and filter for any obstructions or damage. Ensure the device has completed its warm-up cycle. Adjust sensitivity settings to a higher level if necessary.
  • Portaera irregularra: Ensure the device is not exposed to strong electromagnetic interference. Try restarting the device.

For persistent issues or complex problems, please refer to the comprehensive user manual or contact Elitech customer support.

8. Zehaztapenak

AtributuaXehetasuna
MarkaElitech
Modelo zenbakiaILD-100H
EstiloaHeated Diode Sensor
Energia iturriaBateriaren bidez
KoloreaHeated Diode Sensor Ild-100h
Produktuaren neurriak (L x W x H)1.5" x 3.3" x 7.9"
Elementuaren pisua2.46 kilo
Alarma motaEntzungarria
Funtzionamenduaren hezetasunaehuneko 85
Goiko Tenperaturaren Balorazioa20 gradu Celsius
Sentsore motaIR
MaterialaPlastikoa
Max sentsibilitatea0.1 oz/yr
Erantzun DenboraImmediate (within 1s)
Bateria motaLithium Ion (1 Lithium Metal battery included)
Bateria Edukiera3.7V 3000mAh
ErabileraHVAC systems, refrigerant leak detection
Betetze-arauakEN14624.5AE-162, SAE-2791, SAE-2913, CE
UPC704529988930, 704529989043

9. Bermea eta Laguntza

The Elitech ILD-100H Refrigerant Leak Detector comes with a 1 urteko bermea erosketa-datatik aurrera.

For any technical assistance, product inquiries, or warranty claims, Elitech offers 7x24 customer services. Please refer to the official Elitech website or the full user manual for contact details.

You can also download the complete user manual in PDF format for more detailed information: Deskargatu erabiltzailearen eskuliburua (PDF)

Erlazionatutako dokumentuak - ILD-100H

Aurreview Elitech WJL-6000S Corona detektagailuaren erabiltzailearen eskuliburua
Elitech WJL-6000S Corona Detektagailuaren erabiltzailearen eskuliburua, hainbat sistematan hozgarri-ihesak detektatzeko funtzionamenduari, detekzioari, arazoak konpontzeari eta mantentze-lanei buruzko argibide zehatzak ematen dituena.
Aurreview Elitech ILD serie infragorri hozgarrien ihes-detektagailuaren erabiltzailearen eskuliburua
Elitech ILD serieko infragorri hozgarri-ihesak detektatzeko (ILD-100, ILD-200, ILD-300) erabiltzailearen eskuliburu osoa, zehaztapenak, funtzionamendua, mantentze-lanak eta ezaugarriak biltzen dituena. Ikasi hozgarri-ihesak modu eraginkorrean detektatzen gailu aurreratu honekin.
Aurreview Elitech ILD-100/ILD-200/ILD-300 Infragorri Ihes Detektagailuaren Erabiltzaile Eskuliburua
Elitech ILD serieko infragorri hozgarri-ihesen detektagailuen (ILD-100, ILD-200, ILD-300) erabiltzailearen eskuliburua. Informazio zehatza ematen du funtzionamenduari, zehaztapenei, ezaugarriei eta mantentze-lanei buruz, hozgarri-ihesak zehatz-mehatz detektatzeko.
Aurreview Elitech LD-100 Berotutako Diodo Hozgarri Ihes Detektagailuaren Erabiltzaile Eskuliburua
Elitech LD-100 Berotutako Diodo Hozgarri Ihes Detektagailuaren erabiltzailearen eskuliburua, bere ezaugarriak, funtzionamendua eta mantentze-lanak zehaztuz.
Aurreview Elitech IR-200 Infragorri eta Berotutako Diodo Ihes Detektagailuaren Erabiltzaile Eskuliburua
Elitech IR-200 detektagailuaren erabiltzailearen eskuliburu osoa, infragorri eta berotutako diodo teknologiak dituen sentsore bikoitzeko ihes-detektagailua. Ikasi bere zehaztapenak, funtzionamendua, mantentze-lanak eta hozgarri-ihesak detektatzeko ezaugarriak.
Aurreview Elitech MS-100 kolektore digitala: erabiltzailearen eskuliburua eta zehaztapenak
Elitech MS-100 kolektore digitalaren gida osoa, bere ezaugarriak, zehaztapen teknikoak, funtzionamendua, segurtasun-argibideak eta arazoak konpontzea azaltzen dituena. Ikasi gailua nola erabili presio eta tenperatura neurketetarako, ihes-probetarako, huts-prozesuetarako eta datuak erregistratzeko Elitech Tools aplikazioarekin.