U.S. Solid USS-DBS3-1

U.S. Solid 100g 0.001g Digital Analytical Balance Precision Scale

Model: USS-DBS3-1

Sarrera

This manual provides essential information for the proper operation and maintenance of your U.S. Solid Digital Analytical Balance. Please read this manual thoroughly before using the scale to ensure accurate measurements and prolong the life of the instrument. This precision scale is designed for laboratory and industrial applications requiring high accuracy measurements up to 100 grams with 0.001g readability.

Segurtasun Informazioa

  • Always operate the scale on a stable, level, and vibration-free surface.
  • Avoid placing the scale near strong electromagnetic fields, heat sources, or direct sunlight.
  • Do not overload the scale beyond its maximum capacity of 100g.
  • Keep the scale clean and free from dust, liquids, and corrosive substances.
  • Handle the draft shield and weighing pan with care to prevent damage.
  • Ensure the power adapter is correctly connected and use only the provided adapter.

Paketearen edukia

Egiaztatu elementu guztiak bertan daudela eta egoera onean daudela paketea desontziratzean.

  • U.S. Solid Digital Analytical Balance
  • Altzairu herdoilgaitzezko pisatzeko platera
  • Draft Shield (Windshield)
  • AC/DC korronte egokitzailea
  • Calibration Weight (typically 100g)
  • Erabiltzailearen eskuliburua (dokumentu hau)

Produktua amaituview

Familiarize yourself with the main components and controls of the analytical balance.

Goiena view of the U.S. Solid Digital Analytical Balance showing the control panel and draft shield.
1. irudia: Goikoa View of Analytical Balance. Irudi honek goiko aldea erakusten du view of the U.S. Solid Digital Analytical Balance, highlighting the control panel with its buttons and the transparent draft shield covering the weighing pan.
Diagram showing the control panel buttons: ON/OFF, UNIT, PCS, CAL, TARE/ZERO, and the Backlit LED Display, Draft Shield, SS Pan, and AC & DC Power Supply.
Figure 2: Control Panel and Key Components. This diagram labels the main buttons on the control panel including ON/OFF, UNIT, PCS (Counting Mode), CAL (Calibrate), and TARE/ZERO. It also points out the Backlit LED Display, Draft Shield, Stainless Steel (SS) Pan, and the AC & DC Power Supply connection.

Funtsezko osagaiak:

  • Pisatzeko platera: Stainless steel platform for placing items to be weighed.
  • Draft Shield: Transparent enclosure to protect the weighing pan from air currents, ensuring stable and accurate readings.
  • LCD pantaila: Backlit screen showing weight readings, units, and other operational information.
  • Kontrol-botoiak:
    • ON/OFF: Balantza pizten edo itzaltzen du.
    • UNITATEA: Cycles through available weighing units (g, ct, oz, lb, etc.).
    • PCS (Counting Mode): Pieza zenbatzeko funtzioa aktibatzen du.
    • CAL (Calibrate): Initiates the calibration process.
    • TARA/ZERO: Resets the display to zero, or tares the weight of a container.
  • Berdinketa-burbuila: Indicates if the scale is perfectly level.
  • Oin erregulagarriak: Used to level the scale.

Konfigurazioa

1. Placement and Leveling

For optimal accuracy, place the analytical balance on a firm, stable, and level surface, free from vibrations, drafts, and direct heat.

Aldea view of the U.S. Solid Digital Analytical Balance showing the leveling bubble.
Figure 3: Leveling Bubble. This image shows a close-up of the leveling bubble on the side of the scale, which helps ensure the device is perfectly horizontal for accurate measurements.
Diagram illustrating horizontal adjustment using leveling feet and the importance of environmental stability.
Figure 4: Horizontal Adjustment and Environmental Stability. This diagram illustrates how to adjust the leveling feet until the bubble is centered for proper horizontal adjustment. It also emphasizes the need for a stable, vibration-free environment, away from air currents and temperature changes, to maintain accuracy.
  1. Place the scale on a sturdy workbench or table.
  2. Adjust the four adjustable feet located at the bottom of the scale until the bubble in the leveling indicator is perfectly centered. This ensures the weighing mechanism is horizontal.

2. Energia-konexioa

Connect the provided AC/DC power adapter to the power input port on the scale and then plug it into a suitable electrical outlet.

3. Warm-up Time

After connecting power, allow the balance to warm up for at least 30 minutes before use. This stabilizes the internal components and ensures accurate measurements. For best results, keep the scale powered on during periods of frequent use.

Funtzionamendu-argibideak

1. Piztu/Itzali

  • Sakatu ON/OFF button to turn the scale on. The display will show a self-test sequence and then settle at 0.000g.
  • Eduki sakatuta ON/OFF botoia balantza itzaltzeko.

2. Kalibrazioa

Calibration is crucial for maintaining accuracy. It is recommended to calibrate the scale before first use, after moving it, or if you suspect inaccurate readings.

Diagram showing the calibration process with the CAL button and placement of calibration weight.
Figure 5: Calibration Process. This diagram illustrates the steps for calibration, including pressing the CAL button and placing the provided calibration weight on the weighing pan. The display will guide the user through the process.
  1. Ensure the weighing pan is empty and the draft shield is closed.
  2. Sakatu CAL button. The display will show "CAL" followed by the required calibration weight (e.g., "100.000g").
  3. Carefully place the specified calibration weight (e.g., 100g) onto the center of the weighing pan.
  4. Wait for the display to stabilize and show "PASS" or return to 0.000g, indicating successful calibration.
  5. Remove the calibration weight. The scale is now ready for use.

3. Pisatzea

  1. Ensure the scale is powered on and displays 0.000g. If not, press TARE/ZERO.
  2. Kontu handiz jarri pisatu beharreko elementua pisatzeko platera erdian.
  3. Close the draft shield to prevent air currents from affecting the reading.
  4. Read the stable weight displayed on the LCD.
  5. Kendu elementua zartaginetik.

4. Tara funtzioa

Tara funtzioak ontzi baten pisua kentzea ahalbidetzen du, beraz, edukiaren pisu garbia bakarrik neurtzen da.

  1. Place an empty container on the weighing pan. The display will show its weight.
  2. Sakatu TARE/ZERO button. The display will reset to 0.000g.
  3. Add the substance to be weighed into the container. The display will now show only the weight of the substance.
  4. To clear the tare, remove the container from the pan and press TARE/ZERO berriz.

5. Unitate Bihurketa

The scale supports multiple weighing units.

Diagram showing various measuring units available on the scale: g, ct, oz, ozt, lb, N, T, GN, dr, tlT, T/A/R.
Figure 6: Measuring Units. This diagram illustrates the different measuring units supported by the scale, including grams (g), carats (ct), ounces (oz), troy ounces (ozt), pounds (lb), Newtons (N), Tael (T), Grains (GN), Dram (dr), Tola (tlT), and T/A/R.
  • Sakatu UNITATEA button to cycle through the available weighing units (e.g., grams (g), carats (ct), ounces (oz), pounds (lb)).
  • The currently selected unit will be displayed on the LCD.

6. Piece Counting (PCS)

This function allows you to count a large number of identical items by weighing a sample.

Diagram showing the piece counting function with sample sizes: 10, 20, 50, 100, 150, 200, 250, 500.
Figure 7: Piece Counting Sample Sizes. This diagram illustrates the various sample sizes that can be used for the piece counting function, including 10, 20, 50, 100, 150, 200, 250, and 500 pieces.
  1. Place a known quantity of items (e.g., 10, 20, 50, 100 pieces) on the weighing pan.
  2. Sakatu PCS button. The display will show "PCS" and a number (e.g., "PCS 10").
  3. Sakatu UNITATEA botoia s hautatzekoample size that matches the number of items you placed on the pan.
  4. Sakatu PCS again to confirm the sample size. The display will now show the total count of items.
  5. Orain elementu gehiago gehi ditzakezu, eta balantzan kopuru osoa bistaratuko da.
  6. Zenbaketa modutik irteteko, sakatu PCS botoia berriro.

Mantentzea

1. Garbiketa

  • Deskonektatu beti korronte-egokigailua garbitu aurretik.
  • Wipe the scale's exterior with a soft, damp oihal. Ez erabili garbitzaile urratzailerik, disolbatzailerik eta ez murgildu balantza uretan.
  • The stainless steel weighing pan can be removed and cleaned separately with mild soap and water. Ensure it is completely dry before placing it back on the scale.
  • Clean the draft shield with a soft cloth to maintain visibility.

2. Biltegiratzea

  • Denbora luzez erabiltzen ez duzunean, gorde balantza giro-tenperaturan, leku lehor eta hautsik gabeko batean.
  • Keep the draft shield in place to protect the weighing mechanism.

Arazoak konpontzea

ArazoaKausa posibleaIrtenbidea
Display shows "Err" or unstable readings.Overload, unstable surface, strong air currents, electromagnetic interference, or internal error.
  • Ensure item weight is within capacity (max 100g).
  • Place scale on a stable, level surface.
  • Close the draft shield.
  • Move scale away from electronic devices.
  • Eskalatu berriro kalibratu.
  • Restart the scale.
Irakurketa okerrak.Not calibrated, unstable environment, insufficient warm-up time, or dirty pan.
  • Egin kalibrazioa.
  • Ensure scale is level and on a stable surface.
  • Allow 30 minutes warm-up time.
  • Clean the weighing pan.
  • Ensure no air currents are affecting the scale.
Eskala ez da pizten.No power, faulty adapter, or internal issue.
  • Check power adapter connection and wall outlet.
  • Ziurtatu pizteko botoia irmo sakatuta dagoela.
  • If using batteries (if applicable), check battery level.
Tara funtzioa ez dabil.Funtzionamendu okerra.
  • Ensure the container is placed on the pan before pressing TARE/ZERO.
  • Remove the container and press TARE/ZERO to clear previous tare.

Zehaztapenak

EzaugarriXehetasuna
MarkaAEB Solidoak
Modelo zenbakiaUSS-DBS3-1
Edukiera100 g
Readability / Accuracy0.001g / 1 mg
Bistaratzeko motaLCD atzeko argiarekin
Pisatzeko Unitateakg, ct, oz, lb, N, T, GN, dr, tlT, T/A/R
Elikatze HorniduraAC/DC Adapter (100-240V)
Pisatzeko plateraAltzairu herdoilgaitza
Produktuaren neurriak13.78 x 9.45 x 4.92 hazbete
Elementuaren pisua4.39 kilo

Bermea eta Laguntza

U.S. Solid products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please refer to the official U.S. Solid webwebgunera edo jarri harremanetan zuzenean bezeroarentzako arreta-zerbitzura. Gorde erosketa-agiria berme-erreklamazioetarako.

U.S. Solid Customer Service: Mesedez, bisitatu www.ussolid.com harremanetarako datuak eta laguntza baliabideak lortzeko.

Erlazionatutako dokumentuak - USS-DBS3-1

Aurreview U.S. Solid USS-DBS Analytical Balance Operating Manual
Comprehensive operating manual for the U.S. Solid USS-DBS series analytical balances, covering features, specifications, installation, usage, calibration, maintenance, troubleshooting, and RS232 interface.
Aurreview U.S. Solid USS-DBS Analytical Balance Operating Manual
Comprehensive operating manual for the U.S. Solid USS-DBS series analytical balance, covering features, specifications, installation, usage, maintenance, and troubleshooting.
Aurreview U.S. Solid USS-DBS82 Precision Balance Instruction Manual
Comprehensive instruction manual for the U.S. Solid USS-DBS82 Series Precision Balance, covering safety precautions, design, operation, technical specifications, and contact information.
Aurreview U.S. Solid USS-DBS Digital Balance Operating Manual
Comprehensive operating manual for U.S. Solid USS-DBS series digital balances, covering specifications, installation, usage, maintenance, and troubleshooting. Learn how to calibrate, tare, and use piece counting functions.
Aurreview U.S. Solid USS-DBS Analytical Balance Operating Manual
Comprehensive operating manual for the U.S. Solid USS-DBS Analytical Balance, detailing specifications, installation, operation, internal settings, maintenance, troubleshooting, and legal use restrictions.
Aurreview U.S. SOLID Analytical Balance Manual: Precision Weighing, Density & Dynamic Functions
Comprehensive instruction manual for U.S. SOLID 0.1 mg Analytical Balances, covering models like USS-DBS62 and USS-DBS63. Learn about precision weighing, density determination, dynamic weighing, calibration, operation, and troubleshooting for laboratory and industrial applications.