REYAX RYLR896

REYAX RYLR896 Lora Module User Manual

Model: RYLR896

1. Sarrera

The REYAX RYLR896 is a Lora module designed for long-range, low-power wireless communication. It integrates the Semtech SX1276 chip and communicates via a UART interface using AT commands. This module operates in the 868MHz and 915MHz frequency bands, making it suitable for various IoT and M2M applications requiring extended range and robust connectivity.

This manual provides essential information for the proper setup, operation, and maintenance of your RYLR896 module.

2. Ezaugarriak

  • Semtech SX1276 Lora Transceiver
  • UART Interface for easy communication
  • Supports 868MHz and 915MHz frequency bands
  • AT Command set for configuration and control
  • Antena integratua
  • Energia-kontsumo txikia
  • FCC and NCC certified

3. Zehaztapenak

ZehaztapenaBalioa
Modelo zenbakiaRYLR896
Produktuaren neurriak1.67 x 0.72 x 0.22 hazbete
Elementuaren pisua0.106 ontza
FabrikatzaileaREYAX
Antena MotaRadio (Integrated)
Kanal kopurua208
Inpedantzia50 ohmio
Gehienezko irismena15000 metro
UPC755874948070, 644824865713

4. Pinaren Deskribapena

The RYLR896 module features several pins for power, communication, and control. Understanding these pins is crucial for proper integration.

REYAX RYLR896 Lora Module Pin Description

Irudia: Pinout diagram for the REYAX RYLR896 Lora module, showing GND, TXD, RXD, NRST, and VDD connections.

  • GND: Lur-konexioa.
  • TXD: Transmit Data pin. Connects to the RXD pin of your microcontroller or UART bridge.
  • RXD: Receive Data pin. Connects to the TXD pin of your microcontroller or UART bridge.
  • NRST: Reset pin. Can be used to reset the module.
  • VDD: Power supply input. Ensure the voltage does not exceed 3.6VDC to prevent damage.

5. Konfigurazioa

To begin using the RYLR896 module, you will need a USB to UART bridge (e.g., REYAX RYLS135) to interface with a computer or a microcontroller with a UART interface.

5.1. Hardware konexioa

  1. Konektatu GND pin of the RYLR896 module to the Ground of your UART bridge/microcontroller.
  2. Konektatu TXD pin of the RYLR896 module to the RXD pin of your UART bridge/microcontroller.
  3. Konektatu RXD pin of the RYLR896 module to the TXD pin of your UART bridge/microcontroller.
  4. Konektatu VDD pin of the RYLR896 module to a stable power supply (e.g., 3.3V). Warning: Do not exceed 3.6VDC on the VDD or transmit pin to avoid damaging the unit.
  5. Ensure the antenna is securely attached or integrated.
REYAX RYLR896 Lora Module Block Diagram

Irudia: Block diagram illustrating the connection between a processor and the RYLR896 module, highlighting TXD, RXD, and NRST lines.

5.2. Softwarearen konfigurazioa

Once connected, open a serial terminal program on your computer. Configure the serial port settings as follows:

  • Baud tasa: 9600 (default for the module's UART communication)
  • Datu-bitak: 8
  • Parekidetasuna: Bat ere ez
  • Gelditzeko bitak: 1
  • Fluxuaren kontrola: Bat ere ez

Ensure your serial terminal is configured to send commands with a Carriage Return (CR) and Line Feed (LF) termination (CRLF) for proper command recognition by the module.

6. Operating Instructions (AT Commands)

The RYLR896 module is controlled using a set of AT commands. These commands allow you to configure network parameters, send data, and manage the module's state.

Lora AT Command Guide for RYLR896

Irudia: Excerpt from the Lora AT Command Guide, showing basic commands for ADDRESS, NETWORKID, BAND, and PARAMETER.

6.1. Basic AT Commands

  • AT+ADDRESS=<address>
    Sets the module's unique address. This address identifies the transmitter or specified receiver. Example: AT+ADDRESS=1
  • AT+NETWORKID=<ID>
    Sets the ID of the Lora network. This is a group function; only modules with the same NETWORKID can communicate. Recommended values: 1-15. Example: AT+NETWORKID=5
  • AT+BAND=<frequency>
    Sets the center frequency of the wireless band (e.g., 868000000 for 868MHz or 915000000 for 915MHz). Both transmitter and receiver must use the same frequency. Example: AT+BAND=915000000
  • AT+PARAMETER=<SF>,<BW>,<CR>,<Preamble>
    Sets the RF wireless parameters. Both transmitter and receiver must use the same parameters.
    • SF (Spreading Factor): The larger the SF, the better the sensitivity, but transmission time will be longer.
    • BW (Bandwidth): The smaller the bandwidth, the better the sensitivity, but transmission time will be longer.
    • CR (Coding Rate): Error correction rate.
    • Hitzaurrea: Preamble length.
    Example: AT+PARAMETER=10,7,1,4
  • AT+SEND=<address>,<length>,<data>
    Sends data to a specified address. Example: AT+SEND=1,5,HELLO (sends "HELLO" to module with address 1).

For a complete list of AT commands and their detailed usage, refer to the official REYAX documentation.

7. Mantentzea

The RYLR896 module is a robust electronic component, but proper handling and care can extend its lifespan and ensure reliable operation.

  • Garbitasuna: Keep the module free from dust, dirt, and moisture. Use a soft, dry cloth for cleaning if necessary.
  • Elikatze-iturria: Always provide a stable and clean power supply within the specified voltage range (VDD max 3.6VDC). Over-voltage can permanently damage the module.
  • Manipulazioa: Avoid static discharge when handling the module. Use anti-static precautions.
  • Biltegiratzea: Store the module in a dry, cool environment, away from direct sunlight and extreme temperatures.

8. Arazoak

If you encounter issues with your RYLR896 module, consider the following troubleshooting steps:

  • Komunikaziorik ez:
    • Verify wiring: Ensure TXD and RXD are crossed correctly (module TXD to host RXD, module RXD to host TXD).
    • Check baud rate: Confirm your serial terminal's baud rate matches the module's default (9600) or configured baud rate.
    • Power supply: Ensure the module is receiving adequate and stable power within the 3.6VDC limit.
    • AT command termination: Commands require CRLF termination. Incorrect termination can lead to unrecognized commands.
  • Inconsistent Responses: Some users have reported inconsistent End-Of-Line (EOL) termination at very low baud rates (below 1200). Ensure your terminal is configured for CRLF.
  • Module Damage: Exceeding 3.6VDC on the transmit pin or supply voltage pin can damage the unit. Always double-check your voltage konexioak.
  • No Range/Poor Performance:
    • Ensure both modules have the same NETWORKID, BAND, and PARAMETER settings.
    • Check for physical obstructions or interference.
    • Verify antenna connection and integrity.
  • Module Not Responding After Sleep: If the module is put to sleep, some parameters might need to be re-initialized upon wake-up.

9. Arauzko informazioa

The REYAX RYLR896 module complies with relevant regulatory standards.

FCC Grant of Equipment Authorization for RYLR896

Irudia: FCC Grant of Equipment Authorization document for the RYLR896 module, showing FCC ID QLYRYLR896 and Grantee REYAX TECHNOLOGY CO., LTD.

FCC IDa: QLYRYLR896

Gailu honek FCC Arauen 15. zatia betetzen du. Funtzionamendua bi baldintza hauen menpe dago: (1) Gailu honek ez du interferentzia kaltegarririk eragin, eta (2) gailu honek jasotako edozein interferentzia onartu behar du, nahi ez den funtzionamendua eragin dezakeen interferentziak barne.

The output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators under the supervision of the Grantee. This transmitter is restricted for use with the specified antenna(s) tested in this application for certification and must not be co-located or operating in conjunction with any other antenna or transmitter within a host device, except in accordance with FCC multi-transmitter product procedures.

10. Bermea eta Laguntza

For warranty information and technical support, please refer to the official REYAX webwebgunera edo jarri harremanetan zure erosketa-puntuarekin. Gorde erosketa-agiria berme-erreklamazioetarako.

Bisita dezakezu REYAX Store on Amazon produktu eta informazio gehigarrirako.

Erlazionatutako dokumentuak - RYLR896

Aurreview REYAX Lora AT Command Guide - Configuration and Usage
Comprehensive guide to using AT commands for REYAX Lora modules, covering configuration, communication, and troubleshooting. Includes command syntax, parameters, and responses for models like RYLR405, RYLR406, RYLR895, RYLR896, and RYLR89H1. Essential for developers and engineers working with REYAX LoRa communication solutions.
Aurreview REYAX RYLR998/RYLR498 LoRa AT Command Guide - Technical Specification
Comprehensive guide to AT commands for REYAX RYLR998 and RYLR498 LoRa modules. Covers command syntax, parameters, RF settings, data transmission, and error codes.
Aurreview RYRR20W RFID Module Command Manual | REYAX Technology
Comprehensive command manual for the REYAX RYRR20W RFID module, detailing protocol formats, ISO/MIFARE/FeliCa card commands, sequence diagrams, and certification information. Includes FCC and NCC compliance details.
Aurreview RYRR30D AT Command Guide
This guide provides detailed information on using AT commands with the REYAX RYRR30D module for NFC applications, including sequences for Apple Wallet VAS and Google SmartTap passes, command sets, and certification information.
Aurreview REYAX RYRR20I_DELTA_V17 RFID Module User Manual - Specifications, Commands, and Certifications
Detailed user manual for the REYAX RYRR20I_DELTA_V17 13.56-MHz RFID module. Includes product overview, technical specifications, pin descriptions, command manual, flow charts, dimensions, and FCC/IC/NCC certification information.
Aurreview RYWB116 Embedded WLAN Software Programming Reference Manual
This document provides a comprehensive guide to the RYWB116 WiSeConnect module, detailing its architecture, boot-loader features, AT command modes, and supported host interfaces. It serves as a reference for implementing application software to control and operate the RYWB116 module, including Wi-Fi AT commands with parameters and expected responses.