1. Produktua amaitu daview
The PCE-423N Air Flow Meter is a versatile instrument designed for precise measurement of air speed, volume flow, and temperature. Its compact design and extendable telescopic probe allow for measurements in various environments, including hard-to-reach areas. Equipped with a data memory for 10,000 measuring points and a Micro-USB interface, it facilitates efficient data collection and transfer.

Figure 1: PCE-423N Air Flow Meter with its telescopic probe fully extended, showcasing its compact display unit and sensor tip.
Ezaugarri nagusiak:
- Measuring range up to 30 m/s (98 ft/s) for air speed.
- Bateria kargagarri integratua, eramangarriki erabiltzeko.
- Data memory for up to 10,000 measuring points.
- Data export in CSV format via Micro-USB.
- Extendable telescopic probe (210 ... 426 mm / 8.2 ... 16.7") for flexible application.
- 2" LCD display (176 x 220 pixels) for clear readings.
2. Konfigurazioa eta hasierako erabilera
2.1 Desontziratzea eta ikuskatzea
Carefully unpack the PCE-423N Air Flow Meter and all included accessories. Verify that the following items are present:
- 1 x Air Flow Meter PCE-423N
- 1 x Mikro-USB kablea
- 1 x Instruction manual (this document)
Inspect the device for any visible damage. If any components are missing or damaged, contact PCE Instruments support immediately.
2.2 Bateria kargatzea
Before first use, fully charge the internal 1000 mAh battery. Connect the supplied Micro-USB cable to the device's Micro-USB port and the other end to a compatible 5V DC, 1A power source (e.g., a computer USB port or a USB wall adapter).

2. irudia: Aldea view of the PCE-423N displaying the Micro-USB port, used for charging and data transfer.
The charging indicator on the display will show the charging status. A full charge typically takes several hours.
2.3 Extending the Telescopic Probe
The PCE-423N features an extendable telescopic probe. To extend, gently pull the probe away from the main unit until it reaches the desired length. The probe can extend from 210 mm (8.2 inches) to 426 mm (16.7 inches). Ensure the probe is securely locked at the desired length before taking measurements.

3. irudia: hurbileko planoa view of the telescopic probe, showing measurement markings for precise extension.
2.4 Piztu/Itzaltzea
Press and hold the power button (usually marked with a power symbol) to turn the device on or off. The 2" LCD display will illuminate upon startup.
3. Funtzionamendu-argibideak
3.1 Bistaratuview
The LCD display provides real-time measurement data and device status. Key information displayed includes:
- Current measurement value (e.g., air speed, volume flow, temperature).
- Measurement units (e.g., m/s, ft/min, m³/h, CFM, °C, °F).
- Bateriaren mailaren adierazlea.
- Date and time (if applicable).

4. irudia: Xehetasuna view of the PCE-423N's LCD display, showing real-time air speed (V) and temperature (T) readings.
3.2 Neurketa moduak
The PCE-423N supports various measurement modes. Use the mode selection buttons (refer to the device's button layout) to switch between:
- Airearen abiadura: Measures air velocity in m/s or ft/min.
- Volume Flow: Calculates air volume flow in m³/h or CFM. Ensure correct duct area input if required by the device.
- Tenperatura: Measures air temperature in °C or °F.
For accurate air speed and volume flow measurements, ensure the sensor tip is positioned correctly within the airflow. The sensor tip is located at the end of the telescopic probe.

Figure 5: Close-up of the hot-wire sensor tip, which is crucial for accurate air flow measurements.
3.3 Data Memory and Transfer
The device can store up to 10,000 measuring points. Refer to the on-screen menu for options to save data manually or configure automatic logging intervals. Saved data can be exported in CSV format.
To transfer data to a computer:
- Connect the PCE-423N to your computer using the Micro-USB cable.
- The device should appear as a removable storage device.
- Kokatu CSV files containing your measurement data and copy them to your computer.
3.4 Using the Tripod Bracket
The PCE-423N is equipped with a 3/8" tripod bracket on its back, allowing for stable, hands-free measurements, especially useful for long-term monitoring or in specific setups.

6. Irudia: Atzealdea view of the PCE-423N, highlighting the 3/8" tripod bracket for stable positioning during measurements.
4. Mantentzea eta Zainketa
4.1 Garbiketa
Gailua garbitzeko, erabili zapi leun eta lehor bat. Zikinkeria egoskorra bada, garbitu zapi pixka bat.amp cloth with mild detergent can be used, ensuring no liquid enters the device openings. Do not use abrasive cleaners, solvents, or strong chemicals, as these can damage the casing edo pantaila.
The sensor tip is delicate. Clean it gently with a soft brush or compressed air to remove dust or debris. Avoid touching the sensor element directly.
4.2 Biltegiratzea
When not in use, store the PCE-423N in a dry, cool place, away from direct sunlight and extreme temperatures. The recommended storage conditions are -10 ... 60 °C (14 ... 140 °F) with less than 85% relative humidity, non-condensing. Retract the telescopic probe fully before storage to prevent damage.
4.3 Bateria zaintzea
To prolong battery life, avoid fully discharging the battery frequently. If storing the device for an extended period, charge the battery to approximately 50% and recharge every few months to prevent deep discharge.
5. Arazoak
5.1 Gailua ez da pizten
- Egiaztatu bateria: Ensure the battery is sufficiently charged. Connect the device to a power source using the Micro-USB cable and allow it to charge for at least 30 minutes before attempting to power on again.
- Pizteko botoia: Ensure the power button is pressed firmly and held for a few seconds.
5.2 Irakurketa zehaztugabeak
- Sentsorearen garbitasuna: Ensure the sensor tip is clean and free from dust or debris. A dirty sensor can lead to incorrect readings.
- Zundaren posizioa: Verify that the telescopic probe and sensor tip are correctly positioned within the airflow and not obstructed.
- Ingurumen-baldintzak: Ensure operating conditions are within the specified range (0 ... 50 °C / 32 ... 122 °F, <85 % RH, non-condensing).
- Kalibrazioa: If readings remain consistently inaccurate, the device may require recalibration. Contact PCE Instruments support for calibration services.
5.3 Datuen transferentzia arazoak
- Kable konexioa: Ensure the Micro-USB cable is securely connected to both the device and the computer. Try a different USB port on your computer.
- Kableen osotasuna: Try a different Micro-USB cable to rule out a faulty cable.
- Ordenagailuaren aitorpena: Check your computer's device manager to see if the PCE-423N is recognized. You may need to update USB drivers on your computer.
6. Zehaztapen Teknikoak
| Parametroa | Zehaztapena |
|---|---|
| Speed Measuring Range | 0.00 ... 30.00 m/s 0.0 ... 5905.5 ft/min |
| Abiadura Ebazpena | 0.01 m/s 0.1 oin/min |
| Abiaduraren zehaztasuna | ±0.10 m/s or ±5% of full scale at 0 ... 5 m/s ±0.30 m/s or ±5% of full scale at 5 ... 30 m/s (handiagoa dena) |
| Volume Flow Measuring Range | 0.0 ... 339120.0 m³/h 0.0 ... 99598.0 CFM |
| Volume Flow Resolution | 0.1 m³/h 0.1 CFM |
| Tenperatura neurtzeko tartea | 0 ... 50 °C 32 ... 122 °F |
| Tenperatura Ebazpena | 0.1 °C 0.1 °F |
| Tenperaturaren zehaztasuna | ±1 °C ±1.8 °F |
| Telescopic Probe Length | 210 ... 426 mm / 8.2 ... 16.7" |
| Telescopic Probe Diameter | 12 mm / 0.47" |
| Memoria | 10,000 neurketa puntu |
| File Formatua | CSV |
| Interfazea | Mikro-USB |
| Parentesia | 3/8" tripod bracket |
| Bistaratzea | 2" LCD display, 176 x 220 pixels |
| Neurketa Tasa | 1 Hz |
| Elikatze iturria (Bateria) | Internal 1000 mAh battery |
| Power Supply (External) | 5 V DC, 1 A |
| Funtzionamendu Baldintzak | 0 ... 50 °C (32 ... 122 °F), <85 % RH, non-condensing |
| Biltegiratzeko baldintzak | -10 ... 60 °C (14 ... 140 °F), <85 % RH, non-condensing |
| Dimensions (without probe) | 145 x 50 x 35 mm / 5.7 x 1.9 x 1.3" |
| Pisua | 156 g / 5.5 oz |
7. Bermea eta Laguntza
PCE Instruments provides a standard warranty for the PCE-423N Air Flow Meter against defects in materials and workmanship under normal use. The specific terms and duration of the warranty may vary by region. Please refer to the warranty card included with your product or visit the official PCE Instruments webbermearen informazio zehatza lortzeko gunea.
For technical support, troubleshooting assistance, or warranty claims, please contact PCE Instruments customer service. You can find contact information on the official PCE Instruments webgunearen bidez edo erosketa puntuaren bidez.
PCE Instruments US: Visit their Amazon Store