The Leviton LB260-ES is a 60A, 2-Pole Plug-On Smart Ground Fault Protection of Equipment (GFPE) Branch Circuit Breaker. This hydraulic magnetic breaker is designed for 120/240 VAC systems with a 10KA Interrupt Rating. It is suitable for applications up to 60A when using copper wire or 50A when using aluminum wire.
This smart circuit breaker integrates with the My Leviton app, providing advanced features for home energy management and enhanced safety.
2. Segurtasun informazioa
OHARRA: Installation and servicing of this circuit breaker must be performed by a qualified electrician in accordance with all national and local electrical codes. Failure to follow these instructions may result in serious injury or death.
- Always turn off the main power supply at the service panel before working on electrical circuits.
- Erabili babes pertsonaleko ekipamendu (BPE) egokia instalazioan zehar.
- Ensure proper wire sizing and torque specifications are met for all connections.
- Produktu honek Kaliforniako Estatuak minbizia eta jaiotzetiko akatsak edo bestelako ugalketa-kalteak eragiten dituztela ezagutzen dituen produktu kimikoak ditu (65. Proposamenaren abisua).

1. irudia: Aurrealdea view of the Leviton LB260-ES circuit breaker.
3. Produktuaren ezaugarriak
- Integrazio adimenduna: Integrated with the My Leviton app, this breaker provides insightful data on home energy consumption, enhanced safety, and whole-home solutions in conjunction with other smart Leviton products.
- Instalazio erraza: Leviton's design allows the entire Load Center to be wired at rough-in without any circuit breakers present. The plug-on design simplifies installation.
- Hydraulic Magnetic Technology: Precision trip technology ensures consistent operation from -40°C to 85°C (-40°F to 185°F) without re-rating.
- Segurtasun hobetua: Features patented reset lockout technology, preventing the breaker from resetting if ground or arc fault protection is compromised.
4. Konfigurazioa eta instalazioa
The Leviton LB260-ES circuit breaker is designed for quick and secure installation within a compatible Leviton Load Center. The plug-on design eliminates the need for additional wiring to the breaker itself, as connections are made directly on the panel's bus bars.
Instalazio urratsak:
- Ensure the main power to the load center is OFF.
- Prepare branch circuit wires (phase and neutral) by stripping insulation to the recommended length.
- Connect the branch phase and neutral wires directly to the designated terminals on the load center panel. This allows for neat wiring at rough-in without breakers in the way.
- Align the LB260-ES breaker with the appropriate slot in the load center.
- Firmly push the breaker onto the bus bar until it snaps securely into place. No additional wiring to the breaker is required.
- Verify all connections are secure and the breaker is properly seated.
- Once all breakers are installed and the panel cover is secured, restore main power.

2. irudia: Aldea view illustrating the plug-on mechanism of the circuit breaker.
Instalazio bideoa:
Video 1: This official Leviton video demonstrates the installation process and features of the Leviton Load Center and its plug-on circuit breakers, including wiring and smart capabilities.
5. Funtzionamendu-argibideak
The Leviton LB260-ES circuit breaker operates like a standard circuit breaker but includes smart functionalities accessible via the My Leviton app.
Eskuzko funtzionamendua:
- ON / OFF etengailua: To turn a circuit ON, push the switch to the 'ON' position. To turn it OFF, push the switch to the 'OFF' position.
- Jauzi egin duen etengailua: If the breaker trips due to an overload or fault, the switch will move to a central, tripped position. To reset, first move the switch fully to the 'OFF' position, then to the 'ON' position. If the breaker immediately trips again, there is still a fault on the circuit that needs to be addressed.
Smart Features (via My Leviton App):
To utilize the smart features, download the My Leviton app and connect your Leviton Load Center and smart breakers according to the app's instructions.
- Energiaren jarraipena: View real-time energy consumption for individual circuits or the entire home. Track usage patterns over time to identify energy-saving opportunities.
- Urruneko kontrola: Remotely turn circuits ON or OFF from your smartphone or tablet.
- Anomaly Notifications: Receive alerts for electrical anomalies, such as unexpected power draws or circuit trips, directly to your device.
- Auto-probaren funtzionaltasuna: GFPE breakers feature self-test capabilities to ensure proper operation. The app may provide status updates on these tests.
6. Mantentzea
Leviton circuit breakers are designed for long-term reliability with minimal maintenance. However, periodic checks are recommended.
- Ikus-ikuskapena: Periodically inspect the circuit breaker and load center for any signs of damage, discoloration, or loose connections.
- GFPE Test: GFPE devices should be tested monthly. Press the 'TEST' button on the breaker. The breaker should trip immediately. Reset the breaker by moving the switch to 'OFF' then 'ON'. If the breaker does not trip or reset, it may be faulty and should be replaced by a qualified electrician.
- Garbiketa: Keep the load center area clean and free from dust and debris. Do not use liquids to clean inside the load center.
7. Arazoak
If you encounter issues with your Leviton LB260-ES circuit breaker, refer to the following common troubleshooting steps:
| Arazoa | Kausa posiblea | Irtenbidea |
|---|---|---|
| Breaker maiz bidaiatzen du | Overload, short circuit, or ground fault. | Unplug appliances from the circuit. Reset the breaker. If it trips again, consult a qualified electrician to identify and fix the fault. |
| Etengailua ez da berrezartzen | Persistent fault, or patented reset lockout engaged. | Ensure the switch is moved fully to 'OFF' before attempting to reset to 'ON'. If it still doesn't reset, a fault is present or the breaker is damaged. Consult a qualified electrician. |
| No energy data in My Leviton app | No internet connection, app not configured, or data hub issue. | Check your home's internet connection. Ensure the Leviton Load Center data hub is properly installed and connected. Verify app configuration and breaker pairing. |
| GFPE test button does not trip breaker | Faulty GFPE mechanism. | The breaker may be defective. It should be replaced immediately by a qualified electrician. |
For further assistance, refer to the My Leviton app's help section or contact Leviton customer support.
8. Zehaztapenak
| Zehaztapena | Balioa |
|---|---|
| Marka | Leviton |
| Modelo zenbakia | LB260-ES |
| Egungo balorazioa | 60 Amps |
| Polo kopurua | 2 |
| liburukiatage | 120/240 Volt korronte alternoa |
| Zirkuitu-eten mota | GFPE (Ground Fault Protection of Equipment) |
| Muntatze Mota | Plug-in Muntaia |
| Etenaren balorazioa | 10KA |
| Funtzionamendu-tenperatura | -40 °C eta 85 °C (-40 °F eta 185 °F) |
| Elementuaren pisua | 13.4 ontza |
| Produktuaren neurriak | 4 x 2.5 x 3.9 hazbete |
9. Bermea eta Laguntza
Bermearen informazioa:
This Leviton LB260-ES circuit breaker is covered by a 10 urteko berme mugatua. For specific terms and conditions, please refer to the warranty documentation included with your product or visit the official Leviton webgunea.
Bezeroarentzako laguntza:
For technical assistance, troubleshooting, or warranty claims, please contact Leviton Customer Support. You can find contact information on the official Leviton website or within the My Leviton app.
Leviton Official Webgunea: www.leviton.com